Application of solid-state nuclear track detectors for studies of fast ion beams within PF-1000 and other plasma-focus facilities
The paper presents results of studies of the fast ion emission from two plasma facilities: PF-1000 and PF-II. The measurements were carried out mainly with solid-state nuclear track detectors (SSNTDs). To register ion mass- and energy-spectra, obtained when primary ion beams are deflected by magneti...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | JOUR |
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_13504487_v31_n1_p185_Sadowski |
Aporte de: |
id |
todo:paper_13504487_v31_n1_p185_Sadowski |
---|---|
record_format |
dspace |
spelling |
todo:paper_13504487_v31_n1_p185_Sadowski2023-10-03T16:09:56Z Application of solid-state nuclear track detectors for studies of fast ion beams within PF-1000 and other plasma-focus facilities Sadowski, M. Szydlowski, A. Scholz, M. Kelly, H. Marquez, A. Lepone, A. Electric fields Ion beams Ion sources Magnetic fields Particle beam tracking Plasmas Solid state devices Spectrometers Ion angular distribution Ion energy spectra Ion mass spectra Solid state nuclear track detectors Particle detectors The paper presents results of studies of the fast ion emission from two plasma facilities: PF-1000 and PF-II. The measurements were carried out mainly with solid-state nuclear track detectors (SSNTDs). To register ion mass- and energy-spectra, obtained when primary ion beams are deflected by magnetic and electric fields of a Thomson-type spectrometer, the SSNTDs plates were installed inside the analyzer. To measure ion angular distributions the SSNTDs were located within the main discharge chamber, at different angles to the electrode axis. The SSNTDs were also applied to register ion beam images formed within an ion pinhole camera, and to determine a spatial location of the fast ion sources. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_13504487_v31_n1_p185_Sadowski |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
Electric fields Ion beams Ion sources Magnetic fields Particle beam tracking Plasmas Solid state devices Spectrometers Ion angular distribution Ion energy spectra Ion mass spectra Solid state nuclear track detectors Particle detectors |
spellingShingle |
Electric fields Ion beams Ion sources Magnetic fields Particle beam tracking Plasmas Solid state devices Spectrometers Ion angular distribution Ion energy spectra Ion mass spectra Solid state nuclear track detectors Particle detectors Sadowski, M. Szydlowski, A. Scholz, M. Kelly, H. Marquez, A. Lepone, A. Application of solid-state nuclear track detectors for studies of fast ion beams within PF-1000 and other plasma-focus facilities |
topic_facet |
Electric fields Ion beams Ion sources Magnetic fields Particle beam tracking Plasmas Solid state devices Spectrometers Ion angular distribution Ion energy spectra Ion mass spectra Solid state nuclear track detectors Particle detectors |
description |
The paper presents results of studies of the fast ion emission from two plasma facilities: PF-1000 and PF-II. The measurements were carried out mainly with solid-state nuclear track detectors (SSNTDs). To register ion mass- and energy-spectra, obtained when primary ion beams are deflected by magnetic and electric fields of a Thomson-type spectrometer, the SSNTDs plates were installed inside the analyzer. To measure ion angular distributions the SSNTDs were located within the main discharge chamber, at different angles to the electrode axis. The SSNTDs were also applied to register ion beam images formed within an ion pinhole camera, and to determine a spatial location of the fast ion sources. |
format |
JOUR |
author |
Sadowski, M. Szydlowski, A. Scholz, M. Kelly, H. Marquez, A. Lepone, A. |
author_facet |
Sadowski, M. Szydlowski, A. Scholz, M. Kelly, H. Marquez, A. Lepone, A. |
author_sort |
Sadowski, M. |
title |
Application of solid-state nuclear track detectors for studies of fast ion beams within PF-1000 and other plasma-focus facilities |
title_short |
Application of solid-state nuclear track detectors for studies of fast ion beams within PF-1000 and other plasma-focus facilities |
title_full |
Application of solid-state nuclear track detectors for studies of fast ion beams within PF-1000 and other plasma-focus facilities |
title_fullStr |
Application of solid-state nuclear track detectors for studies of fast ion beams within PF-1000 and other plasma-focus facilities |
title_full_unstemmed |
Application of solid-state nuclear track detectors for studies of fast ion beams within PF-1000 and other plasma-focus facilities |
title_sort |
application of solid-state nuclear track detectors for studies of fast ion beams within pf-1000 and other plasma-focus facilities |
url |
http://hdl.handle.net/20.500.12110/paper_13504487_v31_n1_p185_Sadowski |
work_keys_str_mv |
AT sadowskim applicationofsolidstatenucleartrackdetectorsforstudiesoffastionbeamswithinpf1000andotherplasmafocusfacilities AT szydlowskia applicationofsolidstatenucleartrackdetectorsforstudiesoffastionbeamswithinpf1000andotherplasmafocusfacilities AT scholzm applicationofsolidstatenucleartrackdetectorsforstudiesoffastionbeamswithinpf1000andotherplasmafocusfacilities AT kellyh applicationofsolidstatenucleartrackdetectorsforstudiesoffastionbeamswithinpf1000andotherplasmafocusfacilities AT marqueza applicationofsolidstatenucleartrackdetectorsforstudiesoffastionbeamswithinpf1000andotherplasmafocusfacilities AT leponea applicationofsolidstatenucleartrackdetectorsforstudiesoffastionbeamswithinpf1000andotherplasmafocusfacilities |
_version_ |
1807320407339958272 |