A semi-automatic method for positioning a femoral bone reconstruction for strict view generation.
In this paper we present a semi-automatic method for femoral bone positioning after 3D image reconstruction from Computed Tomography images. This serves as grounding for the definition of strict axial, longitudinal and anterior-posterior views, overcoming the problem of patient positioning biases in...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | JOUR |
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_1557170X_v_n_p5608_Milano |
Aporte de: |
id |
todo:paper_1557170X_v_n_p5608_Milano |
---|---|
record_format |
dspace |
spelling |
todo:paper_1557170X_v_n_p5608_Milano2023-10-03T16:25:39Z A semi-automatic method for positioning a femoral bone reconstruction for strict view generation. Milano, F. Ritacco, L. Gomez, A. Gonzalez Bernaldo de Quiros, F. Risk, M. article automation computer assisted tomography femur human image processing methodology patient positioning radiography Automation Femur Humans Image Processing, Computer-Assisted Patient Positioning Tomography, X-Ray Computed In this paper we present a semi-automatic method for femoral bone positioning after 3D image reconstruction from Computed Tomography images. This serves as grounding for the definition of strict axial, longitudinal and anterior-posterior views, overcoming the problem of patient positioning biases in 2D femoral bone measuring methods. After the bone reconstruction is aligned to a standard reference frame, new tomographic slices can be generated, on which unbiased measures may be taken. This could allow not only accurate inter-patient comparisons but also intra-patient comparisons, i.e., comparisons of images of the same patient taken at different times. This method could enable medical doctors to diagnose and follow up several bone deformities more easily. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_1557170X_v_n_p5608_Milano |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
article automation computer assisted tomography femur human image processing methodology patient positioning radiography Automation Femur Humans Image Processing, Computer-Assisted Patient Positioning Tomography, X-Ray Computed |
spellingShingle |
article automation computer assisted tomography femur human image processing methodology patient positioning radiography Automation Femur Humans Image Processing, Computer-Assisted Patient Positioning Tomography, X-Ray Computed Milano, F. Ritacco, L. Gomez, A. Gonzalez Bernaldo de Quiros, F. Risk, M. A semi-automatic method for positioning a femoral bone reconstruction for strict view generation. |
topic_facet |
article automation computer assisted tomography femur human image processing methodology patient positioning radiography Automation Femur Humans Image Processing, Computer-Assisted Patient Positioning Tomography, X-Ray Computed |
description |
In this paper we present a semi-automatic method for femoral bone positioning after 3D image reconstruction from Computed Tomography images. This serves as grounding for the definition of strict axial, longitudinal and anterior-posterior views, overcoming the problem of patient positioning biases in 2D femoral bone measuring methods. After the bone reconstruction is aligned to a standard reference frame, new tomographic slices can be generated, on which unbiased measures may be taken. This could allow not only accurate inter-patient comparisons but also intra-patient comparisons, i.e., comparisons of images of the same patient taken at different times. This method could enable medical doctors to diagnose and follow up several bone deformities more easily. |
format |
JOUR |
author |
Milano, F. Ritacco, L. Gomez, A. Gonzalez Bernaldo de Quiros, F. Risk, M. |
author_facet |
Milano, F. Ritacco, L. Gomez, A. Gonzalez Bernaldo de Quiros, F. Risk, M. |
author_sort |
Milano, F. |
title |
A semi-automatic method for positioning a femoral bone reconstruction for strict view generation. |
title_short |
A semi-automatic method for positioning a femoral bone reconstruction for strict view generation. |
title_full |
A semi-automatic method for positioning a femoral bone reconstruction for strict view generation. |
title_fullStr |
A semi-automatic method for positioning a femoral bone reconstruction for strict view generation. |
title_full_unstemmed |
A semi-automatic method for positioning a femoral bone reconstruction for strict view generation. |
title_sort |
semi-automatic method for positioning a femoral bone reconstruction for strict view generation. |
url |
http://hdl.handle.net/20.500.12110/paper_1557170X_v_n_p5608_Milano |
work_keys_str_mv |
AT milanof asemiautomaticmethodforpositioningafemoralbonereconstructionforstrictviewgeneration AT ritaccol asemiautomaticmethodforpositioningafemoralbonereconstructionforstrictviewgeneration AT gomeza asemiautomaticmethodforpositioningafemoralbonereconstructionforstrictviewgeneration AT gonzalezbernaldodequirosf asemiautomaticmethodforpositioningafemoralbonereconstructionforstrictviewgeneration AT riskm asemiautomaticmethodforpositioningafemoralbonereconstructionforstrictviewgeneration AT milanof semiautomaticmethodforpositioningafemoralbonereconstructionforstrictviewgeneration AT ritaccol semiautomaticmethodforpositioningafemoralbonereconstructionforstrictviewgeneration AT gomeza semiautomaticmethodforpositioningafemoralbonereconstructionforstrictviewgeneration AT gonzalezbernaldodequirosf semiautomaticmethodforpositioningafemoralbonereconstructionforstrictviewgeneration AT riskm semiautomaticmethodforpositioningafemoralbonereconstructionforstrictviewgeneration |
_version_ |
1807319464254898176 |