pH front tracking in the electrochemical treatment (EChT) of tumors: Experiments and simulations
The extreme cathodic and anodic pH fronts induced in the electrochemical treatment of tumors (EChT) are the main cause of tumor necrosis. Here, we study pH fronts interaction in a tissue under EChT through in vitro and in silico modeling. The in vitro model considers the tumor tissue as a buffered g...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | JOUR |
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_00134686_v54_n26_p6199_Turjanski |
Aporte de: |
id |
todo:paper_00134686_v54_n26_p6199_Turjanski |
---|---|
record_format |
dspace |
spelling |
todo:paper_00134686_v54_n26_p6199_Turjanski2023-10-03T14:11:02Z pH front tracking in the electrochemical treatment (EChT) of tumors: Experiments and simulations Turjanski, P. Olaiz, N. Abou-Adal, P. Suárez, C. Risk, M. Marshall, G. Electroacupuncture Electrochemical treatment Mathematical modeling Numerical simulation Tumor Electrochemical treatment Electrochemical treatments Experimental measurements Front tracking In-silico In-silico models In-vitro Ion transports Mathematical modeling Nernst-Planck equations Neutral pH Numerical simulation Strong correlation Tumor necrosis Tumor tissues Computer simulation languages Electroacupuncture Gelation Oncology Sodium chloride Tumors Simulators The extreme cathodic and anodic pH fronts induced in the electrochemical treatment of tumors (EChT) are the main cause of tumor necrosis. Here, we study pH fronts interaction in a tissue under EChT through in vitro and in silico modeling. The in vitro model considers the tumor tissue as a buffered gel with saline (NaCl) content and the cathodic treated area as the area of phenolphtalein virage. The in silico model solves the 1D Nernst-Planck equations for ion transport in a four-ion electrolyte. In silico modeling predicts an initial neutral pH profile evolving into extreme cathodic alkaline and anodic acidic fronts moving towards each other and colliding, thus excluding the existence of a biological pH region between them. Moreover, the model predicts that as electric current increases, pH front scaling grows as t1, unveiling a transition from a diffusion to a migration governed regime. Theory and simulations have a strong correlation with experimental measurements. Since necrotic areas correlate well with those covered by alkaline and acid fronts advance, pH front tracking can be used to predict the extent of tumor destruction and thus, the assessment of EChT effectiveness. © 2009 Elsevier Ltd. All rights reserved. Fil:Turjanski, P. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Suárez, C. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_00134686_v54_n26_p6199_Turjanski |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
Electroacupuncture Electrochemical treatment Mathematical modeling Numerical simulation Tumor Electrochemical treatment Electrochemical treatments Experimental measurements Front tracking In-silico In-silico models In-vitro Ion transports Mathematical modeling Nernst-Planck equations Neutral pH Numerical simulation Strong correlation Tumor necrosis Tumor tissues Computer simulation languages Electroacupuncture Gelation Oncology Sodium chloride Tumors Simulators |
spellingShingle |
Electroacupuncture Electrochemical treatment Mathematical modeling Numerical simulation Tumor Electrochemical treatment Electrochemical treatments Experimental measurements Front tracking In-silico In-silico models In-vitro Ion transports Mathematical modeling Nernst-Planck equations Neutral pH Numerical simulation Strong correlation Tumor necrosis Tumor tissues Computer simulation languages Electroacupuncture Gelation Oncology Sodium chloride Tumors Simulators Turjanski, P. Olaiz, N. Abou-Adal, P. Suárez, C. Risk, M. Marshall, G. pH front tracking in the electrochemical treatment (EChT) of tumors: Experiments and simulations |
topic_facet |
Electroacupuncture Electrochemical treatment Mathematical modeling Numerical simulation Tumor Electrochemical treatment Electrochemical treatments Experimental measurements Front tracking In-silico In-silico models In-vitro Ion transports Mathematical modeling Nernst-Planck equations Neutral pH Numerical simulation Strong correlation Tumor necrosis Tumor tissues Computer simulation languages Electroacupuncture Gelation Oncology Sodium chloride Tumors Simulators |
description |
The extreme cathodic and anodic pH fronts induced in the electrochemical treatment of tumors (EChT) are the main cause of tumor necrosis. Here, we study pH fronts interaction in a tissue under EChT through in vitro and in silico modeling. The in vitro model considers the tumor tissue as a buffered gel with saline (NaCl) content and the cathodic treated area as the area of phenolphtalein virage. The in silico model solves the 1D Nernst-Planck equations for ion transport in a four-ion electrolyte. In silico modeling predicts an initial neutral pH profile evolving into extreme cathodic alkaline and anodic acidic fronts moving towards each other and colliding, thus excluding the existence of a biological pH region between them. Moreover, the model predicts that as electric current increases, pH front scaling grows as t1, unveiling a transition from a diffusion to a migration governed regime. Theory and simulations have a strong correlation with experimental measurements. Since necrotic areas correlate well with those covered by alkaline and acid fronts advance, pH front tracking can be used to predict the extent of tumor destruction and thus, the assessment of EChT effectiveness. © 2009 Elsevier Ltd. All rights reserved. |
format |
JOUR |
author |
Turjanski, P. Olaiz, N. Abou-Adal, P. Suárez, C. Risk, M. Marshall, G. |
author_facet |
Turjanski, P. Olaiz, N. Abou-Adal, P. Suárez, C. Risk, M. Marshall, G. |
author_sort |
Turjanski, P. |
title |
pH front tracking in the electrochemical treatment (EChT) of tumors: Experiments and simulations |
title_short |
pH front tracking in the electrochemical treatment (EChT) of tumors: Experiments and simulations |
title_full |
pH front tracking in the electrochemical treatment (EChT) of tumors: Experiments and simulations |
title_fullStr |
pH front tracking in the electrochemical treatment (EChT) of tumors: Experiments and simulations |
title_full_unstemmed |
pH front tracking in the electrochemical treatment (EChT) of tumors: Experiments and simulations |
title_sort |
ph front tracking in the electrochemical treatment (echt) of tumors: experiments and simulations |
url |
http://hdl.handle.net/20.500.12110/paper_00134686_v54_n26_p6199_Turjanski |
work_keys_str_mv |
AT turjanskip phfronttrackingintheelectrochemicaltreatmentechtoftumorsexperimentsandsimulations AT olaizn phfronttrackingintheelectrochemicaltreatmentechtoftumorsexperimentsandsimulations AT abouadalp phfronttrackingintheelectrochemicaltreatmentechtoftumorsexperimentsandsimulations AT suarezc phfronttrackingintheelectrochemicaltreatmentechtoftumorsexperimentsandsimulations AT riskm phfronttrackingintheelectrochemicaltreatmentechtoftumorsexperimentsandsimulations AT marshallg phfronttrackingintheelectrochemicaltreatmentechtoftumorsexperimentsandsimulations |
_version_ |
1807316403681755136 |