Determination of meropenem in rabbit plasma by LC-MS/MS

A sensitive and selective liquid chromatography tandem mass spectrometry (LC–MS/MS) method for determination of meropenem in rabbit plasma was developed. After addition of triazolam as internal standard (IS), protein precipitation by acetonitrile was used in sample preparation. Chromatographic separ...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Lin, Guanyang, Zhang, Haiyang, Xue, Feng, Li, Wenjuan, Liu, Naihua, Chen, Lianguo, Wang, Xianqin, Xu, Ren-ai, Ma, Jianshe
Formato: Articulo
Lenguaje:Inglés
Publicado: 2011
Materias:
Acceso en línea:http://sedici.unlp.edu.ar/handle/10915/8392
http://www.latamjpharm.org/resumenes/30/10/LAJOP_30_10_1_4.pdf
Aporte de:
id I19-R120-10915-8392
record_format dspace
institution Universidad Nacional de La Plata
institution_str I-19
repository_str R-120
collection SEDICI (UNLP)
language Inglés
topic Farmacia
Farmacocinética
antibiótico
Plasma
Cromatografía Liquida
Espectrometría de Masas
spellingShingle Farmacia
Farmacocinética
antibiótico
Plasma
Cromatografía Liquida
Espectrometría de Masas
Lin, Guanyang
Zhang, Haiyang
Xue, Feng
Li, Wenjuan
Liu, Naihua
Chen, Lianguo
Wang, Xianqin
Xu, Ren-ai
Ma, Jianshe
Determination of meropenem in rabbit plasma by LC-MS/MS
topic_facet Farmacia
Farmacocinética
antibiótico
Plasma
Cromatografía Liquida
Espectrometría de Masas
description A sensitive and selective liquid chromatography tandem mass spectrometry (LC–MS/MS) method for determination of meropenem in rabbit plasma was developed. After addition of triazolam as internal standard (IS), protein precipitation by acetonitrile was used in sample preparation. Chromatographic separation was achieved on a Restek Allure (TM) PFP Propyl (2.1 mm × 100 mm, 5 μm) column with acetonitrile-0.1 % formic acid as mobile phase with gradient elution. Electrospray ionization (ESI) source was applied and operated in positive ion mode; multiple reaction monitoring (MRM) mode was used to quantification using target fragment ions m/z 384.1 → 339.9 for meropenem and m/z 342.7 → 307.8 for the IS. Calibration plots were linear over the range of 0.1-40 μg/mL for meropenem in plasma. Lower limit of quantification (LLOQ) for meropenem was 0.1 μg/mL. Mean recovery of meropenem from plasma was in the range 85.6 %-96.5 %. CV of intra-day and inter-day precision were both less than 15 %. This method is simple and sensitive enough to be used in pharmacokinetic research for determination of meropenem in rabbit plasma.
format Articulo
Articulo
author Lin, Guanyang
Zhang, Haiyang
Xue, Feng
Li, Wenjuan
Liu, Naihua
Chen, Lianguo
Wang, Xianqin
Xu, Ren-ai
Ma, Jianshe
author_facet Lin, Guanyang
Zhang, Haiyang
Xue, Feng
Li, Wenjuan
Liu, Naihua
Chen, Lianguo
Wang, Xianqin
Xu, Ren-ai
Ma, Jianshe
author_sort Lin, Guanyang
title Determination of meropenem in rabbit plasma by LC-MS/MS
title_short Determination of meropenem in rabbit plasma by LC-MS/MS
title_full Determination of meropenem in rabbit plasma by LC-MS/MS
title_fullStr Determination of meropenem in rabbit plasma by LC-MS/MS
title_full_unstemmed Determination of meropenem in rabbit plasma by LC-MS/MS
title_sort determination of meropenem in rabbit plasma by lc-ms/ms
publishDate 2011
url http://sedici.unlp.edu.ar/handle/10915/8392
http://www.latamjpharm.org/resumenes/30/10/LAJOP_30_10_1_4.pdf
work_keys_str_mv AT linguanyang determinationofmeropeneminrabbitplasmabylcmsms
AT zhanghaiyang determinationofmeropeneminrabbitplasmabylcmsms
AT xuefeng determinationofmeropeneminrabbitplasmabylcmsms
AT liwenjuan determinationofmeropeneminrabbitplasmabylcmsms
AT liunaihua determinationofmeropeneminrabbitplasmabylcmsms
AT chenlianguo determinationofmeropeneminrabbitplasmabylcmsms
AT wangxianqin determinationofmeropeneminrabbitplasmabylcmsms
AT xurenai determinationofmeropeneminrabbitplasmabylcmsms
AT majianshe determinationofmeropeneminrabbitplasmabylcmsms
bdutipo_str Repositorios
_version_ 1764820488187543553