Fast cycle, wide temperature range a.c. susceptometer
An a.c. susceptometer of simple design, operating from 4 K to room temperature is described. The sample can be easily replaced and cooled to 4 K in less than 1 h with low helium boil-off. Measuring coils are immersed in the cryogenic bath, so that a serious source of thermal drift voltage is avoided...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | JOUR |
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_00112275_v33_n11_p1037_Ferrari |
Aporte de: |
id |
todo:paper_00112275_v33_n11_p1037_Ferrari |
---|---|
record_format |
dspace |
spelling |
todo:paper_00112275_v33_n11_p1037_Ferrari2023-10-03T14:09:43Z Fast cycle, wide temperature range a.c. susceptometer Ferrari, H. Codner, G. Melgarejo, D.R. Levy, P. Acha, C. Bekeris, V. a.c. susceptibility cryostats design considerations Cooling Cryostats Dewars Electric coils Electric conductivity Helium Magnetic fields Magnetic variables measurement Superconducting magnets Alternating current susceptibility Alternating current susceptometer Cryogenic bath Helium boil off Measuring coils Mutual inductance Thermal drift voltage Magnetic measuring instruments An a.c. susceptometer of simple design, operating from 4 K to room temperature is described. The sample can be easily replaced and cooled to 4 K in less than 1 h with low helium boil-off. Measuring coils are immersed in the cryogenic bath, so that a serious source of thermal drift voltage is avoided. © 1993. Fil:Ferrari, H. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Codner, G. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Levy, P. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Acha, C. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Bekeris, V. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_00112275_v33_n11_p1037_Ferrari |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
a.c. susceptibility cryostats design considerations Cooling Cryostats Dewars Electric coils Electric conductivity Helium Magnetic fields Magnetic variables measurement Superconducting magnets Alternating current susceptibility Alternating current susceptometer Cryogenic bath Helium boil off Measuring coils Mutual inductance Thermal drift voltage Magnetic measuring instruments |
spellingShingle |
a.c. susceptibility cryostats design considerations Cooling Cryostats Dewars Electric coils Electric conductivity Helium Magnetic fields Magnetic variables measurement Superconducting magnets Alternating current susceptibility Alternating current susceptometer Cryogenic bath Helium boil off Measuring coils Mutual inductance Thermal drift voltage Magnetic measuring instruments Ferrari, H. Codner, G. Melgarejo, D.R. Levy, P. Acha, C. Bekeris, V. Fast cycle, wide temperature range a.c. susceptometer |
topic_facet |
a.c. susceptibility cryostats design considerations Cooling Cryostats Dewars Electric coils Electric conductivity Helium Magnetic fields Magnetic variables measurement Superconducting magnets Alternating current susceptibility Alternating current susceptometer Cryogenic bath Helium boil off Measuring coils Mutual inductance Thermal drift voltage Magnetic measuring instruments |
description |
An a.c. susceptometer of simple design, operating from 4 K to room temperature is described. The sample can be easily replaced and cooled to 4 K in less than 1 h with low helium boil-off. Measuring coils are immersed in the cryogenic bath, so that a serious source of thermal drift voltage is avoided. © 1993. |
format |
JOUR |
author |
Ferrari, H. Codner, G. Melgarejo, D.R. Levy, P. Acha, C. Bekeris, V. |
author_facet |
Ferrari, H. Codner, G. Melgarejo, D.R. Levy, P. Acha, C. Bekeris, V. |
author_sort |
Ferrari, H. |
title |
Fast cycle, wide temperature range a.c. susceptometer |
title_short |
Fast cycle, wide temperature range a.c. susceptometer |
title_full |
Fast cycle, wide temperature range a.c. susceptometer |
title_fullStr |
Fast cycle, wide temperature range a.c. susceptometer |
title_full_unstemmed |
Fast cycle, wide temperature range a.c. susceptometer |
title_sort |
fast cycle, wide temperature range a.c. susceptometer |
url |
http://hdl.handle.net/20.500.12110/paper_00112275_v33_n11_p1037_Ferrari |
work_keys_str_mv |
AT ferrarih fastcyclewidetemperaturerangeacsusceptometer AT codnerg fastcyclewidetemperaturerangeacsusceptometer AT melgarejodr fastcyclewidetemperaturerangeacsusceptometer AT levyp fastcyclewidetemperaturerangeacsusceptometer AT achac fastcyclewidetemperaturerangeacsusceptometer AT bekerisv fastcyclewidetemperaturerangeacsusceptometer |
_version_ |
1807318031559294976 |