The fluorescence detector of the Pierre Auger Observatory

The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Multitudinario:520
Formato: JOUR
Materias:
Acceso en línea:http://hdl.handle.net/20.500.12110/paper_01689002_v620_n2-3_p227_Multitudinario
Aporte de:
id todo:paper_01689002_v620_n2-3_p227_Multitudinario
record_format dspace
spelling todo:paper_01689002_v620_n2-3_p227_Multitudinario2023-10-03T15:06:44Z The fluorescence detector of the Pierre Auger Observatory Multitudinario:520 Cosmic rays Fluorescence detector Augers Charged particles Cosmic ray detectors Cosmic rays Cosmology Observatories Optical systems Absolute calibration Cosmic ray air showers Detector performance Fluorescence detector Hybrid detectors Pierre Auger observatory Secondary particles Ultra high-energy cosmic rays Fluorescence The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions. © 2010 Elsevier B.V. All rights reserved. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_01689002_v620_n2-3_p227_Multitudinario
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Cosmic rays
Fluorescence detector
Augers
Charged particles
Cosmic ray detectors
Cosmic rays
Cosmology
Observatories
Optical systems
Absolute calibration
Cosmic ray air showers
Detector performance
Fluorescence detector
Hybrid detectors
Pierre Auger observatory
Secondary particles
Ultra high-energy cosmic rays
Fluorescence
spellingShingle Cosmic rays
Fluorescence detector
Augers
Charged particles
Cosmic ray detectors
Cosmic rays
Cosmology
Observatories
Optical systems
Absolute calibration
Cosmic ray air showers
Detector performance
Fluorescence detector
Hybrid detectors
Pierre Auger observatory
Secondary particles
Ultra high-energy cosmic rays
Fluorescence
Multitudinario:520
The fluorescence detector of the Pierre Auger Observatory
topic_facet Cosmic rays
Fluorescence detector
Augers
Charged particles
Cosmic ray detectors
Cosmic rays
Cosmology
Observatories
Optical systems
Absolute calibration
Cosmic ray air showers
Detector performance
Fluorescence detector
Hybrid detectors
Pierre Auger observatory
Secondary particles
Ultra high-energy cosmic rays
Fluorescence
description The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions. © 2010 Elsevier B.V. All rights reserved.
format JOUR
author Multitudinario:520
author_facet Multitudinario:520
author_sort Multitudinario:520
title The fluorescence detector of the Pierre Auger Observatory
title_short The fluorescence detector of the Pierre Auger Observatory
title_full The fluorescence detector of the Pierre Auger Observatory
title_fullStr The fluorescence detector of the Pierre Auger Observatory
title_full_unstemmed The fluorescence detector of the Pierre Auger Observatory
title_sort fluorescence detector of the pierre auger observatory
url http://hdl.handle.net/20.500.12110/paper_01689002_v620_n2-3_p227_Multitudinario
work_keys_str_mv AT multitudinario520 thefluorescencedetectorofthepierreaugerobservatory
AT multitudinario520 fluorescencedetectorofthepierreaugerobservatory
_version_ 1782026115097821184