Langmuir probe measurements in a time-fluctuating-highly ionized non-equilibrium cutting arc: Analysis of the electron retarding part of the time-averaged current-voltage characteristic of the probe

This work describes the application of Langmuir probe diagnostics to the measurement of the electron temperature in a time-fluctuating-highly ionized, non-equilibrium cutting arc. The electron retarding part of the time-averaged current-voltage characteristic of the probe was analysed, assuming that...

Descripción completa

Detalles Bibliográficos
Autor principal: Kelly, Héctor Juan
Publicado: 2013
Materias:
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00346748_v84_n12_p_Prevosto
http://hdl.handle.net/20.500.12110/paper_00346748_v84_n12_p_Prevosto
Aporte de:
id paper:paper_00346748_v84_n12_p_Prevosto
record_format dspace
spelling paper:paper_00346748_v84_n12_p_Prevosto2023-06-08T15:00:53Z Langmuir probe measurements in a time-fluctuating-highly ionized non-equilibrium cutting arc: Analysis of the electron retarding part of the time-averaged current-voltage characteristic of the probe Kelly, Héctor Juan Collision-free plasma Electron currents Exponential expression Fluctuation analysis Langmuir probe diagnostics Langmuir probe measurements Local thermal equilibrium Plasma fluctuations Ionization Langmuir probes Probes Electron temperature This work describes the application of Langmuir probe diagnostics to the measurement of the electron temperature in a time-fluctuating-highly ionized, non-equilibrium cutting arc. The electron retarding part of the time-averaged current-voltage characteristic of the probe was analysed, assuming that the standard exponential expression describing the electron current to the probe in collision-free plasmas can be applied under the investigated conditions. A procedure is described which allows the determination of the errors introduced in time-averaged probe data due to small-amplitude plasma fluctuations. It was found that the experimental points can be gathered into two well defined groups allowing defining two quite different averaged electron temperature values. In the low-current region the averaged characteristic was not significantly disturbed by the fluctuations and can reliably be used to obtain the actual value of the averaged electron temperature. In particular, an averaged electron temperature of 0.98 ± 0.07 eV (= 11400 ± 800 K) was found for the central core of the arc (30 A) at 3.5 mm downstream from the nozzle exit. This average included not only a time-average over the time fluctuations but also a spatial-average along the probe collecting length. The fitting of the high-current region of the characteristic using such electron temperature value together with the corrections given by the fluctuation analysis showed a relevant departure of local thermal equilibrium in the arc core. © 2013 AIP Publishing LLC. Fil:Kelly, H. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. 2013 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00346748_v84_n12_p_Prevosto http://hdl.handle.net/20.500.12110/paper_00346748_v84_n12_p_Prevosto
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Collision-free plasma
Electron currents
Exponential expression
Fluctuation analysis
Langmuir probe diagnostics
Langmuir probe measurements
Local thermal equilibrium
Plasma fluctuations
Ionization
Langmuir probes
Probes
Electron temperature
spellingShingle Collision-free plasma
Electron currents
Exponential expression
Fluctuation analysis
Langmuir probe diagnostics
Langmuir probe measurements
Local thermal equilibrium
Plasma fluctuations
Ionization
Langmuir probes
Probes
Electron temperature
Kelly, Héctor Juan
Langmuir probe measurements in a time-fluctuating-highly ionized non-equilibrium cutting arc: Analysis of the electron retarding part of the time-averaged current-voltage characteristic of the probe
topic_facet Collision-free plasma
Electron currents
Exponential expression
Fluctuation analysis
Langmuir probe diagnostics
Langmuir probe measurements
Local thermal equilibrium
Plasma fluctuations
Ionization
Langmuir probes
Probes
Electron temperature
description This work describes the application of Langmuir probe diagnostics to the measurement of the electron temperature in a time-fluctuating-highly ionized, non-equilibrium cutting arc. The electron retarding part of the time-averaged current-voltage characteristic of the probe was analysed, assuming that the standard exponential expression describing the electron current to the probe in collision-free plasmas can be applied under the investigated conditions. A procedure is described which allows the determination of the errors introduced in time-averaged probe data due to small-amplitude plasma fluctuations. It was found that the experimental points can be gathered into two well defined groups allowing defining two quite different averaged electron temperature values. In the low-current region the averaged characteristic was not significantly disturbed by the fluctuations and can reliably be used to obtain the actual value of the averaged electron temperature. In particular, an averaged electron temperature of 0.98 ± 0.07 eV (= 11400 ± 800 K) was found for the central core of the arc (30 A) at 3.5 mm downstream from the nozzle exit. This average included not only a time-average over the time fluctuations but also a spatial-average along the probe collecting length. The fitting of the high-current region of the characteristic using such electron temperature value together with the corrections given by the fluctuation analysis showed a relevant departure of local thermal equilibrium in the arc core. © 2013 AIP Publishing LLC.
author Kelly, Héctor Juan
author_facet Kelly, Héctor Juan
author_sort Kelly, Héctor Juan
title Langmuir probe measurements in a time-fluctuating-highly ionized non-equilibrium cutting arc: Analysis of the electron retarding part of the time-averaged current-voltage characteristic of the probe
title_short Langmuir probe measurements in a time-fluctuating-highly ionized non-equilibrium cutting arc: Analysis of the electron retarding part of the time-averaged current-voltage characteristic of the probe
title_full Langmuir probe measurements in a time-fluctuating-highly ionized non-equilibrium cutting arc: Analysis of the electron retarding part of the time-averaged current-voltage characteristic of the probe
title_fullStr Langmuir probe measurements in a time-fluctuating-highly ionized non-equilibrium cutting arc: Analysis of the electron retarding part of the time-averaged current-voltage characteristic of the probe
title_full_unstemmed Langmuir probe measurements in a time-fluctuating-highly ionized non-equilibrium cutting arc: Analysis of the electron retarding part of the time-averaged current-voltage characteristic of the probe
title_sort langmuir probe measurements in a time-fluctuating-highly ionized non-equilibrium cutting arc: analysis of the electron retarding part of the time-averaged current-voltage characteristic of the probe
publishDate 2013
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00346748_v84_n12_p_Prevosto
http://hdl.handle.net/20.500.12110/paper_00346748_v84_n12_p_Prevosto
work_keys_str_mv AT kellyhectorjuan langmuirprobemeasurementsinatimefluctuatinghighlyionizednonequilibriumcuttingarcanalysisoftheelectronretardingpartofthetimeaveragedcurrentvoltagecharacteristicoftheprobe
_version_ 1768544993573601280