Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 1016.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m2-modules, each segmented into 64 scintillators coupled to silicon photomult...

Descripción completa

Detalles Bibliográficos
Autores principales: The Pierre Auger collaboration, Freire, M. M., Micheletti, M. I.
Formato: article artículo publishedVersion
Lenguaje:Inglés
Publicado: IOP Publishing 2022
Materias:
Acceso en línea:http://hdl.handle.net/2133/23409
http://hdl.handle.net/2133/23409
Aporte de:
id I15-R121-2133-23409
record_format dspace
institution Universidad Nacional de Rosario
institution_str I-15
repository_str R-121
collection Repositorio Hipermedial de la Universidad Nacional de Rosario (UNR)
language Inglés
orig_language_str_mv eng
topic Particle detectors
Detector alignment and calibration methods
Photon detectors for uvL
Performance of high energy physics detectors
Visible and ir photons
spellingShingle Particle detectors
Detector alignment and calibration methods
Photon detectors for uvL
Performance of high energy physics detectors
Visible and ir photons
The Pierre Auger collaboration
Freire, M. M.
Micheletti, M. I.
Calibration of the underground muon detector of the Pierre Auger Observatory
topic_facet Particle detectors
Detector alignment and calibration methods
Photon detectors for uvL
Performance of high energy physics detectors
Visible and ir photons
description To obtain direct measurements of the muon content of extensive air showers with energy above 1016.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m2-modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m2 close to the intersection of the shower axis with the ground to much less than one per m2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.
format article
artículo
publishedVersion
author The Pierre Auger collaboration
Freire, M. M.
Micheletti, M. I.
author_facet The Pierre Auger collaboration
Freire, M. M.
Micheletti, M. I.
author_sort The Pierre Auger collaboration
title Calibration of the underground muon detector of the Pierre Auger Observatory
title_short Calibration of the underground muon detector of the Pierre Auger Observatory
title_full Calibration of the underground muon detector of the Pierre Auger Observatory
title_fullStr Calibration of the underground muon detector of the Pierre Auger Observatory
title_full_unstemmed Calibration of the underground muon detector of the Pierre Auger Observatory
title_sort calibration of the underground muon detector of the pierre auger observatory
publisher IOP Publishing
publishDate 2022
url http://hdl.handle.net/2133/23409
http://hdl.handle.net/2133/23409
work_keys_str_mv AT thepierreaugercollaboration calibrationoftheundergroundmuondetectorofthepierreaugerobservatory
AT freiremm calibrationoftheundergroundmuondetectorofthepierreaugerobservatory
AT michelettimi calibrationoftheundergroundmuondetectorofthepierreaugerobservatory
bdutipo_str Repositorios
_version_ 1764820412097626114