In vitro performance of fluticasone/salmeterol pressurized metered dose inhaler in combination with three different valved holding chambers
Spacer devices are used to optimize airway aerosol deposition from pressurized metered-dose inhalers (pMDI). The in vitro performance of the combination fluticasone/salmeterol pMDI alone and connected to 3 different valved holding chambers (VHC) was compared by measuring impactor entry port (“throat...
Guardado en:
Autores principales: | , , , , , , , |
---|---|
Formato: | Articulo |
Lenguaje: | Inglés |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | http://sedici.unlp.edu.ar/handle/10915/25722 http://www.latamjpharm.org/resumenes/31/6/LAJOP_31_6_1_13.pdf |
Aporte de: |
id |
I19-R120-10915-25722 |
---|---|
record_format |
dspace |
institution |
Universidad Nacional de La Plata |
institution_str |
I-19 |
repository_str |
R-120 |
collection |
SEDICI (UNLP) |
language |
Inglés |
topic |
Farmacia Aerosol Distribution Particle size Fine particle dose Fluticasone and Salmeterol Valved holding chamber |
spellingShingle |
Farmacia Aerosol Distribution Particle size Fine particle dose Fluticasone and Salmeterol Valved holding chamber Gonçalves, Talita M. Rizzo, José Â. Dubus, Jean-Christophe Nicolay, Alain Santana, Davi P. Souza, Pedro H. N. de Figueiroa, José N. Andrieu, Veronique In vitro performance of fluticasone/salmeterol pressurized metered dose inhaler in combination with three different valved holding chambers |
topic_facet |
Farmacia Aerosol Distribution Particle size Fine particle dose Fluticasone and Salmeterol Valved holding chamber |
description |
Spacer devices are used to optimize airway aerosol deposition from pressurized metered-dose inhalers (pMDI). The in vitro performance of the combination fluticasone/salmeterol pMDI alone and connected to 3 different valved holding chambers (VHC) was compared by measuring impactor entry port (“throat”) deposition and fine particle dose (FPD) of each medication. Salmeterol (SX) and Fluticasone (FP) throat deposition was reduced over 90 % by all VHC compared to pMDI alone (p < 0,001). The FPD obtained from pMDI alone and connected to VHCs Vortex®, AeroChamber Plus® and Able Spacer® for Salmeterol (25 μg nominal dose) were 12.2 ± 0.7, 12.5 ± 0.5, 11.6 ± 0.8, and 7.9 ± 0.9 μg, respectively. For Fluticasone (125 μg nominal dose) the FPD were 42.5 ± 2.6, 36.3 ± 3.1, 39.8 ± 2.4, and 22.8 ± 3.5 μg, respectively. There were no statistical differences in FPD between devices, except for AbleSpacer® that delivered a lower FPD for both drugs (p < 0.001). |
format |
Articulo Articulo |
author |
Gonçalves, Talita M. Rizzo, José Â. Dubus, Jean-Christophe Nicolay, Alain Santana, Davi P. Souza, Pedro H. N. de Figueiroa, José N. Andrieu, Veronique |
author_facet |
Gonçalves, Talita M. Rizzo, José Â. Dubus, Jean-Christophe Nicolay, Alain Santana, Davi P. Souza, Pedro H. N. de Figueiroa, José N. Andrieu, Veronique |
author_sort |
Gonçalves, Talita M. |
title |
In vitro performance of fluticasone/salmeterol pressurized metered dose inhaler in combination with three different valved holding chambers |
title_short |
In vitro performance of fluticasone/salmeterol pressurized metered dose inhaler in combination with three different valved holding chambers |
title_full |
In vitro performance of fluticasone/salmeterol pressurized metered dose inhaler in combination with three different valved holding chambers |
title_fullStr |
In vitro performance of fluticasone/salmeterol pressurized metered dose inhaler in combination with three different valved holding chambers |
title_full_unstemmed |
In vitro performance of fluticasone/salmeterol pressurized metered dose inhaler in combination with three different valved holding chambers |
title_sort |
in vitro performance of fluticasone/salmeterol pressurized metered dose inhaler in combination with three different valved holding chambers |
publishDate |
2012 |
url |
http://sedici.unlp.edu.ar/handle/10915/25722 http://www.latamjpharm.org/resumenes/31/6/LAJOP_31_6_1_13.pdf |
work_keys_str_mv |
AT goncalvestalitam invitroperformanceoffluticasonesalmeterolpressurizedmetereddoseinhalerincombinationwiththreedifferentvalvedholdingchambers AT rizzojosea invitroperformanceoffluticasonesalmeterolpressurizedmetereddoseinhalerincombinationwiththreedifferentvalvedholdingchambers AT dubusjeanchristophe invitroperformanceoffluticasonesalmeterolpressurizedmetereddoseinhalerincombinationwiththreedifferentvalvedholdingchambers AT nicolayalain invitroperformanceoffluticasonesalmeterolpressurizedmetereddoseinhalerincombinationwiththreedifferentvalvedholdingchambers AT santanadavip invitroperformanceoffluticasonesalmeterolpressurizedmetereddoseinhalerincombinationwiththreedifferentvalvedholdingchambers AT souzapedrohnde invitroperformanceoffluticasonesalmeterolpressurizedmetereddoseinhalerincombinationwiththreedifferentvalvedholdingchambers AT figueiroajosen invitroperformanceoffluticasonesalmeterolpressurizedmetereddoseinhalerincombinationwiththreedifferentvalvedholdingchambers AT andrieuveronique invitroperformanceoffluticasonesalmeterolpressurizedmetereddoseinhalerincombinationwiththreedifferentvalvedholdingchambers |
bdutipo_str |
Repositorios |
_version_ |
1764820466829099011 |