A study of oil-paper insulation voltage dependency during frequency response analysis

People often believe that power factor/dissipation factor testing at power frequency (50/60 Hz) usually exhibits a flat response as a function of test voltage if the insulation is in good condition. Dielectric Frequency Response, DFR is the extension of power factor testing except that the measureme...

Descripción completa

Detalles Bibliográficos
Autores principales: Robalino, Diego M., Cheng, J., Werelius, P., Álvarez, Raúl Emilio
Formato: Objeto de conferencia
Lenguaje:Inglés
Publicado: 2017
Materias:
Acceso en línea:http://sedici.unlp.edu.ar/handle/10915/64665
https://app.box.com/s/erfmszmz0mu1apporeqps793qkgnlkan
Aporte de:
id I19-R120-10915-64665
record_format dspace
institution Universidad Nacional de La Plata
institution_str I-19
repository_str R-120
collection SEDICI (UNLP)
language Inglés
topic Ingeniería
factor de potencia
respuesta dieléctrica
spellingShingle Ingeniería
factor de potencia
respuesta dieléctrica
Robalino, Diego M.
Cheng, J.
Werelius, P.
Álvarez, Raúl Emilio
A study of oil-paper insulation voltage dependency during frequency response analysis
topic_facet Ingeniería
factor de potencia
respuesta dieléctrica
description People often believe that power factor/dissipation factor testing at power frequency (50/60 Hz) usually exhibits a flat response as a function of test voltage if the insulation is in good condition. Dielectric Frequency Response, DFR is the extension of power factor testing except that the measurement is performed from 1 kHz down to typically 1 mHz. It is a very useful tool for evaluating the moisture content in solid insulation of HV and EHV components such as power transformers, bushings, instrument transformers and PILC cables. The voltage dependent phenomenon also called “the Garton effect”, caused by paper absorbing electric charges in oil is investigated. The application of DFR in HV and EHV substations required a conceptual analysis of the phenomenon to better interpret the condition of the insulation system while increasing the signal to noise ratio to minimize the effect of surrounding interference. As a result of this work, authors provide practical recommendations regarding test voltages and frequency ranges to be used under high interference environments. The wide application of the method is supported with experimental field data.
format Objeto de conferencia
Objeto de conferencia
author Robalino, Diego M.
Cheng, J.
Werelius, P.
Álvarez, Raúl Emilio
author_facet Robalino, Diego M.
Cheng, J.
Werelius, P.
Álvarez, Raúl Emilio
author_sort Robalino, Diego M.
title A study of oil-paper insulation voltage dependency during frequency response analysis
title_short A study of oil-paper insulation voltage dependency during frequency response analysis
title_full A study of oil-paper insulation voltage dependency during frequency response analysis
title_fullStr A study of oil-paper insulation voltage dependency during frequency response analysis
title_full_unstemmed A study of oil-paper insulation voltage dependency during frequency response analysis
title_sort study of oil-paper insulation voltage dependency during frequency response analysis
publishDate 2017
url http://sedici.unlp.edu.ar/handle/10915/64665
https://app.box.com/s/erfmszmz0mu1apporeqps793qkgnlkan
work_keys_str_mv AT robalinodiegom astudyofoilpaperinsulationvoltagedependencyduringfrequencyresponseanalysis
AT chengj astudyofoilpaperinsulationvoltagedependencyduringfrequencyresponseanalysis
AT wereliusp astudyofoilpaperinsulationvoltagedependencyduringfrequencyresponseanalysis
AT alvarezraulemilio astudyofoilpaperinsulationvoltagedependencyduringfrequencyresponseanalysis
AT robalinodiegom studyofoilpaperinsulationvoltagedependencyduringfrequencyresponseanalysis
AT chengj studyofoilpaperinsulationvoltagedependencyduringfrequencyresponseanalysis
AT wereliusp studyofoilpaperinsulationvoltagedependencyduringfrequencyresponseanalysis
AT alvarezraulemilio studyofoilpaperinsulationvoltagedependencyduringfrequencyresponseanalysis
bdutipo_str Repositorios
_version_ 1764820479566151680