UV-MALDI-TOF MS analysis of carbohydrates. reviewing comparative studies performed using nor-harmane and classical UV-MALDI matrices
In an effort to gain an understanding of the processes governing matrix-assisted ultraviolet laser desorption/ionization (UV-MALDI), we made a direct comparison of the mass spectra (MS) of carbohydrates (neutral cyclic and acyclic, sulfated and acid mono- and polysaccharides) by using nor-harmane an...
Guardado en:
| Autor principal: | |
|---|---|
| Publicado: |
2008
|
| Materias: | |
| Acceso en línea: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_1880554X_v46_n2_p65_ErraBalsells http://hdl.handle.net/20.500.12110/paper_1880554X_v46_n2_p65_ErraBalsells |
| Aporte de: |
| id |
paper:paper_1880554X_v46_n2_p65_ErraBalsells |
|---|---|
| record_format |
dspace |
| spelling |
paper:paper_1880554X_v46_n2_p65_ErraBalsells2025-07-30T19:05:57Z UV-MALDI-TOF MS analysis of carbohydrates. reviewing comparative studies performed using nor-harmane and classical UV-MALDI matrices Erra Balsells, Rosa Carrageenan Nor-harmane Pectin Polysaccharides Uv-maldi matrix UVMALDI-TOF MS Xylan In an effort to gain an understanding of the processes governing matrix-assisted ultraviolet laser desorption/ionization (UV-MALDI), we made a direct comparison of the mass spectra (MS) of carbohydrates (neutral cyclic and acyclic, sulfated and acid mono- and polysaccharides) by using nor-harmane and several classical matrices (gentisic acid (GA); 2,4,6trihydroxixyacetophenone (THAP); among others) as UV-MALDI matrices in positive and negative ion modes in linear, reflectron and post-source decay (PSD) modes. The peculiarity of norharmane is that behaves better as matrix than GA in negative ion mode. Because the initiation of the UV-MALDI process is a photochemical reaction (matrix +hv (337 or 355 nm)→ matrix*), the acid-base character of nor-harmane in the ground and the lower electronic excited singlet state, together with other photophysical properties such as prompt heat release to the medium are discussed in brief. Excellent results obtained with cyclodextrins with nor-harmane allow us to propose these analyte-matrix systems for UV-MALDI-TOF MS calibration in positive and negative ion modes in linear, reflectron and PSD modes. Fil:Erra-Balsells, R. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. 2008 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_1880554X_v46_n2_p65_ErraBalsells http://hdl.handle.net/20.500.12110/paper_1880554X_v46_n2_p65_ErraBalsells |
| institution |
Universidad de Buenos Aires |
| institution_str |
I-28 |
| repository_str |
R-134 |
| collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
| topic |
Carrageenan Nor-harmane Pectin Polysaccharides Uv-maldi matrix UVMALDI-TOF MS Xylan |
| spellingShingle |
Carrageenan Nor-harmane Pectin Polysaccharides Uv-maldi matrix UVMALDI-TOF MS Xylan Erra Balsells, Rosa UV-MALDI-TOF MS analysis of carbohydrates. reviewing comparative studies performed using nor-harmane and classical UV-MALDI matrices |
| topic_facet |
Carrageenan Nor-harmane Pectin Polysaccharides Uv-maldi matrix UVMALDI-TOF MS Xylan |
| description |
In an effort to gain an understanding of the processes governing matrix-assisted ultraviolet laser desorption/ionization (UV-MALDI), we made a direct comparison of the mass spectra (MS) of carbohydrates (neutral cyclic and acyclic, sulfated and acid mono- and polysaccharides) by using nor-harmane and several classical matrices (gentisic acid (GA); 2,4,6trihydroxixyacetophenone (THAP); among others) as UV-MALDI matrices in positive and negative ion modes in linear, reflectron and post-source decay (PSD) modes. The peculiarity of norharmane is that behaves better as matrix than GA in negative ion mode. Because the initiation of the UV-MALDI process is a photochemical reaction (matrix +hv (337 or 355 nm)→ matrix*), the acid-base character of nor-harmane in the ground and the lower electronic excited singlet state, together with other photophysical properties such as prompt heat release to the medium are discussed in brief. Excellent results obtained with cyclodextrins with nor-harmane allow us to propose these analyte-matrix systems for UV-MALDI-TOF MS calibration in positive and negative ion modes in linear, reflectron and PSD modes. |
| author |
Erra Balsells, Rosa |
| author_facet |
Erra Balsells, Rosa |
| author_sort |
Erra Balsells, Rosa |
| title |
UV-MALDI-TOF MS analysis of carbohydrates. reviewing comparative studies performed using nor-harmane and classical UV-MALDI matrices |
| title_short |
UV-MALDI-TOF MS analysis of carbohydrates. reviewing comparative studies performed using nor-harmane and classical UV-MALDI matrices |
| title_full |
UV-MALDI-TOF MS analysis of carbohydrates. reviewing comparative studies performed using nor-harmane and classical UV-MALDI matrices |
| title_fullStr |
UV-MALDI-TOF MS analysis of carbohydrates. reviewing comparative studies performed using nor-harmane and classical UV-MALDI matrices |
| title_full_unstemmed |
UV-MALDI-TOF MS analysis of carbohydrates. reviewing comparative studies performed using nor-harmane and classical UV-MALDI matrices |
| title_sort |
uv-maldi-tof ms analysis of carbohydrates. reviewing comparative studies performed using nor-harmane and classical uv-maldi matrices |
| publishDate |
2008 |
| url |
https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_1880554X_v46_n2_p65_ErraBalsells http://hdl.handle.net/20.500.12110/paper_1880554X_v46_n2_p65_ErraBalsells |
| work_keys_str_mv |
AT errabalsellsrosa uvmalditofmsanalysisofcarbohydratesreviewingcomparativestudiesperformedusingnorharmaneandclassicaluvmaldimatrices |
| _version_ |
1840323239691157504 |