Characterization of the mechanic behavior of the conduits used in the confection of vascular accesses in dialyzed subjects

Intimal hyperplasia development is recognized as the most important cause of vascular access failure in patients submitted renal function replacement therapy. An important factor that affects the development of intimal hyperplasia is elastic mismatch between native vessel and among vein, arteries an...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Zócalo, Y.
Otros Autores: Pérez Campos, H., Galli, C.N, Saldías, M., Camus, J.M, Silva, W., Bia Santana, D., Álvarez, O., Álvarez, I., Armentano, R.
Formato: Capítulo de libro
Lenguaje:Español
Publicado: 2005
Materias:
Acceso en línea:Registro en Scopus
Handle
Registro en la Biblioteca Digital
Aporte de:Registro referencial: Solicitar el recurso aquí
LEADER 10928caa a22010457a 4500
001 PAPER-3826
003 AR-BaUEN
005 20230518203318.0
008 140217s2005 xx ||||fo|||| 00| 0 spa|d
024 7 |2 scopus  |a 2-s2.0-32044471046 
024 7 |2 cas  |a politef, 9002-84-0, 9039-02-5 
040 |a Scopus  |b spa  |c AR-BaUEN  |d AR-BaUEN 
100 1 |a Zócalo, Y. 
245 1 0 |a Characterization of the mechanic behavior of the conduits used in the confection of vascular accesses in dialyzed subjects 
260 |c 2005 
270 1 0 |m Galli, C.N.; Departamento de Ingeniería Cardiovascular, Universidad Tecnológica Nacional, FRBA, Medrano 951, Buenos Aires, Argentina; email: cngalli@secyt.frba.utn.edu.ar 
506 |2 openaire  |e Política editorial 
504 |a Canaud, B., Venous Accesses for Hemodialysis-Facts and Througts (2004) Business Brieffing: Global Healthcare-Advanced Medical Technologies, pp. 1-5 
504 |a Grigioni, M., Jaffrin, M., Rieu, R., Verdonck, P., (1994) Chapter 6: Artificial Organs. En Cardiovascular Fluid Dynamics Principles and Clinical Applications, pp. 1-22. , Second Ed. France 
504 |a Rodriguez, J.A., Amadans, L., Ferrer, E., Olmos, A., Codina, S., Bartolomé, J., Borrellas, J., Piera, L., The function of permanent vascular access (2000) Nephrol Dial Transplant, 15, pp. 402-408 
504 |a Young, E.W., Dykstra, D.M., Goodkin, D.A., Mapes, D.L., Wolfe, R.A., Held, P.J., Hemodialysis vascular access preferences and outcomes in the Dialyisis Outcomes and Practice Patterns Study (DOPPS) (2002) Kidney International, 61, pp. 2266-2271 
504 |a Mastsuda, H., Miyazaki, M., Oka, Y., Nakao, A., Choda, Y., Kokumai, Y., Kunitomo, K., Tanaka, N., A Polyurethane Vascular Access Graft and Hybrid Polytetrafluoroethylene Graft as an Arteriovenous Fistula for Hemodialysis: Comparison with an Expanded Polytetrafluoroethylene Graft (2003) Artificial Organs, 27 (8), pp. 722-727 
504 |a Tsui, J.C.S., Dashwood, M.R., Recent strategies to reduce vein graft occlusion: A need to limit the effect of vascular damage (2002) Eur J Vasc Endovasc Surg, 23, pp. 202-208 
504 |a Bolton, W., Cull, D., Taylor, S., Carsten, C., Snyder, B., Sullivan, T., Yourkey, J., Gray, B., The use of Cryopreserved femoral vein grafts for hemodialysis access in patients at high risk for infection: A word of caution (2002) J Vasc Surg, 36, pp. 464-468 
504 |a Cabrera-Fischer, E.I., Bia Santana, D., Cassanello, G.L., Zócalo, Y., Craword, E.V., Casas, R., Armentano, R.L., Reduced elastic mismatch achieved by interposing vein cuff in expanded polytetrafluoroethylene femoral bypass decreases intimal hyperplasia (2005) Artificial Organs, 29 (2), pp. 122-130 
504 |a Blacher, J., Guerin, A., Pannier, B., Marchais, S., London, G., Arterial calcifications, arterial stiffness, and cardiovascular risk in end-stage renal disease (2001) Hypertension, 38, pp. 938-942 
504 |a Galli, C., Risk, M., Camus, J., Cabrera Fischer, E., Calcificación arterial y su evaluación funcional en la enfermedad renal crónica (2004) Rev Nefrol Dial Y Transpl, 24 (4), pp. 165-170 
504 |a Galli, C., Camus, J., Cabrera Fischer, E., Risk, M., La velocidad de la onda del pulso en la evaluación vascular de pacientes con insuficiencia renal (2004) Rev Fed Arg Cardiol, 33, pp. 212-217 
504 |a Bia, D., Armentano, R.L., Zócalo, Y., Barmak, W., Migliaron, E., Cabrera Fischer, E.I., In vitro model to study arterial wall dynamics through pressure-diameter relationship analysis (2005) LAAR, 35, pp. 217-224 
504 |a Armentano, R.L., Cabrera Fischer, E.I., Systemic Circulation: Arteries Function (2001) Cardiovascular Failure: Pathophysiological Bases and Management, pp. 73-110. , Fischer EIC, Christen AI, Trainini JC. Chapter 3; Ed: Fundación Universitaria Dr. René Favaloro, Buenos Aires Argentina 
504 |a Takamoto, S., Nakajima, S., Okita, Y., Motomura, N., Yuasa, M., Sada, M., Imakita, M., Tsuji, T., Cryopreserved femoral arterial allografts for vascular access in hemodialysis (1998) Transplant Proc, 30 (7), pp. 3917-3919. , Nov 
504 |a Lin, P.H., Brinkman, W.T., Terramani, T.T., Lumsden, A.B., Management of infected hemodialysis access grafts using cryopreserved human vein allografts (2002) Am J Surg, 184 (1), pp. 31-36. , Jul 
504 |a Madden, R.L., Lipkowitz, G.S., Browne, B.J., Kurbanov, A., Experience with cryopreserved cadaveric femoral vein allografts used for hemodialysis access (2002) Ann Vasc Surg, 18 (4), pp. 453-458. , Jul 
504 |a Roy-Chaudhurry, P., Kelly, B.S., Narayana, A., Desai, P., Melhem, M., Munda, R., Duncan, H., Heffelfinger, S.C., Hemodialysis Vascular Access Dysfunction From Basic Biology to Clinical Intervention (2002) Advanced in Renal Replacement Therapy, 9 (2), pp. 74-84 
504 |a Nguyen, V.D., Griffith, C., Treat, L., Multidisciplinary Team Approach to Increasing AV Fistula Creation (2003) Nephrology News & Issues, pp. 54-62 
504 |a Seifalian, A.M., Tiwari, A., Hamilton, G., Salacinski, H.J., Improving the clinical patency of prosthetic vascular and coronary bypass grafts: The role of seeding and tissue engineering (2002) Artificial Organs, 26 (4), pp. 307-320 
504 |a Joanides, R., Costentin, A., Iacob, M., Bakkali, E.H., Richard, M.O., Thuillez, C., Role of arterial smooth muscle tone and geometry in the regulation of peripheral conduit artery mechanics by shear stress (2001) Clin Exp Pharmacol Physiol, 28, pp. 1025-1031 
504 |a Cabrera Fischer, E.I., Armentano, R.L., Pessana, F.M., Graf, S., Romero, L., Christen, A.I., Simon, A., Levenson, J., Endothelium-dependent arterial wall tone elasticity modulated by blood viscosity (2002) Am J Physiol Heart Circ Physiol, 282, pp. 389-394 
504 |a Hofstra, L., Bergamns, D.C.J.J., Leunissen, K.M.L., Hoeks, A.P.G., Kitslaar, P.J.E.H.M., Daemen, M.J.A.P., Tordoir, J.H.M., Anastomotic Intimal Hyperplasia in Prosthetic Arteriovenous Fistulas for Hemodialysis Is Associated with Initial High Flow Velocity and Not with Mismatch in Elastic Propierties (1995) J Am Soc Nephrol, 6, pp. 1625-1633 
504 |a Safar, M.E., London, G.M., Plante, G.E., Arterial stiffness and kidney function (2004) Hypertension, 43, pp. 163-168 
504 |a Palma, J.L., Métodos no invasivos para la evaluación de las propiedades físicas de las grandes arterias en la hipertensión arterial (2002) Nefrología, 22, pp. 16-20 
504 |a Nitta, K., Akiba, T., Uchida, K., Otsubo, S., Otsubo, Y., Takei, T., Ogawa, T., Nihei, H., Left ventricular hypertrophy is associated with arterial stiffness and vascular calcification in hemodialysis patients (2004) Hypertens Res, 27, pp. 47-52 
504 |a Westerbacka, J., Uosukainen, A., Mäkimattila, S., Schlenzka, A., Yki-Järvinen, H., Insulin-induced decrease in large artery stiffness is impaired in uncomplicated type 1 Diabetes Mellitus (2000) Hypertension, 35, pp. 1043-1048 
504 |a Cohen, D.L., Warburton, K.M., Warren, G., Bloom, R.D., Towsend, R.R., Pulse wave analysis to assess vascular compliance changes in stable renal transplant recipients (2004) Am J Hypertens, 17, pp. 209-212 
504 |a Dobrin, P.B., Mirande, R., Kang, S., Dong, Q.S., Mrkvicka, R., Mechanics of end-to-end artery-to-PTFE grafo anastomoses (1998) Ann Vasc Surg, 12, pp. 317-323 
520 3 |a Intimal hyperplasia development is recognized as the most important cause of vascular access failure in patients submitted renal function replacement therapy. An important factor that affects the development of intimal hyperplasia is elastic mismatch between native vessel and among vein, arteries and the synthetic graft. In this work, a biomechanical analysis of cryopreserved arteries, expanded polytetrafluoroethylene (ePTFE), and fresh arteries and veins is reported. In vitro pressure (Konigsberg) and diameter (Sonomicrometry) were measured in fresh human vein and arteries and cryopreserved human defrosted arteries and ePTFE prosthesis, under isobaric and systemic pressures levels. Our results showed that ePTFE conduits have an elastic index which is significantly different from that of fresh and cryopreserved defrosted arteries and veins. These stiffness differences determine a high elastic mismatch. We conclude that this study of tubular segments to be used as vascular accesses in dialyzed patients, demonstrate significantly elastic differences that could be an important determinant of late access viability.  |l eng 
593 |a Departamento de Fisiología, Facultad de Medicina, Universidad de la República, Montevideo, Uruguay 
593 |a Instituto Nacional de Donación y Trasplante de Células Tejidos y Organos, Facultad de Medicina, Universidad de la República, Montevideo, Uruguay 
593 |a Departamento de Ingeniería Cardiovascular, Facultad Regional Buenos Aires, Universidad Tecnológica Nacional, Medrano 951, Buenos Aires, Argentina 
593 |a Facultad de Ingeniería y Ciencias Exactas y Naturales, Universidad Favaloro, Buenos Aires, Argentina 
593 |a ESFUNO, Facultad de Enfermería, Universidad de la República, Montevideo, Uruguay 
690 1 0 |a POLITEF 
690 1 0 |a ARTERIAL PRESSURE 
690 1 0 |a ARTERY DIAMETER 
690 1 0 |a ARTICLE 
690 1 0 |a BIOMECHANICS 
690 1 0 |a BLOOD VESSEL COMPLIANCE 
690 1 0 |a BLOOD VESSEL PARAMETERS 
690 1 0 |a CONTROLLED STUDY 
690 1 0 |a CRYOPRESERVATION 
690 1 0 |a ELASTICITY 
690 1 0 |a HEMODIALYSIS 
690 1 0 |a HEMODIALYSIS PATIENT 
690 1 0 |a HUMAN 
690 1 0 |a HUMAN TISSUE 
690 1 0 |a IN VITRO STUDY 
690 1 0 |a PNEUMATIC TOOL 
690 1 0 |a POLITEF IMPLANT 
690 1 0 |a TREATMENT OUTCOME 
690 1 0 |a ULTRASOUND 
690 1 0 |a VASCULAR ACCESS 
690 1 0 |a VEIN DIAMETER 
690 1 0 |a VENOUS PRESSURE 
653 0 0 |a Gore-Tex Vascular graft, Gore, United States; Jarvik, Kollf Medical, United States 
700 1 |a Pérez Campos, H. 
700 1 |a Galli, C.N. 
700 1 |a Saldías, M. 
700 1 |a Camus, J.M. 
700 1 |a Silva, W. 
700 1 |a Bia Santana, D. 
700 1 |a Álvarez, O. 
700 1 |a Álvarez, I. 
700 1 |a Armentano, R. 
773 0 |d 2005  |g v. 25  |h pp. 141-146  |k n. 4  |p Rev. Nefrol. Dial. Transplant.  |x 03263428  |t Revista de Nefrologia, Dialisis y Trasplante 
856 4 1 |u http://www.scopus.com/inward/record.url?eid=2-s2.0-32044471046&partnerID=40&md5=7e249f506f800c789f2dea32454c7545  |y Registro en Scopus 
856 4 0 |u https://hdl.handle.net/20.500.12110/paper_03263428_v25_n4_p141_Zocalo  |y Handle 
856 4 0 |u https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03263428_v25_n4_p141_Zocalo  |y Registro en la Biblioteca Digital 
961 |a paper_03263428_v25_n4_p141_Zocalo  |b paper  |c PE 
962 |a info:eu-repo/semantics/article  |a info:ar-repo/semantics/artículo  |b info:eu-repo/semantics/publishedVersion 
999 |c 64779