Herramienta de chequeo de registro xml obtenido desde Repositorio Institucional Centro Atómico Bariloche e Instituto Balseiro (RICABIB)

XML

<oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><identifier>I25-R131-954</identifier><datestamp>2021-07-30T13:46:22Z</datestamp>
        <dc:title>Cálculo de factores de conversión para la estimación de la tasa de dosis en piel debido a contaminación superficial </dc:title>
        <dc:title_english>Calculation of conversion factors to estimate the dose rate on skin due to surface contamination</dc:title_english>
        <dc:creator>Pasquevich, Ian L.</dc:creator>
        <dc:subject>Protección radiológica del paciente</dc:subject>
        <dc:subject>Skin</dc:subject>
        <dc:subject>Piel</dc:subject>
        <dc:subject>Contamination</dc:subject>
        <dc:subject>Contaminación</dc:subject>
        <dc:subject>Monte Carlo Method</dc:subject>
        <dc:subject>Método de Monte Carlo</dc:subject>
        <dc:subject>Doses</dc:subject>
        <dc:subject>Dosis</dc:subject>
        <dc:subject>[Conversion factor</dc:subject>
        <dc:subject>Factores de conversión]</dc:subject>
        <dc:description>El uso de radioisótopos en servicios de medicina nuclear, así como también en reactores&#13;
de investigación, puede producir contaminaciones en piel debido a accidentes o&#13;
descuidos del personal. Se ha mostrado que esta contaminación contribuye considerablemente&#13;
a la dosis total en piel recibida por los técnicos en medicina nuclear, pudiendo&#13;
exceder fácilmente el límite de 500 mSv/año establecido por la normativa vigente.&#13;
Para evaluar la severidad de la contaminación es necesario estimar la dosis en piel a&#13;
través del uso de factores de conversión de tasa de dosis en piel adecuados. Para poder&#13;
determinar los factores apropiados es importante estudiar la in&#13;
fluencia del área de&#13;
contaminación, del espesor epidérmico y de la absorción percutánea sobre los mismos.&#13;
En este trabajo se utilizaron simulaciones Monte-Carlo para el estudio y cuanticación&#13;
de los factores de conversión dosimétricos de 15 radioisótopos.&#13;
Los resultados mostraron que la dosis absorbida en piel es signicativamente in-&#13;
&#13;
fluenciada por el espesor epidérmico y la absorción percutánea, pudiendo diferir hasta&#13;
en dos órdenes de magnitud con respecto a la magnitud operacional H´(0.07,0º).</dc:description>
        <dc:description_english>The use of radioisotopes in nuclear medicine services, as well as in research reactors,&#13;
can lead to skin contamination due to accidents or staff oversight. This contamination&#13;
has been shown to contribute considerably to the total skin dose received by nuclear&#13;
medicine technicians, and can easily exceed the limit of 500 mSv/year established by&#13;
current regulations.&#13;
To assess the severity of contamination, it is necessary to estimate the skin dose&#13;
through the use of suitable skin dose rate conversion factors. In order to determine&#13;
the appropriate factors, it is important to study the in&#13;
fluence of the contamination&#13;
area, the epidermal thickness and the percutaneous absorption on them. In this work,&#13;
Monte-Carlo simulations were used to study and quantify the dosimetric conversion&#13;
factors of 15 radioisotopes.&#13;
The results showed that the absorbed dose to the skin is signicantly in&#13;
fluenced by&#13;
epidermal thickness and percutaneous absorption, and can differ by up to two orders&#13;
of magnitude with respect to the operational magnitude H´(0.07,0º).</dc:description_english>
        <dc:date>2021-02-24</dc:date>
        <dc:type>Tesis</dc:type>
        <dc:type>NonPeerReviewed</dc:type>
        <dc:format>application/pdf</dc:format>
        <dc:identifier>http://ricabib.cab.cnea.gov.ar/954/1/1Pasquevich.pdf</dc:identifier>
        <dc:language>es</dc:language>
        <dc:identifier>Pasquevich, Ian L. (2021) Cálculo de factores de conversión para la estimación de la tasa de dosis en piel debido a contaminación superficial / Calculation of conversion factors to estimate the dose rate on skin due to surface contamination. Maestría en Física Médica, Universidad Nacional de Cuyo, Instituto Balseiro.</dc:identifier>
        <dc:relation>http://ricabib.cab.cnea.gov.ar/954/</dc:relation></oai_dc:dc>

Datos convertidos

{
    "id": "I25-R131-954",
    "record_format": "dspace",
    "spelling": [
        "I25-R131-9542021-07-30T13:46:22Z C\u00e1lculo de factores de conversi\u00f3n para la estimaci\u00f3n de la tasa de dosis en piel debido a contaminaci\u00f3n superficial Calculation of conversion factors to estimate the dose rate on skin due to surface contamination Pasquevich, Ian L. Protecci\u00f3n radiol\u00f3gica del paciente Skin Piel Contamination Contaminaci\u00f3n Monte Carlo Method M\u00e9todo de Monte Carlo Doses Dosis [Conversion factor Factores de conversi\u00f3n] El uso de radiois\u00f3topos en servicios de medicina nuclear, as\u00ed como tambi\u00e9n en reactores de investigaci\u00f3n, puede producir contaminaciones en piel debido a accidentes o descuidos del personal. Se ha mostrado que esta contaminaci\u00f3n contribuye considerablemente a la dosis total en piel recibida por los t\u00e9cnicos en medicina nuclear, pudiendo exceder f\u00e1cilmente el l\u00edmite de 500 mSv\/a\u00f1o establecido por la normativa vigente. Para evaluar la severidad de la contaminaci\u00f3n es necesario estimar la dosis en piel a trav\u00e9s del uso de factores de conversi\u00f3n de tasa de dosis en piel adecuados. Para poder determinar los factores apropiados es importante estudiar la in fluencia del \u00e1rea de contaminaci\u00f3n, del espesor epid\u00e9rmico y de la absorci\u00f3n percut\u00e1nea sobre los mismos. En este trabajo se utilizaron simulaciones Monte-Carlo para el estudio y cuanticaci\u00f3n de los factores de conversi\u00f3n dosim\u00e9tricos de 15 radiois\u00f3topos. Los resultados mostraron que la dosis absorbida en piel es signicativamente in- fluenciada por el espesor epid\u00e9rmico y la absorci\u00f3n percut\u00e1nea, pudiendo diferir hasta en dos \u00f3rdenes de magnitud con respecto a la magnitud operacional H\u00b4(0.07,0\u00ba). The use of radioisotopes in nuclear medicine services, as well as in research reactors, can lead to skin contamination due to accidents or staff oversight. This contamination has been shown to contribute considerably to the total skin dose received by nuclear medicine technicians, and can easily exceed the limit of 500 mSv\/year established by current regulations. To assess the severity of contamination, it is necessary to estimate the skin dose through the use of suitable skin dose rate conversion factors. In order to determine the appropriate factors, it is important to study the in fluence of the contamination area, the epidermal thickness and the percutaneous absorption on them. In this work, Monte-Carlo simulations were used to study and quantify the dosimetric conversion factors of 15 radioisotopes. The results showed that the absorbed dose to the skin is signicantly in fluenced by epidermal thickness and percutaneous absorption, and can differ by up to two orders of magnitude with respect to the operational magnitude H\u00b4(0.07,0\u00ba). 2021-02-24 Tesis NonPeerReviewed application\/pdf http:\/\/ricabib.cab.cnea.gov.ar\/954\/1\/1Pasquevich.pdf es Pasquevich, Ian L. (2021) C\u00e1lculo de factores de conversi\u00f3n para la estimaci\u00f3n de la tasa de dosis en piel debido a contaminaci\u00f3n superficial \/ Calculation of conversion factors to estimate the dose rate on skin due to surface contamination. Maestr\u00eda en F\u00edsica M\u00e9dica, Universidad Nacional de Cuyo, Instituto Balseiro. http:\/\/ricabib.cab.cnea.gov.ar\/954\/"
    ],
    "institution": [
        "Instituto Balseiro"
    ],
    "institution_str": "I-25",
    "repository_str": "R-131",
    "collection": [
        "Repositorio Institucional Centro At\u00f3mico Bariloche e Instituto Balseiro (RICABIB)"
    ],
    "language": [
        "Espa\u00f1ol"
    ],
    "orig_language_str_mv": [
        "es"
    ],
    "topic": [
        "Protecci\u00f3n radiol\u00f3gica del paciente",
        "Skin",
        "Piel",
        "Contamination",
        "Contaminaci\u00f3n",
        "Monte Carlo Method",
        "M\u00e9todo de Monte Carlo",
        "Doses",
        "Dosis",
        "[Conversion factor",
        "Factores de conversi\u00f3n]"
    ],
    "spellingShingle": [
        "Protecci\u00f3n radiol\u00f3gica del paciente",
        "Skin",
        "Piel",
        "Contamination",
        "Contaminaci\u00f3n",
        "Monte Carlo Method",
        "M\u00e9todo de Monte Carlo",
        "Doses",
        "Dosis",
        "[Conversion factor",
        "Factores de conversi\u00f3n]",
        "Pasquevich, Ian L.",
        "C\u00e1lculo de factores de conversi\u00f3n para la estimaci\u00f3n de la tasa de dosis en piel debido a contaminaci\u00f3n superficial "
    ],
    "topic_facet": [
        "Protecci\u00f3n radiol\u00f3gica del paciente",
        "Skin",
        "Piel",
        "Contamination",
        "Contaminaci\u00f3n",
        "Monte Carlo Method",
        "M\u00e9todo de Monte Carlo",
        "Doses",
        "Dosis",
        "[Conversion factor",
        "Factores de conversi\u00f3n]"
    ],
    "description": "El uso de radiois\u00f3topos en servicios de medicina nuclear, as\u00ed como tambi\u00e9n en reactores\r\nde investigaci\u00f3n, puede producir contaminaciones en piel debido a accidentes o\r\ndescuidos del personal. Se ha mostrado que esta contaminaci\u00f3n contribuye considerablemente\r\na la dosis total en piel recibida por los t\u00e9cnicos en medicina nuclear, pudiendo\r\nexceder f\u00e1cilmente el l\u00edmite de 500 mSv\/a\u00f1o establecido por la normativa vigente.\r\nPara evaluar la severidad de la contaminaci\u00f3n es necesario estimar la dosis en piel a\r\ntrav\u00e9s del uso de factores de conversi\u00f3n de tasa de dosis en piel adecuados. Para poder\r\ndeterminar los factores apropiados es importante estudiar la in\r\nfluencia del \u00e1rea de\r\ncontaminaci\u00f3n, del espesor epid\u00e9rmico y de la absorci\u00f3n percut\u00e1nea sobre los mismos.\r\nEn este trabajo se utilizaron simulaciones Monte-Carlo para el estudio y cuanticaci\u00f3n\r\nde los factores de conversi\u00f3n dosim\u00e9tricos de 15 radiois\u00f3topos.\r\nLos resultados mostraron que la dosis absorbida en piel es signicativamente in-\r\n\r\nfluenciada por el espesor epid\u00e9rmico y la absorci\u00f3n percut\u00e1nea, pudiendo diferir hasta\r\nen dos \u00f3rdenes de magnitud con respecto a la magnitud operacional H\u00b4(0.07,0\u00ba).",
    "format": [
        "Tesis",
        "NonPeerReviewed"
    ],
    "author": [
        "Pasquevich, Ian L."
    ],
    "author_facet": [
        "Pasquevich, Ian L."
    ],
    "author_sort": "Pasquevich, Ian L.",
    "title": "C\u00e1lculo de factores de conversi\u00f3n para la estimaci\u00f3n de la tasa de dosis en piel debido a contaminaci\u00f3n superficial ",
    "title_short": "C\u00e1lculo de factores de conversi\u00f3n para la estimaci\u00f3n de la tasa de dosis en piel debido a contaminaci\u00f3n superficial ",
    "title_full": "C\u00e1lculo de factores de conversi\u00f3n para la estimaci\u00f3n de la tasa de dosis en piel debido a contaminaci\u00f3n superficial ",
    "title_fullStr": "C\u00e1lculo de factores de conversi\u00f3n para la estimaci\u00f3n de la tasa de dosis en piel debido a contaminaci\u00f3n superficial ",
    "title_full_unstemmed": "C\u00e1lculo de factores de conversi\u00f3n para la estimaci\u00f3n de la tasa de dosis en piel debido a contaminaci\u00f3n superficial ",
    "title_sort": "c\u00e1lculo de factores de conversi\u00f3n para la estimaci\u00f3n de la tasa de dosis en piel debido a contaminaci\u00f3n superficial",
    "publishDate": [
        "2021"
    ],
    "url": [
        "http:\/\/ricabib.cab.cnea.gov.ar\/954\/1\/1Pasquevich.pdf"
    ],
    "work_keys_str_mv": [
        "AT pasquevichianl calculodefactoresdeconversionparalaestimaciondelatasadedosisenpieldebidoacontaminacionsuperficial"
    ],
    "_version_": 1794277866833182720
}