Influence of the dynamics of ions in the admittance of a modulated corona discharge

We present an experimental study of the dynamic impedance in a positive corona discharge that operates as an acoustic transducer. Since the standard equivalent circuits failed to match our experimental results, we considered transit time dependant components. The transit time is determined by the el...

Descripción completa

Detalles Bibliográficos
Publicado: 2014
Materias:
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_97814799_v_n_p338_Gomez
http://hdl.handle.net/20.500.12110/paper_97814799_v_n_p338_Gomez
Aporte de:
id paper:paper_97814799_v_n_p338_Gomez
record_format dspace
spelling paper:paper_97814799_v_n_p338_Gomez2023-06-08T16:37:47Z Influence of the dynamics of ions in the admittance of a modulated corona discharge Equivalent circuits Mica Corona discharges Dynamic conductance Dynamic impedance Good correlations Input admittance Input impedance Positive corona Vacuum diodes Electric corona We present an experimental study of the dynamic impedance in a positive corona discharge that operates as an acoustic transducer. Since the standard equivalent circuits failed to match our experimental results, we considered transit time dependant components. The transit time is determined by the elapsed time since a carrier leaves one electrode until it reaches the other. From the equations that describe the dynamics of the ions in the discharge, we found similarities with the behavior of a vacuum diode whose input impedance is mainly determined by the transit time. Based on this approach we were able to match our experimental results with the equivalent circuit by adjusting the transit time, which in turn determines the admittance. The transit time and the direct current density allow computing the carrier density which presents good correlation with the dynamic conductance. This way, we show the method is self-consistent and that the transit time influences the corona discharge input admittance. © 2014 IEEE. 2014 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_97814799_v_n_p338_Gomez http://hdl.handle.net/20.500.12110/paper_97814799_v_n_p338_Gomez
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Equivalent circuits
Mica
Corona discharges
Dynamic conductance
Dynamic impedance
Good correlations
Input admittance
Input impedance
Positive corona
Vacuum diodes
Electric corona
spellingShingle Equivalent circuits
Mica
Corona discharges
Dynamic conductance
Dynamic impedance
Good correlations
Input admittance
Input impedance
Positive corona
Vacuum diodes
Electric corona
Influence of the dynamics of ions in the admittance of a modulated corona discharge
topic_facet Equivalent circuits
Mica
Corona discharges
Dynamic conductance
Dynamic impedance
Good correlations
Input admittance
Input impedance
Positive corona
Vacuum diodes
Electric corona
description We present an experimental study of the dynamic impedance in a positive corona discharge that operates as an acoustic transducer. Since the standard equivalent circuits failed to match our experimental results, we considered transit time dependant components. The transit time is determined by the elapsed time since a carrier leaves one electrode until it reaches the other. From the equations that describe the dynamics of the ions in the discharge, we found similarities with the behavior of a vacuum diode whose input impedance is mainly determined by the transit time. Based on this approach we were able to match our experimental results with the equivalent circuit by adjusting the transit time, which in turn determines the admittance. The transit time and the direct current density allow computing the carrier density which presents good correlation with the dynamic conductance. This way, we show the method is self-consistent and that the transit time influences the corona discharge input admittance. © 2014 IEEE.
title Influence of the dynamics of ions in the admittance of a modulated corona discharge
title_short Influence of the dynamics of ions in the admittance of a modulated corona discharge
title_full Influence of the dynamics of ions in the admittance of a modulated corona discharge
title_fullStr Influence of the dynamics of ions in the admittance of a modulated corona discharge
title_full_unstemmed Influence of the dynamics of ions in the admittance of a modulated corona discharge
title_sort influence of the dynamics of ions in the admittance of a modulated corona discharge
publishDate 2014
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_97814799_v_n_p338_Gomez
http://hdl.handle.net/20.500.12110/paper_97814799_v_n_p338_Gomez
_version_ 1768543728330342400