Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography
A previous paper (Frazin et al. 2005b) introduced the concept of differential emission measure tomography (DEMT), which is a three-dimensional (3D) extension of the classical differential emission measure technique for determining the distribution of temperatures in a volume of plasma. The informati...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | JOUR |
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_0004637X_v701_n1_p547_Frazin |
Aporte de: |
id |
todo:paper_0004637X_v701_n1_p547_Frazin |
---|---|
record_format |
dspace |
spelling |
todo:paper_0004637X_v701_n1_p547_Frazin2023-10-03T14:02:10Z Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography Frazin, R.A. Vsquez, A.M. Kamalabadi, F. Sun: corona Sun: prominences Sun: UV radiation A previous paper (Frazin et al. 2005b) introduced the concept of differential emission measure tomography (DEMT), which is a three-dimensional (3D) extension of the classical differential emission measure technique for determining the distribution of temperatures in a volume of plasma. The information for the reconstruction in the three spatial dimensions is provided by solar rotation and/or multi-spacecraft views. This paper describes, quantitatively, the procedure for implementing DEMT with data from NASA's STEREO/EUVI instrument, including the radiometry, line-of-sight geometry, and image preparation steps. An example of a quantitative, multiband, 3D reconstruction and local differential emission measure curves are given, and it is demonstrated that, when applicable, DEMT is a simple 3D analysis tool that obviates the need for structure-specific modeling. © 2009 The American Astronomical Society. All rights reserved. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_0004637X_v701_n1_p547_Frazin |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
Sun: corona Sun: prominences Sun: UV radiation |
spellingShingle |
Sun: corona Sun: prominences Sun: UV radiation Frazin, R.A. Vsquez, A.M. Kamalabadi, F. Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography |
topic_facet |
Sun: corona Sun: prominences Sun: UV radiation |
description |
A previous paper (Frazin et al. 2005b) introduced the concept of differential emission measure tomography (DEMT), which is a three-dimensional (3D) extension of the classical differential emission measure technique for determining the distribution of temperatures in a volume of plasma. The information for the reconstruction in the three spatial dimensions is provided by solar rotation and/or multi-spacecraft views. This paper describes, quantitatively, the procedure for implementing DEMT with data from NASA's STEREO/EUVI instrument, including the radiometry, line-of-sight geometry, and image preparation steps. An example of a quantitative, multiband, 3D reconstruction and local differential emission measure curves are given, and it is demonstrated that, when applicable, DEMT is a simple 3D analysis tool that obviates the need for structure-specific modeling. © 2009 The American Astronomical Society. All rights reserved. |
format |
JOUR |
author |
Frazin, R.A. Vsquez, A.M. Kamalabadi, F. |
author_facet |
Frazin, R.A. Vsquez, A.M. Kamalabadi, F. |
author_sort |
Frazin, R.A. |
title |
Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography |
title_short |
Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography |
title_full |
Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography |
title_fullStr |
Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography |
title_full_unstemmed |
Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography |
title_sort |
quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography |
url |
http://hdl.handle.net/20.500.12110/paper_0004637X_v701_n1_p547_Frazin |
work_keys_str_mv |
AT frazinra quantitativethreedimensionalanalysisoftheglobalcoronawithmultispacecraftdifferentialemissionmeasuretomography AT vsquezam quantitativethreedimensionalanalysisoftheglobalcoronawithmultispacecraftdifferentialemissionmeasuretomography AT kamalabadif quantitativethreedimensionalanalysisoftheglobalcoronawithmultispacecraftdifferentialemissionmeasuretomography |
_version_ |
1807318583979540480 |