Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography

A previous paper (Frazin et al. 2005b) introduced the concept of differential emission measure tomography (DEMT), which is a three-dimensional (3D) extension of the classical differential emission measure technique for determining the distribution of temperatures in a volume of plasma. The informati...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Frazin, R.A., Vsquez, A.M., Kamalabadi, F.
Formato: JOUR
Materias:
Acceso en línea:http://hdl.handle.net/20.500.12110/paper_0004637X_v701_n1_p547_Frazin
Aporte de:
id todo:paper_0004637X_v701_n1_p547_Frazin
record_format dspace
spelling todo:paper_0004637X_v701_n1_p547_Frazin2023-10-03T14:02:10Z Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography Frazin, R.A. Vsquez, A.M. Kamalabadi, F. Sun: corona Sun: prominences Sun: UV radiation A previous paper (Frazin et al. 2005b) introduced the concept of differential emission measure tomography (DEMT), which is a three-dimensional (3D) extension of the classical differential emission measure technique for determining the distribution of temperatures in a volume of plasma. The information for the reconstruction in the three spatial dimensions is provided by solar rotation and/or multi-spacecraft views. This paper describes, quantitatively, the procedure for implementing DEMT with data from NASA's STEREO/EUVI instrument, including the radiometry, line-of-sight geometry, and image preparation steps. An example of a quantitative, multiband, 3D reconstruction and local differential emission measure curves are given, and it is demonstrated that, when applicable, DEMT is a simple 3D analysis tool that obviates the need for structure-specific modeling. © 2009 The American Astronomical Society. All rights reserved. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_0004637X_v701_n1_p547_Frazin
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Sun: corona
Sun: prominences
Sun: UV radiation
spellingShingle Sun: corona
Sun: prominences
Sun: UV radiation
Frazin, R.A.
Vsquez, A.M.
Kamalabadi, F.
Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography
topic_facet Sun: corona
Sun: prominences
Sun: UV radiation
description A previous paper (Frazin et al. 2005b) introduced the concept of differential emission measure tomography (DEMT), which is a three-dimensional (3D) extension of the classical differential emission measure technique for determining the distribution of temperatures in a volume of plasma. The information for the reconstruction in the three spatial dimensions is provided by solar rotation and/or multi-spacecraft views. This paper describes, quantitatively, the procedure for implementing DEMT with data from NASA's STEREO/EUVI instrument, including the radiometry, line-of-sight geometry, and image preparation steps. An example of a quantitative, multiband, 3D reconstruction and local differential emission measure curves are given, and it is demonstrated that, when applicable, DEMT is a simple 3D analysis tool that obviates the need for structure-specific modeling. © 2009 The American Astronomical Society. All rights reserved.
format JOUR
author Frazin, R.A.
Vsquez, A.M.
Kamalabadi, F.
author_facet Frazin, R.A.
Vsquez, A.M.
Kamalabadi, F.
author_sort Frazin, R.A.
title Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography
title_short Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography
title_full Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography
title_fullStr Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography
title_full_unstemmed Quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography
title_sort quantitative, three-dimensional analysis of the global corona with multi-spacecraft differential emission measure tomography
url http://hdl.handle.net/20.500.12110/paper_0004637X_v701_n1_p547_Frazin
work_keys_str_mv AT frazinra quantitativethreedimensionalanalysisoftheglobalcoronawithmultispacecraftdifferentialemissionmeasuretomography
AT vsquezam quantitativethreedimensionalanalysisoftheglobalcoronawithmultispacecraftdifferentialemissionmeasuretomography
AT kamalabadif quantitativethreedimensionalanalysisoftheglobalcoronawithmultispacecraftdifferentialemissionmeasuretomography
_version_ 1807318583979540480