Relaxation and simplex mathematical algorithms applied to the study of steady-state electrochemical responses of immobilized enzyme biosensors: Comparison with experiments
Fil:Flexer, V. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina.
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | Artículo publishedVersion |
Publicado: |
2008
|
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_15726657_v616_n1-2_p87_Flexer https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=artiaex&d=paper_15726657_v616_n1-2_p87_Flexer_oai |
Aporte de: |
id |
I28-R145-paper_15726657_v616_n1-2_p87_Flexer_oai |
---|---|
record_format |
dspace |
spelling |
I28-R145-paper_15726657_v616_n1-2_p87_Flexer_oai2024-08-16 Flexer, V. Pratt, K.F.E. Garay, F. Bartlett, P.N. Calvo, E.J. 2008 Fil:Flexer, V. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Calvo, E.J. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. application/pdf http://hdl.handle.net/20.500.12110/paper_15726657_v616_n1-2_p87_Flexer info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar J Electroanal Chem 2008;616(1-2):87-98 Electrostatic self-assembly Enzyme electrodes Relaxation method Simplex algorithm Algorithms Electrodes Enzyme electrodes Glucose sensors Linear programming Algorithms Electrochemical electrodes Enzyme immobilization Glucose oxidase Linear programming Relaxation processes Self assembly Comparison with experiments Electrochemical response Electrostatic self assembly Glucose oxidases (GOx) Mathematical algorithms Reaction diffusion problems Relaxation methods Simplex algorithm Enzyme electrodes Enzymes Biosensors Relaxation and simplex mathematical algorithms applied to the study of steady-state electrochemical responses of immobilized enzyme biosensors: Comparison with experiments info:eu-repo/semantics/article info:ar-repo/semantics/artículo info:eu-repo/semantics/publishedVersion https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=artiaex&d=paper_15726657_v616_n1-2_p87_Flexer_oai |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-145 |
collection |
Repositorio Digital de la Universidad de Buenos Aires (UBA) |
topic |
Electrostatic self-assembly Enzyme electrodes Relaxation method Simplex algorithm Algorithms Electrodes Enzyme electrodes Glucose sensors Linear programming Algorithms Electrochemical electrodes Enzyme immobilization Glucose oxidase Linear programming Relaxation processes Self assembly Comparison with experiments Electrochemical response Electrostatic self assembly Glucose oxidases (GOx) Mathematical algorithms Reaction diffusion problems Relaxation methods Simplex algorithm Enzyme electrodes Enzymes Biosensors |
spellingShingle |
Electrostatic self-assembly Enzyme electrodes Relaxation method Simplex algorithm Algorithms Electrodes Enzyme electrodes Glucose sensors Linear programming Algorithms Electrochemical electrodes Enzyme immobilization Glucose oxidase Linear programming Relaxation processes Self assembly Comparison with experiments Electrochemical response Electrostatic self assembly Glucose oxidases (GOx) Mathematical algorithms Reaction diffusion problems Relaxation methods Simplex algorithm Enzyme electrodes Enzymes Biosensors Flexer, V. Pratt, K.F.E. Garay, F. Bartlett, P.N. Calvo, E.J. Relaxation and simplex mathematical algorithms applied to the study of steady-state electrochemical responses of immobilized enzyme biosensors: Comparison with experiments |
topic_facet |
Electrostatic self-assembly Enzyme electrodes Relaxation method Simplex algorithm Algorithms Electrodes Enzyme electrodes Glucose sensors Linear programming Algorithms Electrochemical electrodes Enzyme immobilization Glucose oxidase Linear programming Relaxation processes Self assembly Comparison with experiments Electrochemical response Electrostatic self assembly Glucose oxidases (GOx) Mathematical algorithms Reaction diffusion problems Relaxation methods Simplex algorithm Enzyme electrodes Enzymes Biosensors |
description |
Fil:Flexer, V. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. |
format |
Artículo Artículo publishedVersion |
author |
Flexer, V. Pratt, K.F.E. Garay, F. Bartlett, P.N. Calvo, E.J. |
author_facet |
Flexer, V. Pratt, K.F.E. Garay, F. Bartlett, P.N. Calvo, E.J. |
author_sort |
Flexer, V. |
title |
Relaxation and simplex mathematical algorithms applied to the study of steady-state electrochemical responses of immobilized enzyme biosensors: Comparison with experiments |
title_short |
Relaxation and simplex mathematical algorithms applied to the study of steady-state electrochemical responses of immobilized enzyme biosensors: Comparison with experiments |
title_full |
Relaxation and simplex mathematical algorithms applied to the study of steady-state electrochemical responses of immobilized enzyme biosensors: Comparison with experiments |
title_fullStr |
Relaxation and simplex mathematical algorithms applied to the study of steady-state electrochemical responses of immobilized enzyme biosensors: Comparison with experiments |
title_full_unstemmed |
Relaxation and simplex mathematical algorithms applied to the study of steady-state electrochemical responses of immobilized enzyme biosensors: Comparison with experiments |
title_sort |
relaxation and simplex mathematical algorithms applied to the study of steady-state electrochemical responses of immobilized enzyme biosensors: comparison with experiments |
publishDate |
2008 |
url |
http://hdl.handle.net/20.500.12110/paper_15726657_v616_n1-2_p87_Flexer https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=artiaex&d=paper_15726657_v616_n1-2_p87_Flexer_oai |
work_keys_str_mv |
AT flexerv relaxationandsimplexmathematicalalgorithmsappliedtothestudyofsteadystateelectrochemicalresponsesofimmobilizedenzymebiosensorscomparisonwithexperiments AT prattkfe relaxationandsimplexmathematicalalgorithmsappliedtothestudyofsteadystateelectrochemicalresponsesofimmobilizedenzymebiosensorscomparisonwithexperiments AT garayf relaxationandsimplexmathematicalalgorithmsappliedtothestudyofsteadystateelectrochemicalresponsesofimmobilizedenzymebiosensorscomparisonwithexperiments AT bartlettpn relaxationandsimplexmathematicalalgorithmsappliedtothestudyofsteadystateelectrochemicalresponsesofimmobilizedenzymebiosensorscomparisonwithexperiments AT calvoej relaxationandsimplexmathematicalalgorithmsappliedtothestudyofsteadystateelectrochemicalresponsesofimmobilizedenzymebiosensorscomparisonwithexperiments |
_version_ |
1809357237474295808 |