Comparison of two-dimensional models for fixed bed catalytic reactors
The performance of different two-dimensional models of fixed bed catalytic reactors is analyzed for different situations. The deviation of the response of the simplified models with respect to the heterogeneous one is explained in terms of the operative conditions and the value of dimensionless grou...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | JOUR |
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_00092509_v39_n6_p1017_PereiraDuarte |
Aporte de: |
id |
todo:paper_00092509_v39_n6_p1017_PereiraDuarte |
---|---|
record_format |
dspace |
spelling |
todo:paper_00092509_v39_n6_p1017_PereiraDuarte2023-10-03T14:08:03Z Comparison of two-dimensional models for fixed bed catalytic reactors Pereira Duarte, S.I. Barreto, G.F. Lemcoff, N.O. HEAT TRANSFER CHEMICAL EQUIPMENT The performance of different two-dimensional models of fixed bed catalytic reactors is analyzed for different situations. The deviation of the response of the simplified models with respect to the heterogeneous one is explained in terms of the operative conditions and the value of dimensionless groups. A very simple expression to predict the error in the conversion for the models considered is derived. A reasonable agreement with the errors calculated from the numerical solution of the two-dimensional models is found. © 1947. Fil:Lemcoff, N.O. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_00092509_v39_n6_p1017_PereiraDuarte |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
HEAT TRANSFER CHEMICAL EQUIPMENT |
spellingShingle |
HEAT TRANSFER CHEMICAL EQUIPMENT Pereira Duarte, S.I. Barreto, G.F. Lemcoff, N.O. Comparison of two-dimensional models for fixed bed catalytic reactors |
topic_facet |
HEAT TRANSFER CHEMICAL EQUIPMENT |
description |
The performance of different two-dimensional models of fixed bed catalytic reactors is analyzed for different situations. The deviation of the response of the simplified models with respect to the heterogeneous one is explained in terms of the operative conditions and the value of dimensionless groups. A very simple expression to predict the error in the conversion for the models considered is derived. A reasonable agreement with the errors calculated from the numerical solution of the two-dimensional models is found. © 1947. |
format |
JOUR |
author |
Pereira Duarte, S.I. Barreto, G.F. Lemcoff, N.O. |
author_facet |
Pereira Duarte, S.I. Barreto, G.F. Lemcoff, N.O. |
author_sort |
Pereira Duarte, S.I. |
title |
Comparison of two-dimensional models for fixed bed catalytic reactors |
title_short |
Comparison of two-dimensional models for fixed bed catalytic reactors |
title_full |
Comparison of two-dimensional models for fixed bed catalytic reactors |
title_fullStr |
Comparison of two-dimensional models for fixed bed catalytic reactors |
title_full_unstemmed |
Comparison of two-dimensional models for fixed bed catalytic reactors |
title_sort |
comparison of two-dimensional models for fixed bed catalytic reactors |
url |
http://hdl.handle.net/20.500.12110/paper_00092509_v39_n6_p1017_PereiraDuarte |
work_keys_str_mv |
AT pereiraduartesi comparisonoftwodimensionalmodelsforfixedbedcatalyticreactors AT barretogf comparisonoftwodimensionalmodelsforfixedbedcatalyticreactors AT lemcoffno comparisonoftwodimensionalmodelsforfixedbedcatalyticreactors |
_version_ |
1782026248345616384 |