Simple fast light detector device based on a 1P28 photomultiplier tube
A simple implementation of the stroboscopic optical boxcar technique for determining intensity profiles of repetitive nanoseconds light pulses is presented. The device, implemented with standard components and a 1P28 photomultiplier tube, can be used for fluorescence decay measurements with subnanos...
Guardado en:
| Autor principal: | |
|---|---|
| Otros Autores: | , |
| Formato: | Capítulo de libro |
| Lenguaje: | Inglés |
| Publicado: |
1997
|
| Acceso en línea: | Registro en Scopus DOI Handle Registro en la Biblioteca Digital |
| Aporte de: | Registro referencial: Solicitar el recurso aquí |
| LEADER | 02236caa a22003257a 4500 | ||
|---|---|---|---|
| 001 | PAPER-19967 | ||
| 003 | AR-BaUEN | ||
| 005 | 20250623095101.0 | ||
| 008 | 190411s1997 xx ||||fo|||| 00| 0 eng|d | ||
| 024 | 7 | |2 scopus |a 2-s2.0-85010159188 | |
| 040 | |a Scopus |b spa |c AR-BaUEN |d AR-BaUEN | ||
| 100 | 1 | |a Libertun, Ariel Rubén | |
| 245 | 1 | 0 | |a Simple fast light detector device based on a 1P28 photomultiplier tube |
| 260 | |c 1997 | ||
| 504 | |a James, D.R., Stroboscopic optical boxcar technique for the determination of fluorescence lifetimes (1992) Rev. Sci. Instrum., 63 (2), p. 1710 | ||
| 504 | |a Matsushima, I., Single pulse switchout system for a passively mode-locked Q-switched Nd:YAG laser (1981) Rev. Sci. Instrum., 52, p. 1860 | ||
| 504 | |a Henebry, W.M., Avalanche transistor circuits (1961) Rev. Sci. Instrum., 32, p. 1198 | ||
| 506 | |2 openaire |e Política editorial | ||
| 520 | 3 | |a A simple implementation of the stroboscopic optical boxcar technique for determining intensity profiles of repetitive nanoseconds light pulses is presented. The device, implemented with standard components and a 1P28 photomultiplier tube, can be used for fluorescence decay measurements with subnanosecond time resolution. © 1997 Optical Society of America. |l eng | |
| 593 | |a Laboratorio de Electrónica Cuántica, Departamento de Física, Universidad de Buenos Aires, Ciudad Universitaria, Buenos Aires, Argentina | ||
| 700 | 1 | |a Marconi, Mario Carlos | |
| 700 | 1 | |a Sánchez, G. | |
| 773 | 0 | |d 1997 |g v. 36 |h pp. 9115-9116 |k n. 34 |p Appl. Opt. |x 1559128X |t Applied Optics | |
| 856 | 4 | 1 | |u https://www.scopus.com/inward/record.uri?eid=2-s2.0-85010159188&doi=10.1364%2fAO.36.009115&partnerID=40&md5=00423de3db2d8d1b1031d9b395b766c1 |y Registro en Scopus |
| 856 | 4 | 0 | |u https://doi.org/10.1364/AO.36.009115 |y DOI |
| 856 | 4 | 0 | |u https://hdl.handle.net/20.500.12110/paper_1559128X_v36_n34_p9115_Libertun |y Handle |
| 856 | 4 | 0 | |u https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_1559128X_v36_n34_p9115_Libertun |y Registro en la Biblioteca Digital |
| 961 | |a paper_1559128X_v36_n34_p9115_Libertun |b paper |c PE | ||
| 962 | |a info:eu-repo/semantics/article |a info:ar-repo/semantics/artículo |b info:eu-repo/semantics/publishedVersion | ||
| 999 | |c 80920 | ||