Blasting and Passivation Treatments for ASTM F139 Stainless Steel for Biomedical Applications : Effects on Surface Roughness, Hardening, and Localized Corrosion

Due to the combination of good biofunctionality and biocompatibility at low cost, AISI 316 low carbon vacuum melting (LVM) stainless steel, as considered in ASTM F139 standard, is often the first choice for medical implants, particularly for use in orthopedic surgery. Proper surface finish must be p...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Lemos Barboza, Adriana Lucila, Kang, Kyung Won, Bonetto, Rita Dominga, Llorente, Carlos Luis, Bilmes, Pablo David, Gervasi, Claudio Alfredo
Formato: Articulo
Lenguaje:Inglés
Publicado: 2014
Materias:
Acceso en línea:http://sedici.unlp.edu.ar/handle/10915/132888
Aporte de:
id I19-R120-10915-132888
record_format dspace
institution Universidad Nacional de La Plata
institution_str I-19
repository_str R-120
collection SEDICI (UNLP)
language Inglés
topic Ingeniería
316 LVM stainless steel
corrosion
glass bead blasting
hardness
nitric acid passivation
roughness parameters
Metalurgia
spellingShingle Ingeniería
316 LVM stainless steel
corrosion
glass bead blasting
hardness
nitric acid passivation
roughness parameters
Metalurgia
Lemos Barboza, Adriana Lucila
Kang, Kyung Won
Bonetto, Rita Dominga
Llorente, Carlos Luis
Bilmes, Pablo David
Gervasi, Claudio Alfredo
Blasting and Passivation Treatments for ASTM F139 Stainless Steel for Biomedical Applications : Effects on Surface Roughness, Hardening, and Localized Corrosion
topic_facet Ingeniería
316 LVM stainless steel
corrosion
glass bead blasting
hardness
nitric acid passivation
roughness parameters
Metalurgia
description Due to the combination of good biofunctionality and biocompatibility at low cost, AISI 316 low carbon vacuum melting (LVM) stainless steel, as considered in ASTM F139 standard, is often the first choice for medical implants, particularly for use in orthopedic surgery. Proper surface finish must be provided to ensure adequate interactions of the alloy with human body tissues that in turn allows the material to deliver the desired performance. Preliminary studies performed in our laboratory on AISI 316LVM stainless steel surfaces modified by glass bead blasting (from industrial supplier) followed by different nitric acid passivation conditions disclosed the necessity to extend parameters of the surface treatments and to further consider roughness, pitting corrosion resistance, and surface and subsurface hardening measurements, all in one, as the most effective characterization strategy. This was the approach adopted in the present work. Roughness assessment was performed by means of amplitude parameters, functional parameters, and an estimator of the fractal dimension that characterizes surface topography. We clearly demonstrate that the blasting treatment should be carried out under controlled conditions in order to obtain similar surface and subsurface properties. Otherwise, a variation in one of the parameters could modify the surface properties, exerting a profound impact on its application as biomaterial. A passivation step is necessary to offset the detrimental effect of blasting on pitting corrosion resistance.
format Articulo
Articulo
author Lemos Barboza, Adriana Lucila
Kang, Kyung Won
Bonetto, Rita Dominga
Llorente, Carlos Luis
Bilmes, Pablo David
Gervasi, Claudio Alfredo
author_facet Lemos Barboza, Adriana Lucila
Kang, Kyung Won
Bonetto, Rita Dominga
Llorente, Carlos Luis
Bilmes, Pablo David
Gervasi, Claudio Alfredo
author_sort Lemos Barboza, Adriana Lucila
title Blasting and Passivation Treatments for ASTM F139 Stainless Steel for Biomedical Applications : Effects on Surface Roughness, Hardening, and Localized Corrosion
title_short Blasting and Passivation Treatments for ASTM F139 Stainless Steel for Biomedical Applications : Effects on Surface Roughness, Hardening, and Localized Corrosion
title_full Blasting and Passivation Treatments for ASTM F139 Stainless Steel for Biomedical Applications : Effects on Surface Roughness, Hardening, and Localized Corrosion
title_fullStr Blasting and Passivation Treatments for ASTM F139 Stainless Steel for Biomedical Applications : Effects on Surface Roughness, Hardening, and Localized Corrosion
title_full_unstemmed Blasting and Passivation Treatments for ASTM F139 Stainless Steel for Biomedical Applications : Effects on Surface Roughness, Hardening, and Localized Corrosion
title_sort blasting and passivation treatments for astm f139 stainless steel for biomedical applications : effects on surface roughness, hardening, and localized corrosion
publishDate 2014
url http://sedici.unlp.edu.ar/handle/10915/132888
work_keys_str_mv AT lemosbarbozaadrianalucila blastingandpassivationtreatmentsforastmf139stainlesssteelforbiomedicalapplicationseffectsonsurfaceroughnesshardeningandlocalizedcorrosion
AT kangkyungwon blastingandpassivationtreatmentsforastmf139stainlesssteelforbiomedicalapplicationseffectsonsurfaceroughnesshardeningandlocalizedcorrosion
AT bonettoritadominga blastingandpassivationtreatmentsforastmf139stainlesssteelforbiomedicalapplicationseffectsonsurfaceroughnesshardeningandlocalizedcorrosion
AT llorentecarlosluis blastingandpassivationtreatmentsforastmf139stainlesssteelforbiomedicalapplicationseffectsonsurfaceroughnesshardeningandlocalizedcorrosion
AT bilmespablodavid blastingandpassivationtreatmentsforastmf139stainlesssteelforbiomedicalapplicationseffectsonsurfaceroughnesshardeningandlocalizedcorrosion
AT gervasiclaudioalfredo blastingandpassivationtreatmentsforastmf139stainlesssteelforbiomedicalapplicationseffectsonsurfaceroughnesshardeningandlocalizedcorrosion
bdutipo_str Repositorios
_version_ 1764820454450659329