Determination of puerarin in rat plasma by HPLC with fluorescence detection and its application to pharmacokinetic studies

A simple, rapid, sensitive and selective method of high-performance liquid chromatography with fluorescence detection was developed for determination of puerarin in rat plasma. Chromatography was carried out on a reversed-phase Hypersil ODS column at 30 °C using a mobile phase consisting of methanol...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Luo, Chengfeng, Mu, Yuan, Chen, Minsheng, Liu, Shiming, Zhu, Liu, Liu, Xiawen
Formato: Articulo
Lenguaje:Inglés
Publicado: 2009
Materias:
Acceso en línea:http://sedici.unlp.edu.ar/handle/10915/7769
http://www.latamjpharm.org/trabajos/28/3/LAJOP_28_3_1_5_H6VS6J8WU5.pdf
Aporte de:
id I19-R120-10915-7769
record_format dspace
institution Universidad Nacional de La Plata
institution_str I-19
repository_str R-120
collection SEDICI (UNLP)
language Inglés
topic Farmacia
fluorescence detection; HPLC; rats; pharmacokinetics; puerarin
Cromatografía
Cromatografia líquida de alta eficiencia
Farmacocinética
spellingShingle Farmacia
fluorescence detection; HPLC; rats; pharmacokinetics; puerarin
Cromatografía
Cromatografia líquida de alta eficiencia
Farmacocinética
Luo, Chengfeng
Mu, Yuan
Chen, Minsheng
Liu, Shiming
Zhu, Liu
Liu, Xiawen
Determination of puerarin in rat plasma by HPLC with fluorescence detection and its application to pharmacokinetic studies
topic_facet Farmacia
fluorescence detection; HPLC; rats; pharmacokinetics; puerarin
Cromatografía
Cromatografia líquida de alta eficiencia
Farmacocinética
description A simple, rapid, sensitive and selective method of high-performance liquid chromatography with fluorescence detection was developed for determination of puerarin in rat plasma. Chromatography was carried out on a reversed-phase Hypersil ODS column at 30 °C using a mobile phase consisting of methanol - 50 mM NH4OAc in water (23:77, v/v) with a flow rate of 1 mL/min. The excitation wavelength and emission wavelength were 250nm and 480nm, respectively, PMT-gain was set at 11. The method was demonstrated to be selective and sensitive, and a good linear response was observed over a range of 0.16–120.00 μg/mL in rat plasma. The validated method was successfully applied to the characterization of the pharmacokinetics of puerarin in rat plasma after intravenous administration to rats. The main pharmacokinetic parameters were as follows: AUC<sub>0→t</sub> 41.94 ± 12.90 (mg/L•h), AUC<sub>0→∞</sub> 44.37 ± 28.90 (mg/L•h), MRT 0.97 ± 0.37 (h), T<sub>1/2</sub> 1.06 ± 0.39 (h), Vss 0.09 ± 0.02 (L), Vz 0.14 ± 0.03 (L), Cl 0.10 ± 0.05 (L/h).
format Articulo
Articulo
author Luo, Chengfeng
Mu, Yuan
Chen, Minsheng
Liu, Shiming
Zhu, Liu
Liu, Xiawen
author_facet Luo, Chengfeng
Mu, Yuan
Chen, Minsheng
Liu, Shiming
Zhu, Liu
Liu, Xiawen
author_sort Luo, Chengfeng
title Determination of puerarin in rat plasma by HPLC with fluorescence detection and its application to pharmacokinetic studies
title_short Determination of puerarin in rat plasma by HPLC with fluorescence detection and its application to pharmacokinetic studies
title_full Determination of puerarin in rat plasma by HPLC with fluorescence detection and its application to pharmacokinetic studies
title_fullStr Determination of puerarin in rat plasma by HPLC with fluorescence detection and its application to pharmacokinetic studies
title_full_unstemmed Determination of puerarin in rat plasma by HPLC with fluorescence detection and its application to pharmacokinetic studies
title_sort determination of puerarin in rat plasma by hplc with fluorescence detection and its application to pharmacokinetic studies
publishDate 2009
url http://sedici.unlp.edu.ar/handle/10915/7769
http://www.latamjpharm.org/trabajos/28/3/LAJOP_28_3_1_5_H6VS6J8WU5.pdf
work_keys_str_mv AT luochengfeng determinationofpuerarininratplasmabyhplcwithfluorescencedetectionanditsapplicationtopharmacokineticstudies
AT muyuan determinationofpuerarininratplasmabyhplcwithfluorescencedetectionanditsapplicationtopharmacokineticstudies
AT chenminsheng determinationofpuerarininratplasmabyhplcwithfluorescencedetectionanditsapplicationtopharmacokineticstudies
AT liushiming determinationofpuerarininratplasmabyhplcwithfluorescencedetectionanditsapplicationtopharmacokineticstudies
AT zhuliu determinationofpuerarininratplasmabyhplcwithfluorescencedetectionanditsapplicationtopharmacokineticstudies
AT liuxiawen determinationofpuerarininratplasmabyhplcwithfluorescencedetectionanditsapplicationtopharmacokineticstudies
bdutipo_str Repositorios
_version_ 1764820484973658114