Results from electrostatic calibrations for measuring the Casimir force in the cylinder-plane geometry
We report on measurements performed on an apparatus aimed to study the Casimir force in the cylinder-plane configuration. The electrostatic calibrations evidence anomalous behaviors in the dependence of the electrostatic force and the minimizing potential upon distance. We discuss analogies and diff...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | JOUR |
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_10502947_v81_n5_p_Wei |
Aporte de: |
id |
todo:paper_10502947_v81_n5_p_Wei |
---|---|
record_format |
dspace |
spelling |
todo:paper_10502947_v81_n5_p_Wei2023-10-03T16:00:05Z Results from electrostatic calibrations for measuring the Casimir force in the cylinder-plane geometry Wei, Q. Dalvit, D.A.R. Lombardo, F.C. Mazzitelli, F.D. Onofrio, R. Anomalous behavior Casimir force Cylinder-plane configuration Frequency shift Plane configurations Plane geometry Thermal correction Calibration Cylinders (shapes) Electric furnaces Electrostatic force Force measurement Geometry Optimization Spheres Quantum theory We report on measurements performed on an apparatus aimed to study the Casimir force in the cylinder-plane configuration. The electrostatic calibrations evidence anomalous behaviors in the dependence of the electrostatic force and the minimizing potential upon distance. We discuss analogies and differences of these anomalies with respect to those already observed in the sphere-plane configuration. At the smallest explored distances we observe frequency shifts of non-Coulombian nature preventing the measurement of the Casimir force in the same range. We also report on measurements performed in the parallel-plane configuration, showing that the dependence on distance of the minimizing potential, if present at all, is milder than in the sphere-plane or cylinder-plane geometries. General considerations on the interplay between the distance-dependent minimizing potential and the precision of Casimir force measurements in the range relevant to detect the thermal corrections for all geometries are finally reported. © 2010 The American Physical Society. Fil:Dalvit, D.A.R. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Lombardo, F.C. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Mazzitelli, F.D. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_10502947_v81_n5_p_Wei |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
Anomalous behavior Casimir force Cylinder-plane configuration Frequency shift Plane configurations Plane geometry Thermal correction Calibration Cylinders (shapes) Electric furnaces Electrostatic force Force measurement Geometry Optimization Spheres Quantum theory |
spellingShingle |
Anomalous behavior Casimir force Cylinder-plane configuration Frequency shift Plane configurations Plane geometry Thermal correction Calibration Cylinders (shapes) Electric furnaces Electrostatic force Force measurement Geometry Optimization Spheres Quantum theory Wei, Q. Dalvit, D.A.R. Lombardo, F.C. Mazzitelli, F.D. Onofrio, R. Results from electrostatic calibrations for measuring the Casimir force in the cylinder-plane geometry |
topic_facet |
Anomalous behavior Casimir force Cylinder-plane configuration Frequency shift Plane configurations Plane geometry Thermal correction Calibration Cylinders (shapes) Electric furnaces Electrostatic force Force measurement Geometry Optimization Spheres Quantum theory |
description |
We report on measurements performed on an apparatus aimed to study the Casimir force in the cylinder-plane configuration. The electrostatic calibrations evidence anomalous behaviors in the dependence of the electrostatic force and the minimizing potential upon distance. We discuss analogies and differences of these anomalies with respect to those already observed in the sphere-plane configuration. At the smallest explored distances we observe frequency shifts of non-Coulombian nature preventing the measurement of the Casimir force in the same range. We also report on measurements performed in the parallel-plane configuration, showing that the dependence on distance of the minimizing potential, if present at all, is milder than in the sphere-plane or cylinder-plane geometries. General considerations on the interplay between the distance-dependent minimizing potential and the precision of Casimir force measurements in the range relevant to detect the thermal corrections for all geometries are finally reported. © 2010 The American Physical Society. |
format |
JOUR |
author |
Wei, Q. Dalvit, D.A.R. Lombardo, F.C. Mazzitelli, F.D. Onofrio, R. |
author_facet |
Wei, Q. Dalvit, D.A.R. Lombardo, F.C. Mazzitelli, F.D. Onofrio, R. |
author_sort |
Wei, Q. |
title |
Results from electrostatic calibrations for measuring the Casimir force in the cylinder-plane geometry |
title_short |
Results from electrostatic calibrations for measuring the Casimir force in the cylinder-plane geometry |
title_full |
Results from electrostatic calibrations for measuring the Casimir force in the cylinder-plane geometry |
title_fullStr |
Results from electrostatic calibrations for measuring the Casimir force in the cylinder-plane geometry |
title_full_unstemmed |
Results from electrostatic calibrations for measuring the Casimir force in the cylinder-plane geometry |
title_sort |
results from electrostatic calibrations for measuring the casimir force in the cylinder-plane geometry |
url |
http://hdl.handle.net/20.500.12110/paper_10502947_v81_n5_p_Wei |
work_keys_str_mv |
AT weiq resultsfromelectrostaticcalibrationsformeasuringthecasimirforceinthecylinderplanegeometry AT dalvitdar resultsfromelectrostaticcalibrationsformeasuringthecasimirforceinthecylinderplanegeometry AT lombardofc resultsfromelectrostaticcalibrationsformeasuringthecasimirforceinthecylinderplanegeometry AT mazzitellifd resultsfromelectrostaticcalibrationsformeasuringthecasimirforceinthecylinderplanegeometry AT onofrior resultsfromelectrostaticcalibrationsformeasuringthecasimirforceinthecylinderplanegeometry |
_version_ |
1782029345826537472 |