Effect of ultrasound on the survival of Saccharomyces cerevisiae: Influence of temperature, pH and amplitude

The resistance of Saccharomyces cerevisiae cells to the action of ultrasound (20 kHz, wave amplitude in the range 71-110 μm) was analyzed at 35, 45 and 55°C in Sabouraud broth at pH 3.0 and 5.6. The inactivation rate where a first-order kinetic was observed exhibited D values between 0.5 and 31 min....

Descripción completa

Guardado en:
Detalles Bibliográficos
Publicado: 2001
Materias:
PH
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_14668564_v2_n1_p31_Guerrero
http://hdl.handle.net/20.500.12110/paper_14668564_v2_n1_p31_Guerrero
Aporte de:
id paper:paper_14668564_v2_n1_p31_Guerrero
record_format dspace
spelling paper:paper_14668564_v2_n1_p31_Guerrero2023-06-08T16:16:54Z Effect of ultrasound on the survival of Saccharomyces cerevisiae: Influence of temperature, pH and amplitude Amplitude Inactivation PH Saccharomyces cerevisiae Temperature Ultrasound Saccharomyces cerevisiae The resistance of Saccharomyces cerevisiae cells to the action of ultrasound (20 kHz, wave amplitude in the range 71-110 μm) was analyzed at 35, 45 and 55°C in Sabouraud broth at pH 3.0 and 5.6. The inactivation rate where a first-order kinetic was observed exhibited D values between 0.5 and 31 min. The resistance of the yeast decreased as ultrasonic wave amplitude increased, with the z values for this effect ranging between 128 and 323 μm. In the pH range investigated, the reduction of pH did not affect ultrasound yeast sensitivity except for experiments performed at 71.4 μm wave amplitude and 45°C. At moderate temperatures, decimal reduction time values were reduced by the simultaneous effect of ultrasound but at 55°C, no advantages were observed by adding sonication. Structural studies performed in cells sonicated at 45°C and 95.2 μm of wave amplitude indicated the treatment provoked puncturing of cell walls with leakage of content as well as damage at subcellular level. However, when ultrasound was applied at 55°C, no structural differences were appreciated between sonicated cells and only heat-treated cells. © 2001 Elsevier Science Ltd. 2001 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_14668564_v2_n1_p31_Guerrero http://hdl.handle.net/20.500.12110/paper_14668564_v2_n1_p31_Guerrero
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Amplitude
Inactivation
PH
Saccharomyces cerevisiae
Temperature
Ultrasound
Saccharomyces cerevisiae
spellingShingle Amplitude
Inactivation
PH
Saccharomyces cerevisiae
Temperature
Ultrasound
Saccharomyces cerevisiae
Effect of ultrasound on the survival of Saccharomyces cerevisiae: Influence of temperature, pH and amplitude
topic_facet Amplitude
Inactivation
PH
Saccharomyces cerevisiae
Temperature
Ultrasound
Saccharomyces cerevisiae
description The resistance of Saccharomyces cerevisiae cells to the action of ultrasound (20 kHz, wave amplitude in the range 71-110 μm) was analyzed at 35, 45 and 55°C in Sabouraud broth at pH 3.0 and 5.6. The inactivation rate where a first-order kinetic was observed exhibited D values between 0.5 and 31 min. The resistance of the yeast decreased as ultrasonic wave amplitude increased, with the z values for this effect ranging between 128 and 323 μm. In the pH range investigated, the reduction of pH did not affect ultrasound yeast sensitivity except for experiments performed at 71.4 μm wave amplitude and 45°C. At moderate temperatures, decimal reduction time values were reduced by the simultaneous effect of ultrasound but at 55°C, no advantages were observed by adding sonication. Structural studies performed in cells sonicated at 45°C and 95.2 μm of wave amplitude indicated the treatment provoked puncturing of cell walls with leakage of content as well as damage at subcellular level. However, when ultrasound was applied at 55°C, no structural differences were appreciated between sonicated cells and only heat-treated cells. © 2001 Elsevier Science Ltd.
title Effect of ultrasound on the survival of Saccharomyces cerevisiae: Influence of temperature, pH and amplitude
title_short Effect of ultrasound on the survival of Saccharomyces cerevisiae: Influence of temperature, pH and amplitude
title_full Effect of ultrasound on the survival of Saccharomyces cerevisiae: Influence of temperature, pH and amplitude
title_fullStr Effect of ultrasound on the survival of Saccharomyces cerevisiae: Influence of temperature, pH and amplitude
title_full_unstemmed Effect of ultrasound on the survival of Saccharomyces cerevisiae: Influence of temperature, pH and amplitude
title_sort effect of ultrasound on the survival of saccharomyces cerevisiae: influence of temperature, ph and amplitude
publishDate 2001
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_14668564_v2_n1_p31_Guerrero
http://hdl.handle.net/20.500.12110/paper_14668564_v2_n1_p31_Guerrero
_version_ 1768544837283348480