Gravimetric measurement in redox polymer electrodes with the EQCM beyond the Sauerbrey limit

Gravimetric measurements during electrochemical redox switching of an Os-containing hydrogel film in contact with aqueous electrolyte have been obtained beyond the Sauerbrey rigid mass limit of the electrochemical quartz crystal microbalance (EQCM). For an acoustically non-rigid film the frequency-t...

Descripción completa

Guardado en:
Detalles Bibliográficos
Publicado: 1999
Materias:
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_13882481_v1_n5_p167_Etchenique
http://hdl.handle.net/20.500.12110/paper_13882481_v1_n5_p167_Etchenique
Aporte de:
id paper:paper_13882481_v1_n5_p167_Etchenique
record_format dspace
spelling paper:paper_13882481_v1_n5_p167_Etchenique2023-06-08T16:13:03Z Gravimetric measurement in redox polymer electrodes with the EQCM beyond the Sauerbrey limit Acoustic wave Electrochemical quartz crystal microbalance Hydrogel Microgravimetry Quartz crystal impedance Redox polymer Sauerbrey Viscoelasticity Gravimetric measurements during electrochemical redox switching of an Os-containing hydrogel film in contact with aqueous electrolyte have been obtained beyond the Sauerbrey rigid mass limit of the electrochemical quartz crystal microbalance (EQCM). For an acoustically non-rigid film the frequency-to-mass Sauerbrey relationship is not valid and the mass has been obtained from the experimental electroacoustic impedance data collected simultaneously with electrochemical experiments interpreted using Martin's viscoelastic model. 1999 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_13882481_v1_n5_p167_Etchenique http://hdl.handle.net/20.500.12110/paper_13882481_v1_n5_p167_Etchenique
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Acoustic wave
Electrochemical quartz crystal microbalance
Hydrogel
Microgravimetry
Quartz crystal impedance
Redox polymer
Sauerbrey
Viscoelasticity
spellingShingle Acoustic wave
Electrochemical quartz crystal microbalance
Hydrogel
Microgravimetry
Quartz crystal impedance
Redox polymer
Sauerbrey
Viscoelasticity
Gravimetric measurement in redox polymer electrodes with the EQCM beyond the Sauerbrey limit
topic_facet Acoustic wave
Electrochemical quartz crystal microbalance
Hydrogel
Microgravimetry
Quartz crystal impedance
Redox polymer
Sauerbrey
Viscoelasticity
description Gravimetric measurements during electrochemical redox switching of an Os-containing hydrogel film in contact with aqueous electrolyte have been obtained beyond the Sauerbrey rigid mass limit of the electrochemical quartz crystal microbalance (EQCM). For an acoustically non-rigid film the frequency-to-mass Sauerbrey relationship is not valid and the mass has been obtained from the experimental electroacoustic impedance data collected simultaneously with electrochemical experiments interpreted using Martin's viscoelastic model.
title Gravimetric measurement in redox polymer electrodes with the EQCM beyond the Sauerbrey limit
title_short Gravimetric measurement in redox polymer electrodes with the EQCM beyond the Sauerbrey limit
title_full Gravimetric measurement in redox polymer electrodes with the EQCM beyond the Sauerbrey limit
title_fullStr Gravimetric measurement in redox polymer electrodes with the EQCM beyond the Sauerbrey limit
title_full_unstemmed Gravimetric measurement in redox polymer electrodes with the EQCM beyond the Sauerbrey limit
title_sort gravimetric measurement in redox polymer electrodes with the eqcm beyond the sauerbrey limit
publishDate 1999
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_13882481_v1_n5_p167_Etchenique
http://hdl.handle.net/20.500.12110/paper_13882481_v1_n5_p167_Etchenique
_version_ 1768543002291077120