Implementación del algoritmo reverso para el cribado de sífilis en un laboratorio clínico
Background: Syphilis remains a public health concern worldwide, the accuracy of diagnostic tests is critical for its successful control. Currently, there are two approaches to the diagnosis of syphilis using serological tests: the traditional algorithm and the reverse algorithm. Aim: The goal of th...
Guardado en:
| Autores principales: | , , , , , |
|---|---|
| Formato: | Articulo |
| Lenguaje: | Español |
| Publicado: |
2019
|
| Materias: | |
| Acceso en línea: | http://sedici.unlp.edu.ar/handle/10915/109201 |
| Aporte de: |
| id |
I19-R120-10915-109201 |
|---|---|
| record_format |
dspace |
| institution |
Universidad Nacional de La Plata |
| institution_str |
I-19 |
| repository_str |
R-120 |
| collection |
SEDICI (UNLP) |
| language |
Español |
| topic |
Bioquímica Syphilis Reverse algorithm for syphilis Treponemal chemiluminescence immunoassay Sífilis Algoritmo reverso para sífilis Inmunoensayo treponémico quimioluminiscente |
| spellingShingle |
Bioquímica Syphilis Reverse algorithm for syphilis Treponemal chemiluminescence immunoassay Sífilis Algoritmo reverso para sífilis Inmunoensayo treponémico quimioluminiscente Martínez Methol, María Soledad Ventimiglia, Fernando Daniel Aristimuño, Ana M. Colina, Amelia N. de la Bruno, Jorge J. D’Agostino, Liliana E. Implementación del algoritmo reverso para el cribado de sífilis en un laboratorio clínico |
| topic_facet |
Bioquímica Syphilis Reverse algorithm for syphilis Treponemal chemiluminescence immunoassay Sífilis Algoritmo reverso para sífilis Inmunoensayo treponémico quimioluminiscente |
| description |
Background: Syphilis remains a public health concern worldwide, the accuracy of diagnostic tests is critical for its successful control. Currently, there are two approaches to the diagnosis of syphilis using serological tests:
the traditional algorithm and the reverse algorithm. Aim: The goal of this study was to analyse the advantages and disadvantages in the implementation of the syphilis reverse-screening algorithm in an outpatient clinical laboratory.
Methods: An observational cross-sectional study was carried out analyzing 246 reactive sera from a total of 14700 requests for syphilis serology. Chemiluminescent assay ARCHITECT Syphilis TP, V.D.R.L. and FTA-Abs were performed. Results: Among 246 reactive sera by ARCHITECT Syphilis TP, 129 were reactive and 117 were non-reactive by V.D.R.L. the last mentioned resulted in 97 reactive and 20 non-reactive by FTA-Abs, suggesting false positives (0.13%).Two patients with primary infection were detected, that were not detected by V.D.R.L. and one pregnant woman with primary infection with a high value S/CO and V.D.R.L.:1 dils. Conclusions: Among the advantages of using a reverse algorithm were greater sensitivity in the detection of patients with primary syphilis; automation, complete traceability of the samples; objective interpretation and conclusive results. |
| format |
Articulo Articulo |
| author |
Martínez Methol, María Soledad Ventimiglia, Fernando Daniel Aristimuño, Ana M. Colina, Amelia N. de la Bruno, Jorge J. D’Agostino, Liliana E. |
| author_facet |
Martínez Methol, María Soledad Ventimiglia, Fernando Daniel Aristimuño, Ana M. Colina, Amelia N. de la Bruno, Jorge J. D’Agostino, Liliana E. |
| author_sort |
Martínez Methol, María Soledad |
| title |
Implementación del algoritmo reverso para el cribado de sífilis en un laboratorio clínico |
| title_short |
Implementación del algoritmo reverso para el cribado de sífilis en un laboratorio clínico |
| title_full |
Implementación del algoritmo reverso para el cribado de sífilis en un laboratorio clínico |
| title_fullStr |
Implementación del algoritmo reverso para el cribado de sífilis en un laboratorio clínico |
| title_full_unstemmed |
Implementación del algoritmo reverso para el cribado de sífilis en un laboratorio clínico |
| title_sort |
implementación del algoritmo reverso para el cribado de sífilis en un laboratorio clínico |
| publishDate |
2019 |
| url |
http://sedici.unlp.edu.ar/handle/10915/109201 |
| work_keys_str_mv |
AT martinezmetholmariasoledad implementaciondelalgoritmoreversoparaelcribadodesifilisenunlaboratorioclinico AT ventimigliafernandodaniel implementaciondelalgoritmoreversoparaelcribadodesifilisenunlaboratorioclinico AT aristimunoanam implementaciondelalgoritmoreversoparaelcribadodesifilisenunlaboratorioclinico AT colinaameliandela implementaciondelalgoritmoreversoparaelcribadodesifilisenunlaboratorioclinico AT brunojorgej implementaciondelalgoritmoreversoparaelcribadodesifilisenunlaboratorioclinico AT dagostinolilianae implementaciondelalgoritmoreversoparaelcribadodesifilisenunlaboratorioclinico AT martinezmetholmariasoledad implementationofthereversescreeningsyphilisalgorithminaclinicallaboratory AT ventimigliafernandodaniel implementationofthereversescreeningsyphilisalgorithminaclinicallaboratory AT aristimunoanam implementationofthereversescreeningsyphilisalgorithminaclinicallaboratory AT colinaameliandela implementationofthereversescreeningsyphilisalgorithminaclinicallaboratory AT brunojorgej implementationofthereversescreeningsyphilisalgorithminaclinicallaboratory AT dagostinolilianae implementationofthereversescreeningsyphilisalgorithminaclinicallaboratory |
| bdutipo_str |
Repositorios |
| _version_ |
1764820443597897729 |