Pulse Generator for Electorporation
Electroporation is widely used in biological, medical and biotechnological applications, water treatment and food industry. A pulse generator for electroporation in research environment was develop and implemented, its fundamental blocks are a Boost with autotransformer converter and an H bridge wit...
Guardado en:
Publicado: |
2018
|
---|---|
Materias: | |
Acceso en línea: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_97898746_v_n_p_Fanego http://hdl.handle.net/20.500.12110/paper_97898746_v_n_p_Fanego |
Aporte de: |
id |
paper:paper_97898746_v_n_p_Fanego |
---|---|
record_format |
dspace |
spelling |
paper:paper_97898746_v_n_p_Fanego2023-06-08T16:39:16Z Pulse Generator for Electorporation electroporation power electronic Automation Bridge circuits DC-DC converters Power electronics Process control Water treatment Biotechnological applications Design calculations Electroporation Food industries Pulse amplitude Pulse control Repetition frequency Research environment Pulse generators Electroporation is widely used in biological, medical and biotechnological applications, water treatment and food industry. A pulse generator for electroporation in research environment was develop and implemented, its fundamental blocks are a Boost with autotransformer converter and an H bridge with pulse control. The main design calculations and simulations are presented. The results of the built prototype are shown with a pulse amplitude variable between 150V and 1000 V, a pulse width variable between 10 μs and 80 ms and a repetition frequency variable between 1 Hz and 5 kHz. © 2018 Argentine Association of Automatic Control. 2018 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_97898746_v_n_p_Fanego http://hdl.handle.net/20.500.12110/paper_97898746_v_n_p_Fanego |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
electroporation power electronic Automation Bridge circuits DC-DC converters Power electronics Process control Water treatment Biotechnological applications Design calculations Electroporation Food industries Pulse amplitude Pulse control Repetition frequency Research environment Pulse generators |
spellingShingle |
electroporation power electronic Automation Bridge circuits DC-DC converters Power electronics Process control Water treatment Biotechnological applications Design calculations Electroporation Food industries Pulse amplitude Pulse control Repetition frequency Research environment Pulse generators Pulse Generator for Electorporation |
topic_facet |
electroporation power electronic Automation Bridge circuits DC-DC converters Power electronics Process control Water treatment Biotechnological applications Design calculations Electroporation Food industries Pulse amplitude Pulse control Repetition frequency Research environment Pulse generators |
description |
Electroporation is widely used in biological, medical and biotechnological applications, water treatment and food industry. A pulse generator for electroporation in research environment was develop and implemented, its fundamental blocks are a Boost with autotransformer converter and an H bridge with pulse control. The main design calculations and simulations are presented. The results of the built prototype are shown with a pulse amplitude variable between 150V and 1000 V, a pulse width variable between 10 μs and 80 ms and a repetition frequency variable between 1 Hz and 5 kHz. © 2018 Argentine Association of Automatic Control. |
title |
Pulse Generator for Electorporation |
title_short |
Pulse Generator for Electorporation |
title_full |
Pulse Generator for Electorporation |
title_fullStr |
Pulse Generator for Electorporation |
title_full_unstemmed |
Pulse Generator for Electorporation |
title_sort |
pulse generator for electorporation |
publishDate |
2018 |
url |
https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_97898746_v_n_p_Fanego http://hdl.handle.net/20.500.12110/paper_97898746_v_n_p_Fanego |
_version_ |
1769175845295882240 |