Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation
This work evidences the suitability of applying a single twisted nematic liquid-crystal (TN-LC) device to obtain dynamic polarimeters with high accuracy and repeatability. Different Stokes polarimeter setups based on a TN-LC device are optimized, leading to the minimization of the noise propagated f...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | JOUR |
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_1559128X_v50_n28_p5437_Peinado |
Aporte de: |
id |
todo:paper_1559128X_v50_n28_p5437_Peinado |
---|---|
record_format |
dspace |
spelling |
todo:paper_1559128X_v50_n28_p5437_Peinado2023-10-03T16:26:07Z Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation Peinado, A. Lizana, A. Vidal, J. Iemmi, C. Campos, J. Light sources Liquid crystal displays Liquid crystals Nematic liquid crystals Polarimeters Elliptical retarder Intensity measurements Noise propagation States of polarizations Stokes polarimeter Stokes vector calculation Twisted nematic liquid crystal devices Twisted nematic liquid crystals Light emitting diodes This work evidences the suitability of applying a single twisted nematic liquid-crystal (TN-LC) device to obtain dynamic polarimeters with high accuracy and repeatability. Different Stokes polarimeter setups based on a TN-LC device are optimized, leading to the minimization of the noise propagated from intensity measurements to the Stokes vector calculations. To this aim, we revise the influence of working out of normal incidence and of performing a double pass of the light beam through the LC device. In addition, because transmissive TN-LC devices act as elliptical retarders, an extra study is performed. It analyzes the influence of projecting the light exiting from the TN-LC device over elliptical states of polarization. Finally, diverse optimized polarimeters are experimentally implemented and validated by measuring different states of partially and fully polarized light. The analysis is conducted both for monochromatic (He-Ne laser) and LED light sources, proving the potential of polarimeters based on a single TN-LC device. © 2011 Optical Society of America. Fil:Iemmi, C. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_1559128X_v50_n28_p5437_Peinado |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
Light sources Liquid crystal displays Liquid crystals Nematic liquid crystals Polarimeters Elliptical retarder Intensity measurements Noise propagation States of polarizations Stokes polarimeter Stokes vector calculation Twisted nematic liquid crystal devices Twisted nematic liquid crystals Light emitting diodes |
spellingShingle |
Light sources Liquid crystal displays Liquid crystals Nematic liquid crystals Polarimeters Elliptical retarder Intensity measurements Noise propagation States of polarizations Stokes polarimeter Stokes vector calculation Twisted nematic liquid crystal devices Twisted nematic liquid crystals Light emitting diodes Peinado, A. Lizana, A. Vidal, J. Iemmi, C. Campos, J. Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation |
topic_facet |
Light sources Liquid crystal displays Liquid crystals Nematic liquid crystals Polarimeters Elliptical retarder Intensity measurements Noise propagation States of polarizations Stokes polarimeter Stokes vector calculation Twisted nematic liquid crystal devices Twisted nematic liquid crystals Light emitting diodes |
description |
This work evidences the suitability of applying a single twisted nematic liquid-crystal (TN-LC) device to obtain dynamic polarimeters with high accuracy and repeatability. Different Stokes polarimeter setups based on a TN-LC device are optimized, leading to the minimization of the noise propagated from intensity measurements to the Stokes vector calculations. To this aim, we revise the influence of working out of normal incidence and of performing a double pass of the light beam through the LC device. In addition, because transmissive TN-LC devices act as elliptical retarders, an extra study is performed. It analyzes the influence of projecting the light exiting from the TN-LC device over elliptical states of polarization. Finally, diverse optimized polarimeters are experimentally implemented and validated by measuring different states of partially and fully polarized light. The analysis is conducted both for monochromatic (He-Ne laser) and LED light sources, proving the potential of polarimeters based on a single TN-LC device. © 2011 Optical Society of America. |
format |
JOUR |
author |
Peinado, A. Lizana, A. Vidal, J. Iemmi, C. Campos, J. |
author_facet |
Peinado, A. Lizana, A. Vidal, J. Iemmi, C. Campos, J. |
author_sort |
Peinado, A. |
title |
Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation |
title_short |
Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation |
title_full |
Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation |
title_fullStr |
Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation |
title_full_unstemmed |
Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation |
title_sort |
optimized stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation |
url |
http://hdl.handle.net/20.500.12110/paper_1559128X_v50_n28_p5437_Peinado |
work_keys_str_mv |
AT peinadoa optimizedstokespolarimetersbasedonasingletwistednematicliquidcrystaldevicefortheminimizationofnoisepropagation AT lizanaa optimizedstokespolarimetersbasedonasingletwistednematicliquidcrystaldevicefortheminimizationofnoisepropagation AT vidalj optimizedstokespolarimetersbasedonasingletwistednematicliquidcrystaldevicefortheminimizationofnoisepropagation AT iemmic optimizedstokespolarimetersbasedonasingletwistednematicliquidcrystaldevicefortheminimizationofnoisepropagation AT camposj optimizedstokespolarimetersbasedonasingletwistednematicliquidcrystaldevicefortheminimizationofnoisepropagation |
_version_ |
1782028539806089216 |