Simple fast light detector device based on a 1P28 photomultiplier tube

A simple implementation of the stroboscopic optical boxcar technique for determining intensity profiles of repetitive nanoseconds light pulses is presented. The device, implemented with standard components and a 1P28 photomultiplier tube, can be used for fluorescence decay measurements with subnanos...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Libertun, Ariel Rubén
Otros Autores: Marconi, Mario Carlos, Sánchez, G.
Formato: Capítulo de libro
Lenguaje:Inglés
Publicado: 1997
Acceso en línea:Registro en Scopus
DOI
Handle
Registro en la Biblioteca Digital
Aporte de:Registro referencial: Solicitar el recurso aquí
LEADER 02236caa a22003257a 4500
001 PAPER-19967
003 AR-BaUEN
005 20250623095101.0
008 190411s1997 xx ||||fo|||| 00| 0 eng|d
024 7 |2 scopus  |a 2-s2.0-85010159188 
040 |a Scopus  |b spa  |c AR-BaUEN  |d AR-BaUEN 
100 1 |a Libertun, Ariel Rubén 
245 1 0 |a Simple fast light detector device based on a 1P28 photomultiplier tube 
260 |c 1997 
504 |a James, D.R., Stroboscopic optical boxcar technique for the determination of fluorescence lifetimes (1992) Rev. Sci. Instrum., 63 (2), p. 1710 
504 |a Matsushima, I., Single pulse switchout system for a passively mode-locked Q-switched Nd:YAG laser (1981) Rev. Sci. Instrum., 52, p. 1860 
504 |a Henebry, W.M., Avalanche transistor circuits (1961) Rev. Sci. Instrum., 32, p. 1198 
506 |2 openaire  |e Política editorial 
520 3 |a A simple implementation of the stroboscopic optical boxcar technique for determining intensity profiles of repetitive nanoseconds light pulses is presented. The device, implemented with standard components and a 1P28 photomultiplier tube, can be used for fluorescence decay measurements with subnanosecond time resolution. © 1997 Optical Society of America.  |l eng 
593 |a Laboratorio de Electrónica Cuántica, Departamento de Física, Universidad de Buenos Aires, Ciudad Universitaria, Buenos Aires, Argentina 
700 1 |a Marconi, Mario Carlos 
700 1 |a Sánchez, G. 
773 0 |d 1997  |g v. 36  |h pp. 9115-9116  |k n. 34  |p Appl. Opt.  |x 1559128X  |t Applied Optics 
856 4 1 |u https://www.scopus.com/inward/record.uri?eid=2-s2.0-85010159188&doi=10.1364%2fAO.36.009115&partnerID=40&md5=00423de3db2d8d1b1031d9b395b766c1  |y Registro en Scopus 
856 4 0 |u https://doi.org/10.1364/AO.36.009115  |y DOI 
856 4 0 |u https://hdl.handle.net/20.500.12110/paper_1559128X_v36_n34_p9115_Libertun  |y Handle 
856 4 0 |u https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_1559128X_v36_n34_p9115_Libertun  |y Registro en la Biblioteca Digital 
961 |a paper_1559128X_v36_n34_p9115_Libertun  |b paper  |c PE 
962 |a info:eu-repo/semantics/article  |a info:ar-repo/semantics/artículo  |b info:eu-repo/semantics/publishedVersion 
999 |c 80920