Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors
We present a method to measure the relative spectral response of the Pierre Auger Observatory Fluorescence Detector. The calibration was done at wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in which the response of all detector components are combined in a single measur...
Guardado en:
Publicado: |
2009
|
---|---|
Materias: | |
Acceso en línea: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_09276505_v31_n4_p305_Rovero http://hdl.handle.net/20.500.12110/paper_09276505_v31_n4_p305_Rovero |
Aporte de: |
id |
paper:paper_09276505_v31_n4_p305_Rovero |
---|---|
record_format |
dspace |
spelling |
paper:paper_09276505_v31_n4_p305_Rovero2023-06-08T15:51:52Z Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors Auger Observatory Calibration Cosmic ray Extensive air shower Fluorescence detectors At wavelengths Auger Observatory Cosmic ray Detector components Extensive air shower Fluorescence detectors Multi wavelengths Pierre Auger observatories Relative spectral response Augers Buildings Calibration Cosmic rays Cosmology Detectors Light Light sources Notch filters Observatories Particle detectors Xenon Fluorescence We present a method to measure the relative spectral response of the Pierre Auger Observatory Fluorescence Detector. The calibration was done at wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in which the response of all detector components are combined in a single measurement. A xenon flasher and notch-filters were used as the light source for the calibration device. The overall uncertainty is 5%. © 2009 Elsevier B.V. All rights reserved. 2009 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_09276505_v31_n4_p305_Rovero http://hdl.handle.net/20.500.12110/paper_09276505_v31_n4_p305_Rovero |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
Auger Observatory Calibration Cosmic ray Extensive air shower Fluorescence detectors At wavelengths Auger Observatory Cosmic ray Detector components Extensive air shower Fluorescence detectors Multi wavelengths Pierre Auger observatories Relative spectral response Augers Buildings Calibration Cosmic rays Cosmology Detectors Light Light sources Notch filters Observatories Particle detectors Xenon Fluorescence |
spellingShingle |
Auger Observatory Calibration Cosmic ray Extensive air shower Fluorescence detectors At wavelengths Auger Observatory Cosmic ray Detector components Extensive air shower Fluorescence detectors Multi wavelengths Pierre Auger observatories Relative spectral response Augers Buildings Calibration Cosmic rays Cosmology Detectors Light Light sources Notch filters Observatories Particle detectors Xenon Fluorescence Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors |
topic_facet |
Auger Observatory Calibration Cosmic ray Extensive air shower Fluorescence detectors At wavelengths Auger Observatory Cosmic ray Detector components Extensive air shower Fluorescence detectors Multi wavelengths Pierre Auger observatories Relative spectral response Augers Buildings Calibration Cosmic rays Cosmology Detectors Light Light sources Notch filters Observatories Particle detectors Xenon Fluorescence |
description |
We present a method to measure the relative spectral response of the Pierre Auger Observatory Fluorescence Detector. The calibration was done at wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in which the response of all detector components are combined in a single measurement. A xenon flasher and notch-filters were used as the light source for the calibration device. The overall uncertainty is 5%. © 2009 Elsevier B.V. All rights reserved. |
title |
Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors |
title_short |
Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors |
title_full |
Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors |
title_fullStr |
Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors |
title_full_unstemmed |
Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors |
title_sort |
multi-wavelength calibration procedure for the pierre auger observatory fluorescence detectors |
publishDate |
2009 |
url |
https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_09276505_v31_n4_p305_Rovero http://hdl.handle.net/20.500.12110/paper_09276505_v31_n4_p305_Rovero |
_version_ |
1768545235853377536 |