Caracterización de tensiómetro multicámaras II : parámetros antropométricos

La hipertensión arterial es reconocida como uno de los principales factores de riesgo de enfermedad cardiovascular, renal y del sistema nervioso central y periférico, por lo que la medición de la presión arterial para su diagnóstico es fundamental a fin de adoptar las medidas terapéuticas necesarias...

Descripción completa

Detalles Bibliográficos
Autores principales: Arena, Lucía Elizabeth (Autor, autor), Caranti, Giorgio Mario (autor), Mac Garry, N. F. (autor), Rodríguez Aranciva, R. (autor)
Formato: Capítulo de libro
Lenguaje:Español
Publicado: Villa Martelli, Buenos Aires : Asociación Física Argentina, 2011
Materias:
Acceso en línea:Registro en la Biblioteca Digital
PDF
Handle
DOI
Aporte de:Registro referencial: Solicitar el recurso aquí
LEADER 07562naa a22005897a 4500
003 AR-BaUEN
005 20230802145531.0
008 220707s2011 ag ado|fo|||| 000 0 spa d
022 |a 1850-1168 
040 |a AR-BaUEN  |b spa 
041 0 |b spa  |b eng 
100 1 |4 aut  |a Arena, Lucía Elizabeth  |e autor  |g arena@famaf.unc.edu.ar  |u Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía y Física (UNC-FaMaF). Córdoba. Argentina 
245 1 0 |a Caracterización de tensiómetro multicámaras II :   |b parámetros antropométricos 
246 3 1 |a Characterization of multichambers tensiometer II :   |b anthropometric parameters 
260 |a Villa Martelli, Buenos Aires :  |b Asociación Física Argentina,  |c 2011 
270 |m arena@famaf.unc.edu.ar  |z Correo electrónico del Autor de correspondencia 
300 |a p. 79-83 :   |b il., fotos, gráfs. 
504 |a Referencias bibliográficas. 
506 |2 openaire  |e Acuerdo editorial  |f info:eu-repo/semantics/openAccess 
518 |o Fecha de publicación en la Biblioteca Digital FCEN-UBA  |d 2023-03-23 
520 3 |a La hipertensión arterial es reconocida como uno de los principales factores de riesgo de enfermedad cardiovascular, renal y del sistema nervioso central y periférico, por lo que la medición de la presión arterial para su diagnóstico es fundamental a fin de adoptar las medidas terapéuticas necesarias para prevenir y tratar esta patología. El método más utilizado para medir la presión arterial (PA) es el no invasivo por auscultación que requiere de un estetoscopio y un esfigmomanómetro; este último se compone de un brazalete con una cámara inflable para aplicar la presión y un manómetro. Una de las variables que afectan la medición de la presión es de cubrimiento del brazo con el brazalete, por ello en la actualidad se diseñan brazaletes con varias cámaras de presión que se adecuan a diferentes dimensiones braquiales. En el presente trabajo se estudia un nuevo esfigmomanómetro con un brazalete multicámaras, TMU-2, en función de parámetros antropométricos del paciente como el perímetro de brazo y el largo del brazo. Se midió la PA por métodos invasivo y no invasivos de pacientes internados en una Unidad de Terapia Intensiva y estabilizados. Las presiones intraarteriales, medidas por el método directo invasivo, se tomaron como patrón de referencia para estudiar las presiones medidas por métodos no invasivos utilizando dos esfigmomanómetros (medición indirecta por auscultación): el multicámaras TMU-2 y uno clásico (cámara de 12cmx22cm), de uso común en la práctica clínica. Los resultados muestran que la dispersión de los valores de PA obtenidos con el esfigmomanómetro multicámaras en función del perímetro del brazo es menor que la observada en los valores obtenidos con el esfigmomanómetro clásico, especialmente para valores de perímetros de brazo mayores (30-32 cm), donde se reduce aproximadamente a la mitad. Este resultado es relevante ya que el diagnóstico del paciente puede cambiar notablemente si se utiliza el tensiómetro clásico o el TMU2, en particular en el caso de los pacientes obesos, frecuentemente hipertensos, y el tratamiento a seguir depende fuertemente de que sean correctamente clasificados en función de su tensión arterial. Resultados similares se observan para otros parámetros antropométricos, donde el TMU2 tiene un comportamiento menos dependiente del parámetro que el tensiómetro clásico de una cámara  |l spa 
520 3 |a Hypertension is recognized as one of the main risk factors for cardiovascular, renal and central and peripheral nervous system disease, so that measuring blood pressure (BP) for diagnosis is essential to adopt measures necessary to prevent and treat this disease. The preferred method is noninvasive by auscultation requiring a stethoscope and a sphygmomanometer, the latter consists of a cuff to apply pressure and a manometer. One of the variables that affect the pressure measurement is made covering the cuff arm; therefore currently bracelets are designed with several pressure chambers hich are adapted to different dimensions brachii. In this paper we study a new multichamber cuff bracelet, TMU-2, based on anthropometric parameters of patient as arm circumference and upper arm length. We used data of blood pressure obtained by invasive and noninvasive methods, of patients in Intensive Care Unit and stabilized. The intraarterial pressures measured by the direct method invasive are the benchmarks for non-invasive study pressures. These were measured by two sphygmomanometers (measured indirectly by auscultation): The multichamber TMU-2 and one classic (12x22cm camera), commonly used in clinical practice. When taken the intraarterial pressures as benchmarks, the results show that the scattering of the blood pressure values obtained with the multichamber sphygmomanometer according to the perimeter of the arm is lower than that observed in the values obtained with the classic sphygmomanometer, especially for values of perimeters larger arm (30-32 cm), which is reduced approximately by half. This result is important because diagnosis of the patient changes significantly when using the classic or TMU2 blood pressure, in particular in the case of obese patients, frequently with hypertension, and the treatment to follow depends strongly that they are properly classified according to their blood pressure. Similar results were observed for other anthropometric parameters, where TMU2 behaves less dependent on the tensiometer classic parameter of a camera  |l eng 
540 |2 cc  |f https://creativecommons.org/licenses/by-nc-sa/2.5/ar 
653 1 0 |a PRESION ARTERIAL 
653 1 0 |a ESFINGOMANOMETRO 
653 1 0 |a TENSIOMETRO 
653 1 0 |a MULTICAMARAS 
653 1 0 |a INTRAARTERIAL 
653 1 0 |a PARAMETROS ANTROPOMETRICOS 
690 1 0 |a BLOOD PRESSURE CUFF 
690 1 0 |a ESFIGMOMANOMETER 
690 1 0 |a CUFF 
690 1 0 |a BLOOD PRESSURE 
690 1 0 |a MULTICHAMBER 
690 1 0 |a INTRAARTERIAL 
690 1 0 |a ANTHROPOMETRIC PARAMETERS 
700 1 |4 aut  |a Caranti, Giorgio Mario  |e autor  |u Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía y Física (UNC-FaMaF). Córdoba. Argentina 
700 1 |4 aut  |a Mac Garry, N. F.  |e autor  |u Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía y Física (UNC-FaMaF). Córdoba. Argentina 
700 1 |4 aut  |a Rodríguez Aranciva, R.  |e autor  |u Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía y Física (UNC-FaMaF). Córdoba. Argentina 
773 0 |d Villa Martelli, Buenos Aires. Asociación Física Argentina,   |g v. 23  |h pp. 79-83  |k n. 01  |p An. (Asoc. Fís. Argent., En línea)  |w (AR-BaUEN)CENRE-9838  |x 1850-1168  |t Anales AFA 
856 4 1 |q application/pdf  |u https://bibliotecadigital.exactas.uba.ar/collection/afa/document/afa_v23_n01_p079  |x registro  |y Registro en la Biblioteca Digital 
856 4 1 |q application/pdf  |u https://bibliotecadigital.exactas.uba.ar/download/afa/afa_v23_n01_p079.pdf  |x derivado  |y PDF 
856 4 1 |q application/pdf  |u https://hdl.handle.net/20.500.12110/afa_v23_n01_p079  |x hdl  |y Handle 
856 4 1 |q application/pdf  |u https://doi.org/10.31527/analesafa.2013.223.1.79  |x doi  |y DOI 
901 |l 28  |m Juan Cristobal Sotomayor Chacon  |n 56678  |q Lucía Bongiovanni 
942 |c ASER  |n 0 
961 |a afa_v23_n01_p079  |b afa  |c PU  |e ND 
962 |a info:ar-repo/semantics/artículo  |a info:eu-repo/semantics/article  |b info:eu-repo/semantics/publishedVersion 
963 |a AA 
976 |a AEX 
999 |c 90406  |d 90406 
044 |a ag