Integral system for detecting evaporation residues in fusion reactions

We have designed and constructed an integral system that involves two electrostatic deflectors followed by a small ionization chamber with a multi-wire-proportional-counter in its entrance. The function of the former part is to separate evaporation residues from beam ions using their different elect...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Capurro, O.A., Testoni, J.E., Marti, G.V., Arazi, A., Niello, J.O.F., Pacheco, A.J., Ortega, M.E., Tiffenberg, J., Fleitas, M.
Formato: JOUR
Acceso en línea:http://hdl.handle.net/20.500.12110/paper_01039733_v35_n3B_p731_Capurro
Aporte de:
id todo:paper_01039733_v35_n3B_p731_Capurro
record_format dspace
spelling todo:paper_01039733_v35_n3B_p731_Capurro2023-10-03T14:57:37Z Integral system for detecting evaporation residues in fusion reactions Capurro, O.A. Testoni, J.E. Marti, G.V. Arazi, A. Niello, J.O.F. Pacheco, A.J. Ortega, M.E. Tiffenberg, J. Fleitas, M. We have designed and constructed an integral system that involves two electrostatic deflectors followed by a small ionization chamber with a multi-wire-proportional-counter in its entrance. The function of the former part is to separate evaporation residues from beam ions using their different electric rigidities while the latter is to detect these evaporation residues being distinguished from the beam-like particles originated in slits. Up to now, both devices have been tested and evaluated performing different experiments: the double-electrostatic deflector through scattering studies and the ionization chamber by means of scattering and fusion reactions. We present a brief description of the two devices and some results obtained in different tests. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_01039733_v35_n3B_p731_Capurro
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
description We have designed and constructed an integral system that involves two electrostatic deflectors followed by a small ionization chamber with a multi-wire-proportional-counter in its entrance. The function of the former part is to separate evaporation residues from beam ions using their different electric rigidities while the latter is to detect these evaporation residues being distinguished from the beam-like particles originated in slits. Up to now, both devices have been tested and evaluated performing different experiments: the double-electrostatic deflector through scattering studies and the ionization chamber by means of scattering and fusion reactions. We present a brief description of the two devices and some results obtained in different tests.
format JOUR
author Capurro, O.A.
Testoni, J.E.
Marti, G.V.
Arazi, A.
Niello, J.O.F.
Pacheco, A.J.
Ortega, M.E.
Tiffenberg, J.
Fleitas, M.
spellingShingle Capurro, O.A.
Testoni, J.E.
Marti, G.V.
Arazi, A.
Niello, J.O.F.
Pacheco, A.J.
Ortega, M.E.
Tiffenberg, J.
Fleitas, M.
Integral system for detecting evaporation residues in fusion reactions
author_facet Capurro, O.A.
Testoni, J.E.
Marti, G.V.
Arazi, A.
Niello, J.O.F.
Pacheco, A.J.
Ortega, M.E.
Tiffenberg, J.
Fleitas, M.
author_sort Capurro, O.A.
title Integral system for detecting evaporation residues in fusion reactions
title_short Integral system for detecting evaporation residues in fusion reactions
title_full Integral system for detecting evaporation residues in fusion reactions
title_fullStr Integral system for detecting evaporation residues in fusion reactions
title_full_unstemmed Integral system for detecting evaporation residues in fusion reactions
title_sort integral system for detecting evaporation residues in fusion reactions
url http://hdl.handle.net/20.500.12110/paper_01039733_v35_n3B_p731_Capurro
work_keys_str_mv AT capurrooa integralsystemfordetectingevaporationresiduesinfusionreactions
AT testonije integralsystemfordetectingevaporationresiduesinfusionreactions
AT martigv integralsystemfordetectingevaporationresiduesinfusionreactions
AT arazia integralsystemfordetectingevaporationresiduesinfusionreactions
AT niellojof integralsystemfordetectingevaporationresiduesinfusionreactions
AT pachecoaj integralsystemfordetectingevaporationresiduesinfusionreactions
AT ortegame integralsystemfordetectingevaporationresiduesinfusionreactions
AT tiffenbergj integralsystemfordetectingevaporationresiduesinfusionreactions
AT fleitasm integralsystemfordetectingevaporationresiduesinfusionreactions
_version_ 1807314891391893504