On-line copper and iron removal and selenium(VI) pre-reduction for the determination of total selenium by flow-injection hydride generation-inductively coupled plasma optical emission spectrometry
Selenium was determined in samples with high copper and iron contents by hydride generation-inductively coupled plasma optical emission spectrometry (HG-ICP-OES) after flow-injection (FI) on-line copper and iron removal and selenium(VI) reduction. A Dowex 1X-8 anion-exchange microcolumn was used for...
Autores principales: | , , |
---|---|
Publicado: |
2001
|
Materias: | |
Acceso en línea: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_05848547_v56_n1_p93_Stripeikis http://hdl.handle.net/20.500.12110/paper_05848547_v56_n1_p93_Stripeikis |
Aporte de: |
id |
paper:paper_05848547_v56_n1_p93_Stripeikis |
---|---|
record_format |
dspace |
spelling |
paper:paper_05848547_v56_n1_p93_Stripeikis2023-06-08T15:42:45Z On-line copper and iron removal and selenium(VI) pre-reduction for the determination of total selenium by flow-injection hydride generation-inductively coupled plasma optical emission spectrometry Stripeikis, Jorge Daniel Tudino, Mabel Beatriz Troccoli, Osvaldo Enrique Hydride generation-inductively coupled plasma optical emission spectrometry (HG-ICP-OES) On-line pre-reduction On-line removal of Cu and Fe interferences Selenium determination Copper Inductively coupled plasma Iron Polytetrafluoroethylenes Spectrometry Inductively coupled plasma optical emission spectrometry Selenium Selenium was determined in samples with high copper and iron contents by hydride generation-inductively coupled plasma optical emission spectrometry (HG-ICP-OES) after flow-injection (FI) on-line copper and iron removal and selenium(VI) reduction. A Dowex 1X-8 anion-exchange microcolumn was used for the separation of selenium from copper and iron as their chloro-complexes. Se(VI) was then reduced on-line by heating a PTFE coiled reactor (150 cm long, 0.7 mm i.d.) in a 100°C water bath. After reduction of Se(VI), a 900-μl sample was injected into the carrier stream containing hydrochloric acid and sodium tetrahydroborate to generate the hydride. A limit of detection of 0.4 μg l-1 (RSD 2.3% for 20 μg l-1 selenium) was obtained. The application of the method to Geochemical Standard Reference Samples and copper metal reference materials (MBH) demonstrated that results were in good statistical accordance with certified values. © 2001 Elsevier Science B.V. Fil:Stripeikis, J. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Tudino, M. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Troccoli, O. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. 2001 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_05848547_v56_n1_p93_Stripeikis http://hdl.handle.net/20.500.12110/paper_05848547_v56_n1_p93_Stripeikis |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
Hydride generation-inductively coupled plasma optical emission spectrometry (HG-ICP-OES) On-line pre-reduction On-line removal of Cu and Fe interferences Selenium determination Copper Inductively coupled plasma Iron Polytetrafluoroethylenes Spectrometry Inductively coupled plasma optical emission spectrometry Selenium |
spellingShingle |
Hydride generation-inductively coupled plasma optical emission spectrometry (HG-ICP-OES) On-line pre-reduction On-line removal of Cu and Fe interferences Selenium determination Copper Inductively coupled plasma Iron Polytetrafluoroethylenes Spectrometry Inductively coupled plasma optical emission spectrometry Selenium Stripeikis, Jorge Daniel Tudino, Mabel Beatriz Troccoli, Osvaldo Enrique On-line copper and iron removal and selenium(VI) pre-reduction for the determination of total selenium by flow-injection hydride generation-inductively coupled plasma optical emission spectrometry |
topic_facet |
Hydride generation-inductively coupled plasma optical emission spectrometry (HG-ICP-OES) On-line pre-reduction On-line removal of Cu and Fe interferences Selenium determination Copper Inductively coupled plasma Iron Polytetrafluoroethylenes Spectrometry Inductively coupled plasma optical emission spectrometry Selenium |
description |
Selenium was determined in samples with high copper and iron contents by hydride generation-inductively coupled plasma optical emission spectrometry (HG-ICP-OES) after flow-injection (FI) on-line copper and iron removal and selenium(VI) reduction. A Dowex 1X-8 anion-exchange microcolumn was used for the separation of selenium from copper and iron as their chloro-complexes. Se(VI) was then reduced on-line by heating a PTFE coiled reactor (150 cm long, 0.7 mm i.d.) in a 100°C water bath. After reduction of Se(VI), a 900-μl sample was injected into the carrier stream containing hydrochloric acid and sodium tetrahydroborate to generate the hydride. A limit of detection of 0.4 μg l-1 (RSD 2.3% for 20 μg l-1 selenium) was obtained. The application of the method to Geochemical Standard Reference Samples and copper metal reference materials (MBH) demonstrated that results were in good statistical accordance with certified values. © 2001 Elsevier Science B.V. |
author |
Stripeikis, Jorge Daniel Tudino, Mabel Beatriz Troccoli, Osvaldo Enrique |
author_facet |
Stripeikis, Jorge Daniel Tudino, Mabel Beatriz Troccoli, Osvaldo Enrique |
author_sort |
Stripeikis, Jorge Daniel |
title |
On-line copper and iron removal and selenium(VI) pre-reduction for the determination of total selenium by flow-injection hydride generation-inductively coupled plasma optical emission spectrometry |
title_short |
On-line copper and iron removal and selenium(VI) pre-reduction for the determination of total selenium by flow-injection hydride generation-inductively coupled plasma optical emission spectrometry |
title_full |
On-line copper and iron removal and selenium(VI) pre-reduction for the determination of total selenium by flow-injection hydride generation-inductively coupled plasma optical emission spectrometry |
title_fullStr |
On-line copper and iron removal and selenium(VI) pre-reduction for the determination of total selenium by flow-injection hydride generation-inductively coupled plasma optical emission spectrometry |
title_full_unstemmed |
On-line copper and iron removal and selenium(VI) pre-reduction for the determination of total selenium by flow-injection hydride generation-inductively coupled plasma optical emission spectrometry |
title_sort |
on-line copper and iron removal and selenium(vi) pre-reduction for the determination of total selenium by flow-injection hydride generation-inductively coupled plasma optical emission spectrometry |
publishDate |
2001 |
url |
https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_05848547_v56_n1_p93_Stripeikis http://hdl.handle.net/20.500.12110/paper_05848547_v56_n1_p93_Stripeikis |
work_keys_str_mv |
AT stripeikisjorgedaniel onlinecopperandironremovalandseleniumviprereductionforthedeterminationoftotalseleniumbyflowinjectionhydridegenerationinductivelycoupledplasmaopticalemissionspectrometry AT tudinomabelbeatriz onlinecopperandironremovalandseleniumviprereductionforthedeterminationoftotalseleniumbyflowinjectionhydridegenerationinductivelycoupledplasmaopticalemissionspectrometry AT troccoliosvaldoenrique onlinecopperandironremovalandseleniumviprereductionforthedeterminationoftotalseleniumbyflowinjectionhydridegenerationinductivelycoupledplasmaopticalemissionspectrometry |
_version_ |
1768546496810057728 |