Calibration of the underground muon detector of the Pierre Auger Observatory
To obtain direct measurements of the muon content of extensive air showers with energy above 1016.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m2-modules, each segmented into 64 scintillators coupled to silicon photomult...
Autores principales: | , , |
---|---|
Formato: | article artículo publishedVersion |
Lenguaje: | Inglés |
Publicado: |
IOP Publishing
2022
|
Materias: | |
Acceso en línea: | http://hdl.handle.net/2133/23409 http://hdl.handle.net/2133/23409 |
Aporte de: |
id |
I15-R121-2133-23409 |
---|---|
record_format |
dspace |
institution |
Universidad Nacional de Rosario |
institution_str |
I-15 |
repository_str |
R-121 |
collection |
Repositorio Hipermedial de la Universidad Nacional de Rosario (UNR) |
language |
Inglés |
orig_language_str_mv |
eng |
topic |
Particle detectors Detector alignment and calibration methods Photon detectors for uvL Performance of high energy physics detectors Visible and ir photons |
spellingShingle |
Particle detectors Detector alignment and calibration methods Photon detectors for uvL Performance of high energy physics detectors Visible and ir photons The Pierre Auger collaboration Freire, M. M. Micheletti, M. I. Calibration of the underground muon detector of the Pierre Auger Observatory |
topic_facet |
Particle detectors Detector alignment and calibration methods Photon detectors for uvL Performance of high energy physics detectors Visible and ir photons |
description |
To obtain direct measurements of the muon content of extensive air showers with energy above 1016.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m2-modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m2 close to the intersection of the shower axis with the ground to much less than one per m2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years. |
format |
article artículo publishedVersion |
author |
The Pierre Auger collaboration Freire, M. M. Micheletti, M. I. |
author_facet |
The Pierre Auger collaboration Freire, M. M. Micheletti, M. I. |
author_sort |
The Pierre Auger collaboration |
title |
Calibration of the underground muon detector of the Pierre Auger Observatory |
title_short |
Calibration of the underground muon detector of the Pierre Auger Observatory |
title_full |
Calibration of the underground muon detector of the Pierre Auger Observatory |
title_fullStr |
Calibration of the underground muon detector of the Pierre Auger Observatory |
title_full_unstemmed |
Calibration of the underground muon detector of the Pierre Auger Observatory |
title_sort |
calibration of the underground muon detector of the pierre auger observatory |
publisher |
IOP Publishing |
publishDate |
2022 |
url |
http://hdl.handle.net/2133/23409 http://hdl.handle.net/2133/23409 |
work_keys_str_mv |
AT thepierreaugercollaboration calibrationoftheundergroundmuondetectorofthepierreaugerobservatory AT freiremm calibrationoftheundergroundmuondetectorofthepierreaugerobservatory AT michelettimi calibrationoftheundergroundmuondetectorofthepierreaugerobservatory |
bdutipo_str |
Repositorios |
_version_ |
1764820412097626114 |