A simple and reproducible capacitive electrode
Capacitive Electrodes (CE) allow the acquisition of biopotentials through a dielectric layer, without the use of electrolytes, just by placing them on skin or clothing, but demands front-ends with ultra-high input impedances. This must be achieved while providing a path for bias currents, calling fo...
Guardado en:
| Autores principales: | , , , |
|---|---|
| Formato: | Articulo |
| Lenguaje: | Inglés |
| Publicado: |
2016
|
| Materias: | |
| Acceso en línea: | http://sedici.unlp.edu.ar/handle/10915/105075 https://www.sciencedirect.com/science/article/abs/pii/S1350453315002854 |
| Aporte de: |
| id |
I19-R120-10915-105075 |
|---|---|
| record_format |
dspace |
| institution |
Universidad Nacional de La Plata |
| institution_str |
I-19 |
| repository_str |
R-120 |
| collection |
SEDICI (UNLP) |
| language |
Inglés |
| topic |
Ingeniería Electrotecnia insulating electrodes active electrodes non-contact measurements |
| spellingShingle |
Ingeniería Electrotecnia insulating electrodes active electrodes non-contact measurements Spinelli, Enrique Mario Guerrero, Federico Nicolás García, Pablo Andrés Haberman, Marcelo Alejandro A simple and reproducible capacitive electrode |
| topic_facet |
Ingeniería Electrotecnia insulating electrodes active electrodes non-contact measurements |
| description |
Capacitive Electrodes (CE) allow the acquisition of biopotentials through a dielectric layer, without the use of electrolytes, just by placing them on skin or clothing, but demands front-ends with ultra-high input impedances. This must be achieved while providing a path for bias currents, calling for ultra-high value resistors and special components and construction techniques. A simple CE that uses bootstrap techniques to avoid ultra-high value components and special materials is proposed. When electrodes are placed on the skin; that is, with coupling capacitances C<sub>S</sub> of around 100 pF, they present a noise level of 3.3 μV<sub>RMS</sub> in a 0.5-100 Hz bandwidth, which is appropriate for electrocardiography (ECG) measurements. Construction details of the CE and the complete circuit, including a fast recovery feature, are presented. |
| format |
Articulo Articulo |
| author |
Spinelli, Enrique Mario Guerrero, Federico Nicolás García, Pablo Andrés Haberman, Marcelo Alejandro |
| author_facet |
Spinelli, Enrique Mario Guerrero, Federico Nicolás García, Pablo Andrés Haberman, Marcelo Alejandro |
| author_sort |
Spinelli, Enrique Mario |
| title |
A simple and reproducible capacitive electrode |
| title_short |
A simple and reproducible capacitive electrode |
| title_full |
A simple and reproducible capacitive electrode |
| title_fullStr |
A simple and reproducible capacitive electrode |
| title_full_unstemmed |
A simple and reproducible capacitive electrode |
| title_sort |
simple and reproducible capacitive electrode |
| publishDate |
2016 |
| url |
http://sedici.unlp.edu.ar/handle/10915/105075 https://www.sciencedirect.com/science/article/abs/pii/S1350453315002854 |
| work_keys_str_mv |
AT spinellienriquemario asimpleandreproduciblecapacitiveelectrode AT guerrerofedericonicolas asimpleandreproduciblecapacitiveelectrode AT garciapabloandres asimpleandreproduciblecapacitiveelectrode AT habermanmarceloalejandro asimpleandreproduciblecapacitiveelectrode AT spinellienriquemario simpleandreproduciblecapacitiveelectrode AT guerrerofedericonicolas simpleandreproduciblecapacitiveelectrode AT garciapabloandres simpleandreproduciblecapacitiveelectrode AT habermanmarceloalejandro simpleandreproduciblecapacitiveelectrode |
| bdutipo_str |
Repositorios |
| _version_ |
1764820442824048643 |