Optimal dose-response relationship in electrolytic ablation of tumors with a one-probe-two-electrode device

Electrolytic ablation (EA), a medical treatment used in solid tumor ablation due to its minimum side effects and low cost, consists in the passage of a low constant electric current through two or more electrodes inserted in the tissue thus inducing pH fronts that produce tumor necrosis. Combined wi...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Luján, E., Schinca, H., Olaiz, N., Urquiza, S., Molina, F.V., Turjanski, P., Marshall, G.
Formato: JOUR
Materias:
Acceso en línea:http://hdl.handle.net/20.500.12110/paper_00134686_v186_n_p494_Lujan
Aporte de:
id todo:paper_00134686_v186_n_p494_Lujan
record_format dspace
spelling todo:paper_00134686_v186_n_p494_Lujan2023-10-03T14:10:52Z Optimal dose-response relationship in electrolytic ablation of tumors with a one-probe-two-electrode device Luján, E. Schinca, H. Olaiz, N. Urquiza, S. Molina, F.V. Turjanski, P. Marshall, G. Electrochemical treatment Electrolytic ablation in silico models in vitro models pH front tracking Tumors Ablation Electrodes Probes Tissue Dose response relationships Electrochemical reactions Electrochemical treatments Front tracking In-silico models In-vitro models Minimally invasive treatments Non-linear relationships Tumors Electrolytic ablation (EA), a medical treatment used in solid tumor ablation due to its minimum side effects and low cost, consists in the passage of a low constant electric current through two or more electrodes inserted in the tissue thus inducing pH fronts that produce tumor necrosis. Combined with a recently introduced one-probe two electrode device (OPTED) this procedure results in a minimally invasive treatment. Despite its success, EA has drawbacks such as the difficulties in determining the optimum dose-response relationship between the applied current, treatment time and necrotized tumor volume (NTV) and choosing a reliable dose parameter. In this work, a theoretical model is introduced describing the EA/OPTED as an electrolytic process and the underlying electrochemical reactions through the Nernst-Planck equations for ion transport. Model results show that the coulomb dosage is a reliable dose parameter and predicts an optimal dose-response relationship for a given tumor size subjected to an EA/OPTED, considering the optimum as the minimum coulomb dosage necessary to achieve total tumor destruction while minimizing healthy tissue damage. Moreover, it predicts a nonlinear relationship between coulomb dosage and NTV, dosage and NTV scaling as Q1.4. Consequently, these results could have a significant impact on dose planning methodology aimed at improving the effectiveness of the electrolytic ablation. © 2015 Elsevier Ltd. Fil:Molina, F.V. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Turjanski, P. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_00134686_v186_n_p494_Lujan
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Electrochemical treatment
Electrolytic ablation
in silico models
in vitro models
pH front tracking
Tumors
Ablation
Electrodes
Probes
Tissue
Dose response relationships
Electrochemical reactions
Electrochemical treatments
Front tracking
In-silico models
In-vitro models
Minimally invasive treatments
Non-linear relationships
Tumors
spellingShingle Electrochemical treatment
Electrolytic ablation
in silico models
in vitro models
pH front tracking
Tumors
Ablation
Electrodes
Probes
Tissue
Dose response relationships
Electrochemical reactions
Electrochemical treatments
Front tracking
In-silico models
In-vitro models
Minimally invasive treatments
Non-linear relationships
Tumors
Luján, E.
Schinca, H.
Olaiz, N.
Urquiza, S.
Molina, F.V.
Turjanski, P.
Marshall, G.
Optimal dose-response relationship in electrolytic ablation of tumors with a one-probe-two-electrode device
topic_facet Electrochemical treatment
Electrolytic ablation
in silico models
in vitro models
pH front tracking
Tumors
Ablation
Electrodes
Probes
Tissue
Dose response relationships
Electrochemical reactions
Electrochemical treatments
Front tracking
In-silico models
In-vitro models
Minimally invasive treatments
Non-linear relationships
Tumors
description Electrolytic ablation (EA), a medical treatment used in solid tumor ablation due to its minimum side effects and low cost, consists in the passage of a low constant electric current through two or more electrodes inserted in the tissue thus inducing pH fronts that produce tumor necrosis. Combined with a recently introduced one-probe two electrode device (OPTED) this procedure results in a minimally invasive treatment. Despite its success, EA has drawbacks such as the difficulties in determining the optimum dose-response relationship between the applied current, treatment time and necrotized tumor volume (NTV) and choosing a reliable dose parameter. In this work, a theoretical model is introduced describing the EA/OPTED as an electrolytic process and the underlying electrochemical reactions through the Nernst-Planck equations for ion transport. Model results show that the coulomb dosage is a reliable dose parameter and predicts an optimal dose-response relationship for a given tumor size subjected to an EA/OPTED, considering the optimum as the minimum coulomb dosage necessary to achieve total tumor destruction while minimizing healthy tissue damage. Moreover, it predicts a nonlinear relationship between coulomb dosage and NTV, dosage and NTV scaling as Q1.4. Consequently, these results could have a significant impact on dose planning methodology aimed at improving the effectiveness of the electrolytic ablation. © 2015 Elsevier Ltd.
format JOUR
author Luján, E.
Schinca, H.
Olaiz, N.
Urquiza, S.
Molina, F.V.
Turjanski, P.
Marshall, G.
author_facet Luján, E.
Schinca, H.
Olaiz, N.
Urquiza, S.
Molina, F.V.
Turjanski, P.
Marshall, G.
author_sort Luján, E.
title Optimal dose-response relationship in electrolytic ablation of tumors with a one-probe-two-electrode device
title_short Optimal dose-response relationship in electrolytic ablation of tumors with a one-probe-two-electrode device
title_full Optimal dose-response relationship in electrolytic ablation of tumors with a one-probe-two-electrode device
title_fullStr Optimal dose-response relationship in electrolytic ablation of tumors with a one-probe-two-electrode device
title_full_unstemmed Optimal dose-response relationship in electrolytic ablation of tumors with a one-probe-two-electrode device
title_sort optimal dose-response relationship in electrolytic ablation of tumors with a one-probe-two-electrode device
url http://hdl.handle.net/20.500.12110/paper_00134686_v186_n_p494_Lujan
work_keys_str_mv AT lujane optimaldoseresponserelationshipinelectrolyticablationoftumorswithaoneprobetwoelectrodedevice
AT schincah optimaldoseresponserelationshipinelectrolyticablationoftumorswithaoneprobetwoelectrodedevice
AT olaizn optimaldoseresponserelationshipinelectrolyticablationoftumorswithaoneprobetwoelectrodedevice
AT urquizas optimaldoseresponserelationshipinelectrolyticablationoftumorswithaoneprobetwoelectrodedevice
AT molinafv optimaldoseresponserelationshipinelectrolyticablationoftumorswithaoneprobetwoelectrodedevice
AT turjanskip optimaldoseresponserelationshipinelectrolyticablationoftumorswithaoneprobetwoelectrodedevice
AT marshallg optimaldoseresponserelationshipinelectrolyticablationoftumorswithaoneprobetwoelectrodedevice
_version_ 1782026389638086656