Hybrid power filter to enhance power quality in a medium-voltage distribution network

This paper deals with the problem of reactive power and harmonics in a standard medium-voltage (MV) distribution network. It proposes a simple and inexpensive solution to enhance power quality when a particular connection to the high-voltage transmission network is required. It presents the design o...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Corasaniti, Víctor Fabián, Barbieri, María Beatriz, Arnera, Patricia Liliana, Valla, María Inés
Formato: Articulo
Lenguaje:Inglés
Publicado: 2009
Materias:
Acceso en línea:http://sedici.unlp.edu.ar/handle/10915/36326
Aporte de:
id I19-R120-10915-36326
record_format dspace
institution Universidad Nacional de La Plata
institution_str I-19
repository_str R-120
collection SEDICI (UNLP)
language Inglés
topic Ingeniería
active filters
Energía Eléctrica
harmonic distortion
power distribution
power quality
reactive power
spellingShingle Ingeniería
active filters
Energía Eléctrica
harmonic distortion
power distribution
power quality
reactive power
Corasaniti, Víctor Fabián
Barbieri, María Beatriz
Arnera, Patricia Liliana
Valla, María Inés
Hybrid power filter to enhance power quality in a medium-voltage distribution network
topic_facet Ingeniería
active filters
Energía Eléctrica
harmonic distortion
power distribution
power quality
reactive power
description This paper deals with the problem of reactive power and harmonics in a standard medium-voltage (MV) distribution network. It proposes a simple and inexpensive solution to enhance power quality when a particular connection to the high-voltage transmission network is required. It presents the design of a hybrid active filter topology connected to the MV level of a power distribution system. Its main task is to regulate a 132-kV voltage level. Reconfiguration of the power delivery network imposes new constraints in a distribution substation so that the reactive compensation should be increased. The topology of a shunt hybrid active filter is analyzed. It is built with the series connection of a passive filter and a low-rated active filter. The proposed filter is directly connected to a 13.8-kV level with no need of a step-down transformer. The possibility of different levels of reactive power compensation is implemented. The proposal shows very good performance for different load demands.
format Articulo
Articulo
author Corasaniti, Víctor Fabián
Barbieri, María Beatriz
Arnera, Patricia Liliana
Valla, María Inés
author_facet Corasaniti, Víctor Fabián
Barbieri, María Beatriz
Arnera, Patricia Liliana
Valla, María Inés
author_sort Corasaniti, Víctor Fabián
title Hybrid power filter to enhance power quality in a medium-voltage distribution network
title_short Hybrid power filter to enhance power quality in a medium-voltage distribution network
title_full Hybrid power filter to enhance power quality in a medium-voltage distribution network
title_fullStr Hybrid power filter to enhance power quality in a medium-voltage distribution network
title_full_unstemmed Hybrid power filter to enhance power quality in a medium-voltage distribution network
title_sort hybrid power filter to enhance power quality in a medium-voltage distribution network
publishDate 2009
url http://sedici.unlp.edu.ar/handle/10915/36326
work_keys_str_mv AT corasanitivictorfabian hybridpowerfiltertoenhancepowerqualityinamediumvoltagedistributionnetwork
AT barbierimariabeatriz hybridpowerfiltertoenhancepowerqualityinamediumvoltagedistributionnetwork
AT arnerapatricialiliana hybridpowerfiltertoenhancepowerqualityinamediumvoltagedistributionnetwork
AT vallamariaines hybridpowerfiltertoenhancepowerqualityinamediumvoltagedistributionnetwork
bdutipo_str Repositorios
_version_ 1764820472631918594