1D and 2D temperature imaging with a fluorescent ruthenium complex

Temperature imaging based on the fluorescence of the complex [Ru(bpy) 3]2+ is described. The method allows precise temperature measurement on unidimensional flow injection reactors and bidimensional measurement on dishes for biological and biochemical assays. The fluorescence dependence on temperatu...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Filevich, O., Etchenique, R.
Formato: JOUR
Materias:
Acceso en línea:http://hdl.handle.net/20.500.12110/paper_00032700_v78_n21_p7499_Filevich
Aporte de:
id todo:paper_00032700_v78_n21_p7499_Filevich
record_format dspace
spelling todo:paper_00032700_v78_n21_p7499_Filevich2023-10-03T13:56:01Z 1D and 2D temperature imaging with a fluorescent ruthenium complex Filevich, O. Etchenique, R. Bioassay Cameras Chemical reactors Fluorescence Imaging techniques Temperature measurement Flow injection reactors Fluorescence microscopes Two-point calibration Ruthenium compounds ruthenium complex article bioassay calibration camera filter flow injection analysis fluorescence fluorescence microscope imaging linear system optical resolution optics temperature imaging temperature measurement Temperature imaging based on the fluorescence of the complex [Ru(bpy) 3]2+ is described. The method allows precise temperature measurement on unidimensional flow injection reactors and bidimensional measurement on dishes for biological and biochemical assays. The fluorescence dependence on temperature is linear, achieving a resolution of 0.05 K with a simple two-point calibration. The large Stokes shift of [Ru(bpy) 3]2+ makes it easy to use a simple CCD camera without special filters. Large or small area fields can be achieved by changing the optics of the camera. High spatial resolution is possible by using any fluorescence microscope. © 2006 American Chemical Society. Fil:Filevich, O. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Etchenique, R. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_00032700_v78_n21_p7499_Filevich
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Bioassay
Cameras
Chemical reactors
Fluorescence
Imaging techniques
Temperature measurement
Flow injection reactors
Fluorescence microscopes
Two-point calibration
Ruthenium compounds
ruthenium complex
article
bioassay
calibration
camera
filter
flow injection analysis
fluorescence
fluorescence microscope
imaging
linear system
optical resolution
optics
temperature imaging
temperature measurement
spellingShingle Bioassay
Cameras
Chemical reactors
Fluorescence
Imaging techniques
Temperature measurement
Flow injection reactors
Fluorescence microscopes
Two-point calibration
Ruthenium compounds
ruthenium complex
article
bioassay
calibration
camera
filter
flow injection analysis
fluorescence
fluorescence microscope
imaging
linear system
optical resolution
optics
temperature imaging
temperature measurement
Filevich, O.
Etchenique, R.
1D and 2D temperature imaging with a fluorescent ruthenium complex
topic_facet Bioassay
Cameras
Chemical reactors
Fluorescence
Imaging techniques
Temperature measurement
Flow injection reactors
Fluorescence microscopes
Two-point calibration
Ruthenium compounds
ruthenium complex
article
bioassay
calibration
camera
filter
flow injection analysis
fluorescence
fluorescence microscope
imaging
linear system
optical resolution
optics
temperature imaging
temperature measurement
description Temperature imaging based on the fluorescence of the complex [Ru(bpy) 3]2+ is described. The method allows precise temperature measurement on unidimensional flow injection reactors and bidimensional measurement on dishes for biological and biochemical assays. The fluorescence dependence on temperature is linear, achieving a resolution of 0.05 K with a simple two-point calibration. The large Stokes shift of [Ru(bpy) 3]2+ makes it easy to use a simple CCD camera without special filters. Large or small area fields can be achieved by changing the optics of the camera. High spatial resolution is possible by using any fluorescence microscope. © 2006 American Chemical Society.
format JOUR
author Filevich, O.
Etchenique, R.
author_facet Filevich, O.
Etchenique, R.
author_sort Filevich, O.
title 1D and 2D temperature imaging with a fluorescent ruthenium complex
title_short 1D and 2D temperature imaging with a fluorescent ruthenium complex
title_full 1D and 2D temperature imaging with a fluorescent ruthenium complex
title_fullStr 1D and 2D temperature imaging with a fluorescent ruthenium complex
title_full_unstemmed 1D and 2D temperature imaging with a fluorescent ruthenium complex
title_sort 1d and 2d temperature imaging with a fluorescent ruthenium complex
url http://hdl.handle.net/20.500.12110/paper_00032700_v78_n21_p7499_Filevich
work_keys_str_mv AT filevicho 1dand2dtemperatureimagingwithafluorescentrutheniumcomplex
AT etcheniquer 1dand2dtemperatureimagingwithafluorescentrutheniumcomplex
_version_ 1807316889223823360