K-X-Ray-γ directional correlations in the decay of54Mn,65Zn,75Se,85Sr,133Ba and207Bi

K-X-ray-γ directional correlations following the decay of54Mn,65Zn,75Se,85Sr,133Ba and207Bi have been performed. The experimental set-up consisted of a set of four scintillation counters, one for detecting X-rays and the three others for detecting γ-rays, placed at 90°, 180° and 270° with respect to...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Bosch, Horacio Ernesto, Behar, D. Moni, García Bermudez, Gerardo José
Publicado: 1971
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03693546_v6_n4_p576_Bosch
http://hdl.handle.net/20.500.12110/paper_03693546_v6_n4_p576_Bosch
Aporte de:
id paper:paper_03693546_v6_n4_p576_Bosch
record_format dspace
spelling paper:paper_03693546_v6_n4_p576_Bosch2023-06-08T15:36:15Z K-X-Ray-γ directional correlations in the decay of54Mn,65Zn,75Se,85Sr,133Ba and207Bi Bosch, Horacio Ernesto Behar, D. Moni García Bermudez, Gerardo José K-X-ray-γ directional correlations following the decay of54Mn,65Zn,75Se,85Sr,133Ba and207Bi have been performed. The experimental set-up consisted of a set of four scintillation counters, one for detecting X-rays and the three others for detecting γ-rays, placed at 90°, 180° and 270° with respect to the source to X-ray detector direction. Multiple coincidence units and a logic system were used in order to display three X-ray spectra in three 128-channel submemories of a 512-channel analyser, corresponding to coincidences between X-rays and γ-rays detected in each counter, respectively. For the case of the133Ba X-γ angular correlation, the scintillation counters were replaced by one Ge(Li) detector in order to select with high resolution the γ-ray of 356 keV. Corrections for chance coincidences were made and a χ2-test of the data was performed. From the K-X-γ directional correlations following the above-mentioned decays a value of the anisotropy was derived. In all cases this value is consistent with zero, to within a one percent error. These results are in agreement with the theoretical predictions of Dolginov. A discrepancy with the anisotropy value reported by Perepelkin appeared. The values corresponding to the decays of65Zn,85Sr and133Ba are consistent with the ones reported by Ramaswamy and McDonnell and Ramaswany. © 1971 Società Italiana di Fisica. Fil:Bosch, H.E. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Behar, M. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:García Bermudez, G. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. 1971 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03693546_v6_n4_p576_Bosch http://hdl.handle.net/20.500.12110/paper_03693546_v6_n4_p576_Bosch
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
description K-X-ray-γ directional correlations following the decay of54Mn,65Zn,75Se,85Sr,133Ba and207Bi have been performed. The experimental set-up consisted of a set of four scintillation counters, one for detecting X-rays and the three others for detecting γ-rays, placed at 90°, 180° and 270° with respect to the source to X-ray detector direction. Multiple coincidence units and a logic system were used in order to display three X-ray spectra in three 128-channel submemories of a 512-channel analyser, corresponding to coincidences between X-rays and γ-rays detected in each counter, respectively. For the case of the133Ba X-γ angular correlation, the scintillation counters were replaced by one Ge(Li) detector in order to select with high resolution the γ-ray of 356 keV. Corrections for chance coincidences were made and a χ2-test of the data was performed. From the K-X-γ directional correlations following the above-mentioned decays a value of the anisotropy was derived. In all cases this value is consistent with zero, to within a one percent error. These results are in agreement with the theoretical predictions of Dolginov. A discrepancy with the anisotropy value reported by Perepelkin appeared. The values corresponding to the decays of65Zn,85Sr and133Ba are consistent with the ones reported by Ramaswamy and McDonnell and Ramaswany. © 1971 Società Italiana di Fisica.
author Bosch, Horacio Ernesto
Behar, D. Moni
García Bermudez, Gerardo José
spellingShingle Bosch, Horacio Ernesto
Behar, D. Moni
García Bermudez, Gerardo José
K-X-Ray-γ directional correlations in the decay of54Mn,65Zn,75Se,85Sr,133Ba and207Bi
author_facet Bosch, Horacio Ernesto
Behar, D. Moni
García Bermudez, Gerardo José
author_sort Bosch, Horacio Ernesto
title K-X-Ray-γ directional correlations in the decay of54Mn,65Zn,75Se,85Sr,133Ba and207Bi
title_short K-X-Ray-γ directional correlations in the decay of54Mn,65Zn,75Se,85Sr,133Ba and207Bi
title_full K-X-Ray-γ directional correlations in the decay of54Mn,65Zn,75Se,85Sr,133Ba and207Bi
title_fullStr K-X-Ray-γ directional correlations in the decay of54Mn,65Zn,75Se,85Sr,133Ba and207Bi
title_full_unstemmed K-X-Ray-γ directional correlations in the decay of54Mn,65Zn,75Se,85Sr,133Ba and207Bi
title_sort k-x-ray-γ directional correlations in the decay of54mn,65zn,75se,85sr,133ba and207bi
publishDate 1971
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03693546_v6_n4_p576_Bosch
http://hdl.handle.net/20.500.12110/paper_03693546_v6_n4_p576_Bosch
work_keys_str_mv AT boschhoracioernesto kxraygdirectionalcorrelationsinthedecayof54mn65zn75se85sr133baand207bi
AT behardmoni kxraygdirectionalcorrelationsinthedecayof54mn65zn75se85sr133baand207bi
AT garciabermudezgerardojose kxraygdirectionalcorrelationsinthedecayof54mn65zn75se85sr133baand207bi
_version_ 1768545053175709696