Determination of ramosetron in rat plasma by LC-ESI-MS and its application
A sensitive and simple liquid chromatography/electrospray mass spectrometry (LC-ESI-MS) method for determination of ramosetron in rat plasma using one-step protein precipitation was developed and validated. After addition of midazolam as internal standard (IS), protein precipitation by acetonitrile...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | Articulo Comunicacion |
Lenguaje: | Inglés |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | http://sedici.unlp.edu.ar/handle/10915/8420 http://www.latamjpharm.org/resumenes/30/10/LAJOP_30_10_2_5.pdf |
Aporte de: |
id |
I19-R120-10915-8420 |
---|---|
record_format |
dspace |
institution |
Universidad Nacional de La Plata |
institution_str |
I-19 |
repository_str |
R-120 |
collection |
SEDICI (UNLP) |
language |
Inglés |
topic |
Farmacia Plasma Cromatografía Liquida Espectrometría de Masas |
spellingShingle |
Farmacia Plasma Cromatografía Liquida Espectrometría de Masas Lin, Guanyang Chen, Xiaole Zheng, Meiqin Wang, Youpei Pang, Lingxia Wang, Qing Determination of ramosetron in rat plasma by LC-ESI-MS and its application |
topic_facet |
Farmacia Plasma Cromatografía Liquida Espectrometría de Masas |
description |
A sensitive and simple liquid chromatography/electrospray mass spectrometry (LC-ESI-MS) method for determination of ramosetron in rat plasma using one-step protein precipitation was developed and validated. After addition of midazolam as internal standard (IS), protein precipitation by acetonitrile was used as sample preparation. Chromatographically separation was achieved on an SB-C18 (2.1 mm × 150 mm, 5 μm) column with acetonitrile-0.1 % formic acid as the mobile phase with gradient elution. Electrospray ionization (ESI) source was applied and operated in positive ion mode; selected ion monitoring (SIM) mode was used to quantification using target fragment ions m/z 280 for ramosetron and m/z 326 for the IS. Calibration plots were linear over the range of 10-1000 ng/mL for ramosetron in rat plasma. Lower limit of quantification (LLOQ) for Ramosetron was 10 ng/mL. Mean recovery of ramosetron from plasma was in the range of 88.5-92.8 %. CV of intra-day and inter-day precision were both less than 15 %. This method is simple and sensitive enough to be used in pharmacokinetic study for determination of ramosetron in rat plasma. |
format |
Articulo Comunicacion |
author |
Lin, Guanyang Chen, Xiaole Zheng, Meiqin Wang, Youpei Pang, Lingxia Wang, Qing |
author_facet |
Lin, Guanyang Chen, Xiaole Zheng, Meiqin Wang, Youpei Pang, Lingxia Wang, Qing |
author_sort |
Lin, Guanyang |
title |
Determination of ramosetron in rat plasma by LC-ESI-MS and its application |
title_short |
Determination of ramosetron in rat plasma by LC-ESI-MS and its application |
title_full |
Determination of ramosetron in rat plasma by LC-ESI-MS and its application |
title_fullStr |
Determination of ramosetron in rat plasma by LC-ESI-MS and its application |
title_full_unstemmed |
Determination of ramosetron in rat plasma by LC-ESI-MS and its application |
title_sort |
determination of ramosetron in rat plasma by lc-esi-ms and its application |
publishDate |
2011 |
url |
http://sedici.unlp.edu.ar/handle/10915/8420 http://www.latamjpharm.org/resumenes/30/10/LAJOP_30_10_2_5.pdf |
work_keys_str_mv |
AT linguanyang determinationoframosetroninratplasmabylcesimsanditsapplication AT chenxiaole determinationoframosetroninratplasmabylcesimsanditsapplication AT zhengmeiqin determinationoframosetroninratplasmabylcesimsanditsapplication AT wangyoupei determinationoframosetroninratplasmabylcesimsanditsapplication AT panglingxia determinationoframosetroninratplasmabylcesimsanditsapplication AT wangqing determinationoframosetroninratplasmabylcesimsanditsapplication |
bdutipo_str |
Repositorios |
_version_ |
1764820488464367620 |