Radiographic method for measuring the continuum hard X-ray output spectrum of a Plasma Focus device
A radiographic method is proposed and then applied to infer the continuum part of the hard X-ray spectrum of a 4.7 kJ Plasma Focus from differential absorption measurements on metals. Copper, nickel, titanium and silver samples with thicknesses spanning between 0.1 and 10 mm were employed as filters...
Guardado en:
Autores principales: | , |
---|---|
Publicado: |
2009
|
Materias: | |
Acceso en línea: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03759601_v373_n40_p3659_Raspa http://hdl.handle.net/20.500.12110/paper_03759601_v373_n40_p3659_Raspa |
Aporte de: |
id |
paper:paper_03759601_v373_n40_p3659_Raspa |
---|---|
record_format |
dspace |
spelling |
paper:paper_03759601_v373_n40_p3659_Raspa2023-06-08T15:38:42Z Radiographic method for measuring the continuum hard X-ray output spectrum of a Plasma Focus device Raspa, Verónica Moreno, Cesar Hugo Hard X-ray spectrum Plasma Focus Plasma hard X-ray sources Radiographic method A radiographic method is proposed and then applied to infer the continuum part of the hard X-ray spectrum of a 4.7 kJ Plasma Focus from differential absorption measurements on metals. Copper, nickel, titanium and silver samples with thicknesses spanning between 0.1 and 10 mm were employed as filters. The X-ray radiation was detected using a standard radiographic screen-film system. The results show the presence of a dominant peak around 75 keV with significant spectral components in the range of 40 to 200 keV. The method is easy to follow, inexpensive, and allows for calibrated, single shot, spectral measurements. © 2009 Elsevier B.V. All rights reserved. Fil:Raspa, V. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Moreno, C. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. 2009 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03759601_v373_n40_p3659_Raspa http://hdl.handle.net/20.500.12110/paper_03759601_v373_n40_p3659_Raspa |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
Hard X-ray spectrum Plasma Focus Plasma hard X-ray sources Radiographic method |
spellingShingle |
Hard X-ray spectrum Plasma Focus Plasma hard X-ray sources Radiographic method Raspa, Verónica Moreno, Cesar Hugo Radiographic method for measuring the continuum hard X-ray output spectrum of a Plasma Focus device |
topic_facet |
Hard X-ray spectrum Plasma Focus Plasma hard X-ray sources Radiographic method |
description |
A radiographic method is proposed and then applied to infer the continuum part of the hard X-ray spectrum of a 4.7 kJ Plasma Focus from differential absorption measurements on metals. Copper, nickel, titanium and silver samples with thicknesses spanning between 0.1 and 10 mm were employed as filters. The X-ray radiation was detected using a standard radiographic screen-film system. The results show the presence of a dominant peak around 75 keV with significant spectral components in the range of 40 to 200 keV. The method is easy to follow, inexpensive, and allows for calibrated, single shot, spectral measurements. © 2009 Elsevier B.V. All rights reserved. |
author |
Raspa, Verónica Moreno, Cesar Hugo |
author_facet |
Raspa, Verónica Moreno, Cesar Hugo |
author_sort |
Raspa, Verónica |
title |
Radiographic method for measuring the continuum hard X-ray output spectrum of a Plasma Focus device |
title_short |
Radiographic method for measuring the continuum hard X-ray output spectrum of a Plasma Focus device |
title_full |
Radiographic method for measuring the continuum hard X-ray output spectrum of a Plasma Focus device |
title_fullStr |
Radiographic method for measuring the continuum hard X-ray output spectrum of a Plasma Focus device |
title_full_unstemmed |
Radiographic method for measuring the continuum hard X-ray output spectrum of a Plasma Focus device |
title_sort |
radiographic method for measuring the continuum hard x-ray output spectrum of a plasma focus device |
publishDate |
2009 |
url |
https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03759601_v373_n40_p3659_Raspa http://hdl.handle.net/20.500.12110/paper_03759601_v373_n40_p3659_Raspa |
work_keys_str_mv |
AT raspaveronica radiographicmethodformeasuringthecontinuumhardxrayoutputspectrumofaplasmafocusdevice AT morenocesarhugo radiographicmethodformeasuringthecontinuumhardxrayoutputspectrumofaplasmafocusdevice |
_version_ |
1768545331820101632 |