Trivalent chromium conversion layer: a way of enchancing the electrogalvanized steel corrosion protection
Conversion coatings are used on galvanized steels to provide corrosion protection and for special applications are covered with an additional organic or inorganic topcoat. Hexavalent chromium-based passivation treatments have been successfully used as conversion coatings; however, as it is heavily t...
Guardado en:
| Autores principales: | , , , , |
|---|---|
| Formato: | Objeto de conferencia Resumen |
| Lenguaje: | Inglés |
| Publicado: |
2010
|
| Materias: | |
| Acceso en línea: | http://sedici.unlp.edu.ar/handle/10915/119099 |
| Aporte de: |
| id |
I19-R120-10915-119099 |
|---|---|
| record_format |
dspace |
| institution |
Universidad Nacional de La Plata |
| institution_str |
I-19 |
| repository_str |
R-120 |
| collection |
SEDICI (UNLP) |
| language |
Inglés |
| topic |
Química Trivalent chromium Hexavalent chromium Electrogalvanized steel Conversion treatment |
| spellingShingle |
Química Trivalent chromium Hexavalent chromium Electrogalvanized steel Conversion treatment Tomachuk, C. Elsner, Cecilia Inés Di Sarli, Alejandro Ramón Culcasi, José Daniel Costa, I. Trivalent chromium conversion layer: a way of enchancing the electrogalvanized steel corrosion protection |
| topic_facet |
Química Trivalent chromium Hexavalent chromium Electrogalvanized steel Conversion treatment |
| description |
Conversion coatings are used on galvanized steels to provide corrosion protection and for special applications are covered with an additional organic or inorganic topcoat. Hexavalent chromium-based passivation treatments have been successfully used as conversion coatings; however, as it is heavily toxic and carcinogenic, national and international environmental regulations impose its removal. From encouraging research works, less toxic alternative coatings have been recently proposed. Among promising alternatives, the environmentally friendly trivalent chromium-based conversion coating is one of the most studied. It decreases health hazards from airborne chromium and reduces the costs of waste treatment and final disposal, as the process needs low metal concentration and does not use hexavalent chromium or additives with strong oxidants. The present work aims to evaluate the corrosion behavior of electrogalvanized steel panels passivated with a trivalent chromium-based layer in 0.5 M NaCl solution. For this, electrochemical impedance spectroscopy (EIS) and morphological observations (SEM/EDAX and XPS) were carried out. The conversion treatments studied were based on: (i) Cr3+ (ZBLU); (ii) Cr3+ and Co ions (ZGREEN); and (iii) Cr3+, fluorzirconate ions and SiO2 (ZCOAT). An hexavalent chromium passivation layer (ZHEX) obtained under the same conditions adopted for the other treatments was used as reference. The results suggest that the corrosion protection supplied by ZCOAT is similar to the ZHEX, and it was followed by ZGREEN and ZBLU, respectively. Therefore, ZCOAT is a promising alternative to the traditional chromated coating. |
| format |
Objeto de conferencia Resumen |
| author |
Tomachuk, C. Elsner, Cecilia Inés Di Sarli, Alejandro Ramón Culcasi, José Daniel Costa, I. |
| author_facet |
Tomachuk, C. Elsner, Cecilia Inés Di Sarli, Alejandro Ramón Culcasi, José Daniel Costa, I. |
| author_sort |
Tomachuk, C. |
| title |
Trivalent chromium conversion layer: a way of enchancing the electrogalvanized steel corrosion protection |
| title_short |
Trivalent chromium conversion layer: a way of enchancing the electrogalvanized steel corrosion protection |
| title_full |
Trivalent chromium conversion layer: a way of enchancing the electrogalvanized steel corrosion protection |
| title_fullStr |
Trivalent chromium conversion layer: a way of enchancing the electrogalvanized steel corrosion protection |
| title_full_unstemmed |
Trivalent chromium conversion layer: a way of enchancing the electrogalvanized steel corrosion protection |
| title_sort |
trivalent chromium conversion layer: a way of enchancing the electrogalvanized steel corrosion protection |
| publishDate |
2010 |
| url |
http://sedici.unlp.edu.ar/handle/10915/119099 |
| work_keys_str_mv |
AT tomachukc trivalentchromiumconversionlayerawayofenchancingtheelectrogalvanizedsteelcorrosionprotection AT elsnerceciliaines trivalentchromiumconversionlayerawayofenchancingtheelectrogalvanizedsteelcorrosionprotection AT disarlialejandroramon trivalentchromiumconversionlayerawayofenchancingtheelectrogalvanizedsteelcorrosionprotection AT culcasijosedaniel trivalentchromiumconversionlayerawayofenchancingtheelectrogalvanizedsteelcorrosionprotection AT costai trivalentchromiumconversionlayerawayofenchancingtheelectrogalvanizedsteelcorrosionprotection |
| bdutipo_str |
Repositorios |
| _version_ |
1764820447915933696 |