Optoacoustic Imaging Algorithms: Effect of Piezoelectric Wideband Sensors

Optoacoustic imaging is a hybrid technique with a rapid evolution within the area of biomedical imaging. It combines the rich and versatile optical contrast with the high spatial resolution associated with the low-dispersion ultrasonic wave propagation nature. Its application raises a series of diff...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Massaro Rocca, Patricio, Ciocci Brazzano, Ligia, Acosta, Eduardo Omar, González, Martín Germán
Formato: Artículo publishedVersion
Lenguaje:Español
Publicado: FIUBA 2017
Materias:
Acceso en línea:https://elektron.fi.uba.ar/elektron/article/view/28
https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=elektron&d=28_oai
Aporte de:
id I28-R145-28_oai
record_format dspace
spelling I28-R145-28_oai2026-02-11 Massaro Rocca, Patricio Ciocci Brazzano, Ligia Acosta, Eduardo Omar González, Martín Germán 2017-11-14 Optoacoustic imaging is a hybrid technique with a rapid evolution within the area of biomedical imaging. It combines the rich and versatile optical contrast with the high spatial resolution associated with the low-dispersion ultrasonic wave propagation nature. Its application raises a series of difficult problems that require further developments. One of them, the objective of this work, is to analyze how the optoacoustic image reconstruction algorithms are affected by the use of non-ideal (real) broadband sensors. In particular, as an original contribution, we study the case of integrating ultrasonic sensors based on piezoelectric polymer thin films. In order to achieve this, a temporary back-projection algorithm was implemented for line detectors. Then, using a parametric model for this type of sensors, we studied the influence of the use of a real device on the efficiency of the implemented algorithm. La obtención de imágenes optoacústicas es una técnica híbrida con una rápida evolución dentro del área de imágenes biomédicas. Ésta se beneficia tanto del rico y versátil contraste óptico como de la alta resolución espacial asociada con la naturaleza de baja dispersión de propagación de las ondas ultrasónicas. Su aplicación plantea una serie de difíciles problemas que exigen ulteriores desarrollos. Uno de ellos, el objetivo de este trabajo, es analizar cómo afecta a los algoritmos de reconstrucción de imágenes optoacústicas el uso de sensores no ideales (reales) de banda ancha. En particular, como aporte original, se estudia el caso de los sensores ultrasónicos extensos basados en películas delgadas de polímeros piezoeléctricos. Para lograr esto, se implementó un algoritmo de retroproyección temporal para detectores lineales. Luego, usando un modelo paramétrico para este tipo de sensores, se estudió la influencia del uso de un dispositivo real sobre la eficiencia del susodicho algoritmo. application/pdf text/html https://elektron.fi.uba.ar/elektron/article/view/28 10.37537/rev.elektron.1.2.28.2017 spa FIUBA https://elektron.fi.uba.ar/elektron/article/view/28/29 https://elektron.fi.uba.ar/elektron/article/view/28/162 Derechos de autor 2017 Martin Germán González Elektron Journal; Vol. 1 No. 2 (2017); 58-65 Revista Elektron; Vol. 1 Núm. 2 (2017); 58-65 Revista Elektron; v. 1 n. 2 (2017); 58-65 2525-0159 2525-0159 Optoacoustic Imaging Piezoelectric Sensors Parametric model Imágenes Optoacústicas Sensores Piezoeléctricos Modelo Paramétrico Optoacoustic Imaging Algorithms: Effect of Piezoelectric Wideband Sensors Reconstrucción de Imágenes Optoacústicas: Efecto de los Sensores Piezoeléctricos de Banda Ancha info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=elektron&d=28_oai
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-145
collection Repositorio Digital de la Universidad de Buenos Aires (UBA)
language Español
orig_language_str_mv spa
topic Optoacoustic Imaging
Piezoelectric Sensors
Parametric model
Imágenes Optoacústicas
Sensores Piezoeléctricos
Modelo Paramétrico
spellingShingle Optoacoustic Imaging
Piezoelectric Sensors
Parametric model
Imágenes Optoacústicas
Sensores Piezoeléctricos
Modelo Paramétrico
Massaro Rocca, Patricio
Ciocci Brazzano, Ligia
Acosta, Eduardo Omar
González, Martín Germán
Optoacoustic Imaging Algorithms: Effect of Piezoelectric Wideband Sensors
topic_facet Optoacoustic Imaging
Piezoelectric Sensors
Parametric model
Imágenes Optoacústicas
Sensores Piezoeléctricos
Modelo Paramétrico
description Optoacoustic imaging is a hybrid technique with a rapid evolution within the area of biomedical imaging. It combines the rich and versatile optical contrast with the high spatial resolution associated with the low-dispersion ultrasonic wave propagation nature. Its application raises a series of difficult problems that require further developments. One of them, the objective of this work, is to analyze how the optoacoustic image reconstruction algorithms are affected by the use of non-ideal (real) broadband sensors. In particular, as an original contribution, we study the case of integrating ultrasonic sensors based on piezoelectric polymer thin films. In order to achieve this, a temporary back-projection algorithm was implemented for line detectors. Then, using a parametric model for this type of sensors, we studied the influence of the use of a real device on the efficiency of the implemented algorithm.
format Artículo
publishedVersion
author Massaro Rocca, Patricio
Ciocci Brazzano, Ligia
Acosta, Eduardo Omar
González, Martín Germán
author_facet Massaro Rocca, Patricio
Ciocci Brazzano, Ligia
Acosta, Eduardo Omar
González, Martín Germán
author_sort Massaro Rocca, Patricio
title Optoacoustic Imaging Algorithms: Effect of Piezoelectric Wideband Sensors
title_short Optoacoustic Imaging Algorithms: Effect of Piezoelectric Wideband Sensors
title_full Optoacoustic Imaging Algorithms: Effect of Piezoelectric Wideband Sensors
title_fullStr Optoacoustic Imaging Algorithms: Effect of Piezoelectric Wideband Sensors
title_full_unstemmed Optoacoustic Imaging Algorithms: Effect of Piezoelectric Wideband Sensors
title_sort optoacoustic imaging algorithms: effect of piezoelectric wideband sensors
publisher FIUBA
publishDate 2017
url https://elektron.fi.uba.ar/elektron/article/view/28
https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=elektron&d=28_oai
work_keys_str_mv AT massaroroccapatricio optoacousticimagingalgorithmseffectofpiezoelectricwidebandsensors
AT cioccibrazzanoligia optoacousticimagingalgorithmseffectofpiezoelectricwidebandsensors
AT acostaeduardoomar optoacousticimagingalgorithmseffectofpiezoelectricwidebandsensors
AT gonzalezmartingerman optoacousticimagingalgorithmseffectofpiezoelectricwidebandsensors
AT massaroroccapatricio reconstrucciondeimagenesoptoacusticasefectodelossensorespiezoelectricosdebandaancha
AT cioccibrazzanoligia reconstrucciondeimagenesoptoacusticasefectodelossensorespiezoelectricosdebandaancha
AT acostaeduardoomar reconstrucciondeimagenesoptoacusticasefectodelossensorespiezoelectricosdebandaancha
AT gonzalezmartingerman reconstrucciondeimagenesoptoacusticasefectodelossensorespiezoelectricosdebandaancha
_version_ 1857043032259428352