Electrical resistivity tomography applied to the characterization of contaminated sites at dairies

Groundwater quality at dairies, used for animal consumption, may have incidence on milk quality, for which it is important to know the effect of wastes lixiviation on soil and groundwater. The aim was to detect anomalies of electrical conductivity at non saturated and saturated zone, by means of ele...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Losinno, Beatriz Norma, Sainato, Claudia Mabel
Publicado: 2008
Materias:
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03263169_v26_n2_p141_Losinno
http://hdl.handle.net/20.500.12110/paper_03263169_v26_n2_p141_Losinno
Aporte de:
id paper:paper_03263169_v26_n2_p141_Losinno
record_format dspace
spelling paper:paper_03263169_v26_n2_p141_Losinno2023-06-08T15:33:03Z Electrical resistivity tomography applied to the characterization of contaminated sites at dairies Losinno, Beatriz Norma Sainato, Claudia Mabel Contamination Dairy farm Electrical resistivity tomography Groundwater Soils Animalia Groundwater quality at dairies, used for animal consumption, may have incidence on milk quality, for which it is important to know the effect of wastes lixiviation on soil and groundwater. The aim was to detect anomalies of electrical conductivity at non saturated and saturated zone, by means of electrical resistivity tomography, at potentially contaminated sites at two dairies at Venado Tuerto (Santa Fe Province, Argentina) and at Carmen de Areco (Buenos Aires Province, Argentina), and its relationship with physico-chemical properties of soil and groundwater. In Carmen de Areco, a silty laomy soil with clay horizon (Bt), the most critical site, the corral near the milking house had an anomaly of electrical conductivity of 60% at non saturated zone relative to the background soundings, while the feeding zone which is periodically moved within the lots was not affected.In Venado Tuerto, a sandy loamy soil of thicker texture, the feeding zone with an anomaly of 84% and an animal charge prolonged in time, and the surroundings of the lagoon of effluents had great content of salts. In both cases, the salinity was associated with high concentration of nitrates, phosphorous and sulphates from the animal effluents. Fil:Losinno, B.N. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Sainato, C.M. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. 2008 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03263169_v26_n2_p141_Losinno http://hdl.handle.net/20.500.12110/paper_03263169_v26_n2_p141_Losinno
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Contamination
Dairy farm
Electrical resistivity tomography
Groundwater
Soils
Animalia
spellingShingle Contamination
Dairy farm
Electrical resistivity tomography
Groundwater
Soils
Animalia
Losinno, Beatriz Norma
Sainato, Claudia Mabel
Electrical resistivity tomography applied to the characterization of contaminated sites at dairies
topic_facet Contamination
Dairy farm
Electrical resistivity tomography
Groundwater
Soils
Animalia
description Groundwater quality at dairies, used for animal consumption, may have incidence on milk quality, for which it is important to know the effect of wastes lixiviation on soil and groundwater. The aim was to detect anomalies of electrical conductivity at non saturated and saturated zone, by means of electrical resistivity tomography, at potentially contaminated sites at two dairies at Venado Tuerto (Santa Fe Province, Argentina) and at Carmen de Areco (Buenos Aires Province, Argentina), and its relationship with physico-chemical properties of soil and groundwater. In Carmen de Areco, a silty laomy soil with clay horizon (Bt), the most critical site, the corral near the milking house had an anomaly of electrical conductivity of 60% at non saturated zone relative to the background soundings, while the feeding zone which is periodically moved within the lots was not affected.In Venado Tuerto, a sandy loamy soil of thicker texture, the feeding zone with an anomaly of 84% and an animal charge prolonged in time, and the surroundings of the lagoon of effluents had great content of salts. In both cases, the salinity was associated with high concentration of nitrates, phosphorous and sulphates from the animal effluents.
author Losinno, Beatriz Norma
Sainato, Claudia Mabel
author_facet Losinno, Beatriz Norma
Sainato, Claudia Mabel
author_sort Losinno, Beatriz Norma
title Electrical resistivity tomography applied to the characterization of contaminated sites at dairies
title_short Electrical resistivity tomography applied to the characterization of contaminated sites at dairies
title_full Electrical resistivity tomography applied to the characterization of contaminated sites at dairies
title_fullStr Electrical resistivity tomography applied to the characterization of contaminated sites at dairies
title_full_unstemmed Electrical resistivity tomography applied to the characterization of contaminated sites at dairies
title_sort electrical resistivity tomography applied to the characterization of contaminated sites at dairies
publishDate 2008
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03263169_v26_n2_p141_Losinno
http://hdl.handle.net/20.500.12110/paper_03263169_v26_n2_p141_Losinno
work_keys_str_mv AT losinnobeatriznorma electricalresistivitytomographyappliedtothecharacterizationofcontaminatedsitesatdairies
AT sainatoclaudiamabel electricalresistivitytomographyappliedtothecharacterizationofcontaminatedsitesatdairies
_version_ 1768542364574416896