Susceptibility to SCC of FeCrNi alloys in 1M HCl solution
Using the slow strain rate (SSR) technique, cracks have been observed in type AISI 310 stainless steel and Incoloy 800 wires, stressed in 1M HCl solution at room temperature, in a narrow potential range around the respective corrosion potentials. Generalized attack has been found in the Inconel 600...
Guardado en:
Publicado: |
1991
|
---|---|
Materias: | |
Acceso en línea: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_0010938X_v32_n12_p1391_Martinez http://hdl.handle.net/20.500.12110/paper_0010938X_v32_n12_p1391_Martinez |
Aporte de: |
id |
paper:paper_0010938X_v32_n12_p1391_Martinez |
---|---|
record_format |
dspace |
spelling |
paper:paper_0010938X_v32_n12_p1391_Martinez2025-07-30T17:17:37Z Susceptibility to SCC of FeCrNi alloys in 1M HCl solution Corrosion - Stress Corrosion Cracking Hydrochloric Acid - Corrosive Effects Stainless Steel - Corrosion Steel Corrosion Incoloy 800 Slow Strain Rate Technique Stainless Steel AISI 310 Iron Chromium Nickel Alloys Using the slow strain rate (SSR) technique, cracks have been observed in type AISI 310 stainless steel and Incoloy 800 wires, stressed in 1M HCl solution at room temperature, in a narrow potential range around the respective corrosion potentials. Generalized attack has been found in the Inconel 600 samples. XPS analysis showed the presence of chloride in the corrosion products of AISI 310 and Incoloy 800 wires. © 1991. 1991 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_0010938X_v32_n12_p1391_Martinez http://hdl.handle.net/20.500.12110/paper_0010938X_v32_n12_p1391_Martinez |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
Corrosion - Stress Corrosion Cracking Hydrochloric Acid - Corrosive Effects Stainless Steel - Corrosion Steel Corrosion Incoloy 800 Slow Strain Rate Technique Stainless Steel AISI 310 Iron Chromium Nickel Alloys |
spellingShingle |
Corrosion - Stress Corrosion Cracking Hydrochloric Acid - Corrosive Effects Stainless Steel - Corrosion Steel Corrosion Incoloy 800 Slow Strain Rate Technique Stainless Steel AISI 310 Iron Chromium Nickel Alloys Susceptibility to SCC of FeCrNi alloys in 1M HCl solution |
topic_facet |
Corrosion - Stress Corrosion Cracking Hydrochloric Acid - Corrosive Effects Stainless Steel - Corrosion Steel Corrosion Incoloy 800 Slow Strain Rate Technique Stainless Steel AISI 310 Iron Chromium Nickel Alloys |
description |
Using the slow strain rate (SSR) technique, cracks have been observed in type AISI 310 stainless steel and Incoloy 800 wires, stressed in 1M HCl solution at room temperature, in a narrow potential range around the respective corrosion potentials. Generalized attack has been found in the Inconel 600 samples. XPS analysis showed the presence of chloride in the corrosion products of AISI 310 and Incoloy 800 wires. © 1991. |
title |
Susceptibility to SCC of FeCrNi alloys in 1M HCl solution |
title_short |
Susceptibility to SCC of FeCrNi alloys in 1M HCl solution |
title_full |
Susceptibility to SCC of FeCrNi alloys in 1M HCl solution |
title_fullStr |
Susceptibility to SCC of FeCrNi alloys in 1M HCl solution |
title_full_unstemmed |
Susceptibility to SCC of FeCrNi alloys in 1M HCl solution |
title_sort |
susceptibility to scc of fecrni alloys in 1m hcl solution |
publishDate |
1991 |
url |
https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_0010938X_v32_n12_p1391_Martinez http://hdl.handle.net/20.500.12110/paper_0010938X_v32_n12_p1391_Martinez |
_version_ |
1840327705038422016 |