The fluorescence detector of the Pierre Auger Observatory
The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector...
Guardado en:
Publicado: |
2010
|
---|---|
Materias: | |
Acceso en línea: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_01689002_v620_n2-3_p227_Multitudinario http://hdl.handle.net/20.500.12110/paper_01689002_v620_n2-3_p227_Multitudinario |
Aporte de: |
id |
paper:paper_01689002_v620_n2-3_p227_Multitudinario |
---|---|
record_format |
dspace |
spelling |
paper:paper_01689002_v620_n2-3_p227_Multitudinario2023-06-08T15:18:02Z The fluorescence detector of the Pierre Auger Observatory Cosmic rays Fluorescence detector Augers Charged particles Cosmic ray detectors Cosmic rays Cosmology Observatories Optical systems Absolute calibration Cosmic ray air showers Detector performance Fluorescence detector Hybrid detectors Pierre Auger observatory Secondary particles Ultra high-energy cosmic rays Fluorescence The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions. © 2010 Elsevier B.V. All rights reserved. 2010 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_01689002_v620_n2-3_p227_Multitudinario http://hdl.handle.net/20.500.12110/paper_01689002_v620_n2-3_p227_Multitudinario |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
Cosmic rays Fluorescence detector Augers Charged particles Cosmic ray detectors Cosmic rays Cosmology Observatories Optical systems Absolute calibration Cosmic ray air showers Detector performance Fluorescence detector Hybrid detectors Pierre Auger observatory Secondary particles Ultra high-energy cosmic rays Fluorescence |
spellingShingle |
Cosmic rays Fluorescence detector Augers Charged particles Cosmic ray detectors Cosmic rays Cosmology Observatories Optical systems Absolute calibration Cosmic ray air showers Detector performance Fluorescence detector Hybrid detectors Pierre Auger observatory Secondary particles Ultra high-energy cosmic rays Fluorescence The fluorescence detector of the Pierre Auger Observatory |
topic_facet |
Cosmic rays Fluorescence detector Augers Charged particles Cosmic ray detectors Cosmic rays Cosmology Observatories Optical systems Absolute calibration Cosmic ray air showers Detector performance Fluorescence detector Hybrid detectors Pierre Auger observatory Secondary particles Ultra high-energy cosmic rays Fluorescence |
description |
The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions. © 2010 Elsevier B.V. All rights reserved. |
title |
The fluorescence detector of the Pierre Auger Observatory |
title_short |
The fluorescence detector of the Pierre Auger Observatory |
title_full |
The fluorescence detector of the Pierre Auger Observatory |
title_fullStr |
The fluorescence detector of the Pierre Auger Observatory |
title_full_unstemmed |
The fluorescence detector of the Pierre Auger Observatory |
title_sort |
fluorescence detector of the pierre auger observatory |
publishDate |
2010 |
url |
https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_01689002_v620_n2-3_p227_Multitudinario http://hdl.handle.net/20.500.12110/paper_01689002_v620_n2-3_p227_Multitudinario |
_version_ |
1768542455336009728 |