Determination of phillyrin in rat plasma by high performance liquid chromatography–tandem mass spectrometry and its application to a pharmacokinetic study

A simple, fast and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC–MS) method was developed and validated to quantitatively determinate phillyrin in rat plasma using reserpine as internal standard (IS). The sample preparation method was simple only using 0.6 mL aceton...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Cao, Huihui, Zhang, Lei, Peng, Jingdong
Formato: Articulo
Lenguaje:Inglés
Publicado: 2012
Materias:
Acceso en línea:http://sedici.unlp.edu.ar/handle/10915/18081
http://www.latamjpharm.org/resumenes/31/2/LAJOP_31_2_1_5.pdf
Aporte de:
id I19-R120-10915-18081
record_format dspace
institution Universidad Nacional de La Plata
institution_str I-19
repository_str R-120
collection SEDICI (UNLP)
language Inglés
topic Farmacia
HPLC–MS; pharmacokinetic study; phillyrin
Cromatografía Líquida de Alta Presión
Farmacocinética
spellingShingle Farmacia
HPLC–MS; pharmacokinetic study; phillyrin
Cromatografía Líquida de Alta Presión
Farmacocinética
Cao, Huihui
Zhang, Lei
Peng, Jingdong
Determination of phillyrin in rat plasma by high performance liquid chromatography–tandem mass spectrometry and its application to a pharmacokinetic study
topic_facet Farmacia
HPLC–MS; pharmacokinetic study; phillyrin
Cromatografía Líquida de Alta Presión
Farmacocinética
description A simple, fast and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC–MS) method was developed and validated to quantitatively determinate phillyrin in rat plasma using reserpine as internal standard (IS). The sample preparation method was simple only using 0.6 mL acetonitrile as protein precipitant, the supernatant was dried at 50 ºC in a vacuum drying oven and then dissolved in 1.0 mL of organic phase consisted with methanol and acetonitrile (1:9, v/v). The analytical samples were separated on a reversed-phase C18 column (150 × 4.6 mm, 5 μm Phenomenex, CA, USA) at 30 °C, using 0.05 % acetic acid aqueous solution and acetonitrile (56:44, v/v) as mobile phase, at a flow rate of 0.3 mL/min. The detection was performed by electrospray ionization (ESI) mass spectrometry using extracted ion chromatogram (EIC) detection in positive ion mode while monitoring target molecular ions at [M+Na]+ m/z 557.57 for phillyrin and [M+H]+ m/z 609.45 for the I.S. Good linearity was generated over the concentration range of 0.069-8.97 μg/mL (r = 0.9995) with the limit of detection and quantification of 7.04 and 21.12 ng/mL, respectively. Intra-day and inter-day precisions were less than 6 % and the mean recoveries at three tested concentrations ranged from 96.27 to 100.63 %. Those results indicated that the proposed method was fast, sensitive and feasible enough to successfully apply to the pharmacokinetic study in rats after intravenous injection of phillyrin.
format Articulo
Articulo
author Cao, Huihui
Zhang, Lei
Peng, Jingdong
author_facet Cao, Huihui
Zhang, Lei
Peng, Jingdong
author_sort Cao, Huihui
title Determination of phillyrin in rat plasma by high performance liquid chromatography–tandem mass spectrometry and its application to a pharmacokinetic study
title_short Determination of phillyrin in rat plasma by high performance liquid chromatography–tandem mass spectrometry and its application to a pharmacokinetic study
title_full Determination of phillyrin in rat plasma by high performance liquid chromatography–tandem mass spectrometry and its application to a pharmacokinetic study
title_fullStr Determination of phillyrin in rat plasma by high performance liquid chromatography–tandem mass spectrometry and its application to a pharmacokinetic study
title_full_unstemmed Determination of phillyrin in rat plasma by high performance liquid chromatography–tandem mass spectrometry and its application to a pharmacokinetic study
title_sort determination of phillyrin in rat plasma by high performance liquid chromatography–tandem mass spectrometry and its application to a pharmacokinetic study
publishDate 2012
url http://sedici.unlp.edu.ar/handle/10915/18081
http://www.latamjpharm.org/resumenes/31/2/LAJOP_31_2_1_5.pdf
work_keys_str_mv AT caohuihui determinationofphillyrininratplasmabyhighperformanceliquidchromatographytandemmassspectrometryanditsapplicationtoapharmacokineticstudy
AT zhanglei determinationofphillyrininratplasmabyhighperformanceliquidchromatographytandemmassspectrometryanditsapplicationtoapharmacokineticstudy
AT pengjingdong determinationofphillyrininratplasmabyhighperformanceliquidchromatographytandemmassspectrometryanditsapplicationtoapharmacokineticstudy
bdutipo_str Repositorios
_version_ 1764820463777742848