Adsorptive voltammetric determination of nimesulide at glassy carbon electrode

A voltammetric method is described for the determination of nimesulide based on the reduction of the nitro group at glassy carbon electrode. The voltammetric behavior of the drug was investigated in Britton-Robinson buffer (pH 2.0-12.0) applying cyclic voltammetry technique. One cathodic and one ano...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Sayed, Gamal O. el-, Yasin, Shalaby A., Ries, Mohammed A. el-, Badawy, Azza A. el-
Formato: Articulo
Lenguaje:Inglés
Publicado: 2009
Materias:
Acceso en línea:http://sedici.unlp.edu.ar/handle/10915/7830
http://www.latamjpharm.org/trabajos/28/5/LAJOP_28_5_1_15_A8974OWUBP.pdf
Aporte de:
id I19-R120-10915-7830
record_format dspace
institution Universidad Nacional de La Plata
institution_str I-19
repository_str R-120
collection SEDICI (UNLP)
language Inglés
topic Farmacia
Farmacología
cyclic voltammetry; glassy carbon electrode; linear sweep; nimesulide; serum
spellingShingle Farmacia
Farmacología
cyclic voltammetry; glassy carbon electrode; linear sweep; nimesulide; serum
Sayed, Gamal O. el-
Yasin, Shalaby A.
Ries, Mohammed A. el-
Badawy, Azza A. el-
Adsorptive voltammetric determination of nimesulide at glassy carbon electrode
topic_facet Farmacia
Farmacología
cyclic voltammetry; glassy carbon electrode; linear sweep; nimesulide; serum
description A voltammetric method is described for the determination of nimesulide based on the reduction of the nitro group at glassy carbon electrode. The voltammetric behavior of the drug was investigated in Britton-Robinson buffer (pH 2.0-12.0) applying cyclic voltammetry technique. One cathodic and one anodic peaks were observed. The comparison of peak heights and potentials indicated that these peaks are quasi-reversible. The determination of nimesulide in pure form was performed using adsorptive linear sweep voltammetry. The cathodic peak current varied linearly in the range 4.0x10<sup>-7</sup> - 5.0x10<sup>-5</sup> M (0.116 - 14.65 μg mL<sup>-1</sup> ). The limits of detection (LOD) and quantification (LOQ) were 3.2x10<sup>-8</sup> and 1.06x10<sup>-7</sup> mol L<sup>-1</sup> , respectively. The proposed method was applied to pharmaceutical formulations with percent recoveries in the range 98.00-101.60%, and a relative standard deviation of 0.61-1.46%. The validity of the method was performed to the determination of nimesulide in human serum with acceptable results for biological samples. No sample pre-treatments or solvent extraction procedures were needed.
format Articulo
Articulo
author Sayed, Gamal O. el-
Yasin, Shalaby A.
Ries, Mohammed A. el-
Badawy, Azza A. el-
author_facet Sayed, Gamal O. el-
Yasin, Shalaby A.
Ries, Mohammed A. el-
Badawy, Azza A. el-
author_sort Sayed, Gamal O. el-
title Adsorptive voltammetric determination of nimesulide at glassy carbon electrode
title_short Adsorptive voltammetric determination of nimesulide at glassy carbon electrode
title_full Adsorptive voltammetric determination of nimesulide at glassy carbon electrode
title_fullStr Adsorptive voltammetric determination of nimesulide at glassy carbon electrode
title_full_unstemmed Adsorptive voltammetric determination of nimesulide at glassy carbon electrode
title_sort adsorptive voltammetric determination of nimesulide at glassy carbon electrode
publishDate 2009
url http://sedici.unlp.edu.ar/handle/10915/7830
http://www.latamjpharm.org/trabajos/28/5/LAJOP_28_5_1_15_A8974OWUBP.pdf
work_keys_str_mv AT sayedgamaloel adsorptivevoltammetricdeterminationofnimesulideatglassycarbonelectrode
AT yasinshalabya adsorptivevoltammetricdeterminationofnimesulideatglassycarbonelectrode
AT riesmohammedael adsorptivevoltammetricdeterminationofnimesulideatglassycarbonelectrode
AT badawyazzaael adsorptivevoltammetricdeterminationofnimesulideatglassycarbonelectrode
bdutipo_str Repositorios
_version_ 1764820485711855616