Soft X-ray laser interferometer used for dense plasma diagnostics
Laser interferometry allows the recording of the electron density in a great variety of plasmas. However, the absorption and refraction imposes a limitation to the maximum density, plasma size and plasma gradient that can be measured with this technique. The development of compact soft X-ray laser s...
Autores principales: | , , , , , , |
---|---|
Formato: | JOUR |
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_0277786X_v4419_n_p106_Marconi |
Aporte de: |
id |
todo:paper_0277786X_v4419_n_p106_Marconi |
---|---|
record_format |
dspace |
spelling |
todo:paper_0277786X_v4419_n_p106_Marconi2023-10-03T15:16:16Z Soft X-ray laser interferometer used for dense plasma diagnostics Marconi, M. Filevich, J. Rocca, J.J. Jankowska, E. Hammerstein, E. Kanizay, K. Chilla, J.L.A. Laser interferometry X-ray laser Carrier concentration Interferometry Light absorption Light reflection Plasma diagnostics Laser interferometry X ray lasers Laser interferometry allows the recording of the electron density in a great variety of plasmas. However, the absorption and refraction imposes a limitation to the maximum density, plasma size and plasma gradient that can be measured with this technique. The development of compact soft X-ray laser sources gives the opportunity to extend the limits of plasma interferometry, probing plasmas with high densities and steep gradients. We present results of plasma interferometry using an amplitude division interferometer and a table top soft X-ray laser. The interferometer is a modified Mach-Zehnder configuration with diffraction gratings used as beam splitters. The soft X-ray laser is a 46.9 nm capillary discharge table-top laser. The set up was used to probe a laser-created plasma with a temporal resolution of ∼1 ns and densities up to 6 1020 cm-3. © 2001 SPIE · 0277-786X/01/$15.00. Fil:Marconi, M. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Chilla, J.L.A. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_0277786X_v4419_n_p106_Marconi |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
Laser interferometry X-ray laser Carrier concentration Interferometry Light absorption Light reflection Plasma diagnostics Laser interferometry X ray lasers |
spellingShingle |
Laser interferometry X-ray laser Carrier concentration Interferometry Light absorption Light reflection Plasma diagnostics Laser interferometry X ray lasers Marconi, M. Filevich, J. Rocca, J.J. Jankowska, E. Hammerstein, E. Kanizay, K. Chilla, J.L.A. Soft X-ray laser interferometer used for dense plasma diagnostics |
topic_facet |
Laser interferometry X-ray laser Carrier concentration Interferometry Light absorption Light reflection Plasma diagnostics Laser interferometry X ray lasers |
description |
Laser interferometry allows the recording of the electron density in a great variety of plasmas. However, the absorption and refraction imposes a limitation to the maximum density, plasma size and plasma gradient that can be measured with this technique. The development of compact soft X-ray laser sources gives the opportunity to extend the limits of plasma interferometry, probing plasmas with high densities and steep gradients. We present results of plasma interferometry using an amplitude division interferometer and a table top soft X-ray laser. The interferometer is a modified Mach-Zehnder configuration with diffraction gratings used as beam splitters. The soft X-ray laser is a 46.9 nm capillary discharge table-top laser. The set up was used to probe a laser-created plasma with a temporal resolution of ∼1 ns and densities up to 6 1020 cm-3. © 2001 SPIE · 0277-786X/01/$15.00. |
format |
JOUR |
author |
Marconi, M. Filevich, J. Rocca, J.J. Jankowska, E. Hammerstein, E. Kanizay, K. Chilla, J.L.A. |
author_facet |
Marconi, M. Filevich, J. Rocca, J.J. Jankowska, E. Hammerstein, E. Kanizay, K. Chilla, J.L.A. |
author_sort |
Marconi, M. |
title |
Soft X-ray laser interferometer used for dense plasma diagnostics |
title_short |
Soft X-ray laser interferometer used for dense plasma diagnostics |
title_full |
Soft X-ray laser interferometer used for dense plasma diagnostics |
title_fullStr |
Soft X-ray laser interferometer used for dense plasma diagnostics |
title_full_unstemmed |
Soft X-ray laser interferometer used for dense plasma diagnostics |
title_sort |
soft x-ray laser interferometer used for dense plasma diagnostics |
url |
http://hdl.handle.net/20.500.12110/paper_0277786X_v4419_n_p106_Marconi |
work_keys_str_mv |
AT marconim softxraylaserinterferometerusedfordenseplasmadiagnostics AT filevichj softxraylaserinterferometerusedfordenseplasmadiagnostics AT roccajj softxraylaserinterferometerusedfordenseplasmadiagnostics AT jankowskae softxraylaserinterferometerusedfordenseplasmadiagnostics AT hammersteine softxraylaserinterferometerusedfordenseplasmadiagnostics AT kanizayk softxraylaserinterferometerusedfordenseplasmadiagnostics AT chillajla softxraylaserinterferometerusedfordenseplasmadiagnostics |
_version_ |
1807323768732778496 |