Determination of the energetic value of fruit and milk-based beverages through partial-least-squares attenuated total reflectance-Fourier transform infrared spectrometry

The estimation of important nutritional parameters, such as carbohydrates content and energetic value (calories) in commercially available fruit juice and flavour milk shakes has been made by attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) using a partial-least-square...

Descripción completa

Detalles Bibliográficos
Publicado: 2005
Materias:
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00032670_v538_n1-2_p181_Moros
http://hdl.handle.net/20.500.12110/paper_00032670_v538_n1-2_p181_Moros
Aporte de:
id paper:paper_00032670_v538_n1-2_p181_Moros
record_format dspace
spelling paper:paper_00032670_v538_n1-2_p181_Moros2023-06-08T14:23:59Z Determination of the energetic value of fruit and milk-based beverages through partial-least-squares attenuated total reflectance-Fourier transform infrared spectrometry Attenuated total reflectance Carbohydrates determination Fruit juice Hierarchical cluster analysis Infrared Milk Milk shake Partial-least-squares Attenuation Beverages Carbohydrates Fourier transform infrared spectroscopy Least squares approximations Marketing Reflection Energetic value Partial-least-squares (PLS) Root-mean-square error of prediction (RMSEP) Standard deviation Fruits analytical error article beverage calibration carbohydrate analysis cluster analysis data analysis energy food analysis food and drug administration fruit infrared spectroscopy methodology milk prediction priority journal reflectometry reproducibility sampling standard validation process Attenuated Total Reflection Attenuation Beverages Carbohydrates Fruits Marketing Reflection The estimation of important nutritional parameters, such as carbohydrates content and energetic value (calories) in commercially available fruit juice and flavour milk shakes has been made by attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) using a partial-least-square (PLS) calibration approach. A highly heterogeneous population of 65 samples obtained from the Spanish market, covering fruit juices, flavour milk shakes and milk-added fruit juices was used. The spectral range and the size of the calibration set for building the PLS model have been evaluated. Considering a calibration set comprised of 27 samples, selected via hierarchical cluster analysis, and a validation data set of 38 samples, the absolute mean difference (dx-y) and standard deviation of mean differences (sx-y) of the total carbohydrate content were 0.06 and 0.66 g/100 mL, respectively. The reproducibility of this determination established as the mean standard deviation of each triplicate analysis was 0.05 g/100 mL. In the case of energetic value, the dx-y and sx-y were 2.8 and 18 kJ/100 mL, respectively. The reproducibility of this determination corresponded to a standard deviation of 2.4 kJ/100 mL, for three replicate analyses. The root-mean-square error of prediction (RMSEP) was 18.4 kJ/100 mL and 0.72 g/100 mL for energetic value and total carbohydrates, respectively. The developed methodology favourably compares with that reported in previous works in much restricted sample composition and provided figures of merit which agree with the US-FDA statuary tolerance values. © 2005 Elsevier B.V. All rights reserved. 2005 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00032670_v538_n1-2_p181_Moros http://hdl.handle.net/20.500.12110/paper_00032670_v538_n1-2_p181_Moros
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Attenuated total reflectance
Carbohydrates determination
Fruit juice
Hierarchical cluster analysis
Infrared
Milk
Milk shake
Partial-least-squares
Attenuation
Beverages
Carbohydrates
Fourier transform infrared spectroscopy
Least squares approximations
Marketing
Reflection
Energetic value
Partial-least-squares (PLS)
Root-mean-square error of prediction (RMSEP)
Standard deviation
Fruits
analytical error
article
beverage
calibration
carbohydrate analysis
cluster analysis
data analysis
energy
food analysis
food and drug administration
fruit
infrared spectroscopy
methodology
milk
prediction
priority journal
reflectometry
reproducibility
sampling
standard
validation process
Attenuated Total Reflection
Attenuation
Beverages
Carbohydrates
Fruits
Marketing
Reflection
spellingShingle Attenuated total reflectance
Carbohydrates determination
Fruit juice
Hierarchical cluster analysis
Infrared
Milk
Milk shake
Partial-least-squares
Attenuation
Beverages
Carbohydrates
Fourier transform infrared spectroscopy
Least squares approximations
Marketing
Reflection
Energetic value
Partial-least-squares (PLS)
Root-mean-square error of prediction (RMSEP)
Standard deviation
Fruits
analytical error
article
beverage
calibration
carbohydrate analysis
cluster analysis
data analysis
energy
food analysis
food and drug administration
fruit
infrared spectroscopy
methodology
milk
prediction
priority journal
reflectometry
reproducibility
sampling
standard
validation process
Attenuated Total Reflection
Attenuation
Beverages
Carbohydrates
Fruits
Marketing
Reflection
Determination of the energetic value of fruit and milk-based beverages through partial-least-squares attenuated total reflectance-Fourier transform infrared spectrometry
topic_facet Attenuated total reflectance
Carbohydrates determination
Fruit juice
Hierarchical cluster analysis
Infrared
Milk
Milk shake
Partial-least-squares
Attenuation
Beverages
Carbohydrates
Fourier transform infrared spectroscopy
Least squares approximations
Marketing
Reflection
Energetic value
Partial-least-squares (PLS)
Root-mean-square error of prediction (RMSEP)
Standard deviation
Fruits
analytical error
article
beverage
calibration
carbohydrate analysis
cluster analysis
data analysis
energy
food analysis
food and drug administration
fruit
infrared spectroscopy
methodology
milk
prediction
priority journal
reflectometry
reproducibility
sampling
standard
validation process
Attenuated Total Reflection
Attenuation
Beverages
Carbohydrates
Fruits
Marketing
Reflection
description The estimation of important nutritional parameters, such as carbohydrates content and energetic value (calories) in commercially available fruit juice and flavour milk shakes has been made by attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) using a partial-least-square (PLS) calibration approach. A highly heterogeneous population of 65 samples obtained from the Spanish market, covering fruit juices, flavour milk shakes and milk-added fruit juices was used. The spectral range and the size of the calibration set for building the PLS model have been evaluated. Considering a calibration set comprised of 27 samples, selected via hierarchical cluster analysis, and a validation data set of 38 samples, the absolute mean difference (dx-y) and standard deviation of mean differences (sx-y) of the total carbohydrate content were 0.06 and 0.66 g/100 mL, respectively. The reproducibility of this determination established as the mean standard deviation of each triplicate analysis was 0.05 g/100 mL. In the case of energetic value, the dx-y and sx-y were 2.8 and 18 kJ/100 mL, respectively. The reproducibility of this determination corresponded to a standard deviation of 2.4 kJ/100 mL, for three replicate analyses. The root-mean-square error of prediction (RMSEP) was 18.4 kJ/100 mL and 0.72 g/100 mL for energetic value and total carbohydrates, respectively. The developed methodology favourably compares with that reported in previous works in much restricted sample composition and provided figures of merit which agree with the US-FDA statuary tolerance values. © 2005 Elsevier B.V. All rights reserved.
title Determination of the energetic value of fruit and milk-based beverages through partial-least-squares attenuated total reflectance-Fourier transform infrared spectrometry
title_short Determination of the energetic value of fruit and milk-based beverages through partial-least-squares attenuated total reflectance-Fourier transform infrared spectrometry
title_full Determination of the energetic value of fruit and milk-based beverages through partial-least-squares attenuated total reflectance-Fourier transform infrared spectrometry
title_fullStr Determination of the energetic value of fruit and milk-based beverages through partial-least-squares attenuated total reflectance-Fourier transform infrared spectrometry
title_full_unstemmed Determination of the energetic value of fruit and milk-based beverages through partial-least-squares attenuated total reflectance-Fourier transform infrared spectrometry
title_sort determination of the energetic value of fruit and milk-based beverages through partial-least-squares attenuated total reflectance-fourier transform infrared spectrometry
publishDate 2005
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00032670_v538_n1-2_p181_Moros
http://hdl.handle.net/20.500.12110/paper_00032670_v538_n1-2_p181_Moros
_version_ 1768544204686884864