Dual system increases the resolution of a low coherence interferometer system through a signal detector astigmatic focus
The low coherence interferometry in Fourier space (FD-OCT) is a technique to measure distance with typical values of dynamic range in the order of 3 mm and resolution below 10 microns. In this paper we propose to combine the interferometric technique with a technique that measures distances using...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | Artículo publishedVersion |
Lenguaje: | Inglés |
Publicado: |
2020
|
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12272/4516 |
Aporte de: |
id |
I68-R174-20.500.12272-4516 |
---|---|
record_format |
dspace |
institution |
Universidad Tecnológica Nacional |
institution_str |
I-68 |
repository_str |
R-174 |
collection |
RIA - Repositorio Institucional Abierto (UTN) |
language |
Inglés |
topic |
UTN FRD OCT low coherence interferometry focus signal displacement measurement and tomography |
spellingShingle |
UTN FRD OCT low coherence interferometry focus signal displacement measurement and tomography Morel, Eneas Aguilar, Andres Torga, Jorge Dual system increases the resolution of a low coherence interferometer system through a signal detector astigmatic focus |
topic_facet |
UTN FRD OCT low coherence interferometry focus signal displacement measurement and tomography |
description |
The low coherence interferometry in Fourier space (FD-OCT) is a technique to measure distance with
typical values of dynamic range in the order of 3 mm and resolution below 10 microns. In this paper
we propose to combine the interferometric technique with a technique that measures distances
using astigmatic focus signal, allowing lead the resolution limit of less than 10 nm.
The experimental scheme shown armed with both techniques and experimental results in
displacement of a sample surface, controlled feedback system with a piezoelectric strain gauge which we have used as a reference system.. |
format |
Artículo publishedVersion |
author |
Morel, Eneas Aguilar, Andres Torga, Jorge |
author_facet |
Morel, Eneas Aguilar, Andres Torga, Jorge |
author_sort |
Morel, Eneas |
title |
Dual system increases the resolution of a low coherence interferometer system through a signal detector astigmatic focus |
title_short |
Dual system increases the resolution of a low coherence interferometer system through a signal detector astigmatic focus |
title_full |
Dual system increases the resolution of a low coherence interferometer system through a signal detector astigmatic focus |
title_fullStr |
Dual system increases the resolution of a low coherence interferometer system through a signal detector astigmatic focus |
title_full_unstemmed |
Dual system increases the resolution of a low coherence interferometer system through a signal detector astigmatic focus |
title_sort |
dual system increases the resolution of a low coherence interferometer system through a signal detector astigmatic focus |
publishDate |
2020 |
url |
http://hdl.handle.net/20.500.12272/4516 |
work_keys_str_mv |
AT moreleneas dualsystemincreasestheresolutionofalowcoherenceinterferometersystemthroughasignaldetectorastigmaticfocus AT aguilarandres dualsystemincreasestheresolutionofalowcoherenceinterferometersystemthroughasignaldetectorastigmaticfocus AT torgajorge dualsystemincreasestheresolutionofalowcoherenceinterferometersystemthroughasignaldetectorastigmaticfocus |
bdutipo_str |
Repositorios |
_version_ |
1764820551884341248 |