Validation of microbiological assay for determination of cefuroxime in injectable preparations
The validation of a microbiological assay, applying agar diffusion method for determination of the active of cefuroxime in power for injection, is described. Using a strain of Micrococcus luteus ATCC 9341 as the test organism, cefuroxime was measured in concentrations ranging from 30.0 to 120.0 μg/m...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | Articulo Comunicacion |
Lenguaje: | Inglés |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | http://sedici.unlp.edu.ar/handle/10915/20229 http://www.latamjpharm.org/resumenes/31/5/LAJOP_31_5_2_2.pdf |
Aporte de: |
id |
I19-R120-10915-20229 |
---|---|
record_format |
dspace |
institution |
Universidad Nacional de La Plata |
institution_str |
I-19 |
repository_str |
R-120 |
collection |
SEDICI (UNLP) |
language |
Inglés |
topic |
Farmacia Cefuroxime Cephalosporins Microbiological assay Quality control Validation Cefuroxima Cefalosporinas Control de Calidad |
spellingShingle |
Farmacia Cefuroxime Cephalosporins Microbiological assay Quality control Validation Cefuroxima Cefalosporinas Control de Calidad Vieira, Daniela C.M. Ricarte, Patrícia C. Salgado, Hérida R.N. Validation of microbiological assay for determination of cefuroxime in injectable preparations |
topic_facet |
Farmacia Cefuroxime Cephalosporins Microbiological assay Quality control Validation Cefuroxima Cefalosporinas Control de Calidad |
description |
The validation of a microbiological assay, applying agar diffusion method for determination of the active of cefuroxime in power for injection, is described. Using a strain of Micrococcus luteus ATCC 9341 as the test organism, cefuroxime was measured in concentrations ranging from 30.0 to 120.0 μg/mL.
The method validation showed that it is linear (r = 0.9999), precise (relative standard deviation = 0.37 %) and accurate (it measured the added quantities). Microbiological assay is satisfactory for quantitation of cefuroxime in powder for injection and the validity of the proposed bioassay, which is a simple and a useful alternative methodology for cefuroxime determination in routine quality control. |
format |
Articulo Comunicacion |
author |
Vieira, Daniela C.M. Ricarte, Patrícia C. Salgado, Hérida R.N. |
author_facet |
Vieira, Daniela C.M. Ricarte, Patrícia C. Salgado, Hérida R.N. |
author_sort |
Vieira, Daniela C.M. |
title |
Validation of microbiological assay for determination of cefuroxime in injectable preparations |
title_short |
Validation of microbiological assay for determination of cefuroxime in injectable preparations |
title_full |
Validation of microbiological assay for determination of cefuroxime in injectable preparations |
title_fullStr |
Validation of microbiological assay for determination of cefuroxime in injectable preparations |
title_full_unstemmed |
Validation of microbiological assay for determination of cefuroxime in injectable preparations |
title_sort |
validation of microbiological assay for determination of cefuroxime in injectable preparations |
publishDate |
2012 |
url |
http://sedici.unlp.edu.ar/handle/10915/20229 http://www.latamjpharm.org/resumenes/31/5/LAJOP_31_5_2_2.pdf |
work_keys_str_mv |
AT vieiradanielacm validationofmicrobiologicalassayfordeterminationofcefuroximeininjectablepreparations AT ricartepatriciac validationofmicrobiologicalassayfordeterminationofcefuroximeininjectablepreparations AT salgadoheridarn validationofmicrobiologicalassayfordeterminationofcefuroximeininjectablepreparations |
bdutipo_str |
Repositorios |
_version_ |
1764820465500553220 |