Herramienta de chequeo de registro xml obtenido desde Repositorio Institucional Centro Atómico Bariloche e Instituto Balseiro (RICABIB)

XML

<oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><identifier>I25-R131-435</identifier><datestamp>2014-04-10T13:24:28Z</datestamp>
        <dc:title>Validación de código de cálculo CONDOR para redes de plantas de potencia en función quemado.</dc:title>
        <dc:title_english>Validation of CONDOR code for power plants against burnup.</dc:title_english>
        <dc:creator>Furlano, Lucas</dc:creator>
        <dc:subject>Sistemas de información</dc:subject>
        <dc:subject>Ingeniería nuclear</dc:subject>
        <dc:subject>Water cooled reactors</dc:subject>
        <dc:subject>Reactores refrigerados por agua</dc:subject>
        <dc:subject>Burnout</dc:subject>
        <dc:subject>Quemado</dc:subject>
        <dc:subject>Benchmarks</dc:subject>
        <dc:subject>Patrones</dc:subject>
        <dc:subject>[CONDOR code calculation</dc:subject>
        <dc:subject>Código de cálculo CONDOR]</dc:subject>
        <dc:description>En el presente trabajo se estudió la capacidad del código de cálculo CONDOR para resolver distintas redes en plantas de potencia LWR en función del quemado. Para esto, se realizó una validación del código ante Benchmarks de tipo numérico y experimental.&#13;
Los parámetros estudiados fueron, concentraciones isotópicas en función del quemado, distribución radial de ciertos isótopos a final de vida del EECC y cambios de reactividad para distintos estados de planta en distintas etapas de la vida del EECC.&#13;
Los modelos empleados se resolvieron con el método HRM evaluando las distintas posibilidades que ofrece el programa a la hora de definir las celdas y macroceldas. Se evaluó, además, la capacidad del código para simular la operación de las plantas de potencia.&#13;
Se contrastó los resultados obtenidos a partir de las bibliotecas de secciones eficaces Helios-190 y ESIN-2001. Las mismas poseen cadenas de quemado y un número de isótopos diferentes, lo que presume cierta discrepancia en el resultado para isótopos provenientes de cadenas de quemado complejas.</dc:description>
        <dc:description_english>In this work, it has been studied the capability of the neutronic calculatinoal code CONDOR to solve diferent burnup clusters in LWR power plants systems. For this achivement, it has been contrasted the results of the code with numerical and experimental Benchmarks.&#13;
The parameters studied were, isotopic composition versus burnup, radial distribution of certain isotopes at the end of life of the fuel element and reactivity changes for different states of plant and different burnup states. Furthermore, it has been evaluated the capability of the code to simulate the operation of the power plants.&#13;
For the validation it has been used the HRM resolution scheme, evaluating the dieferent posibilities that the program offers to define the cells and macrocells.&#13;
Allthough, it has been compared the results from libraries Helios-190 and ESIN-2001. Both have diferent burnup chains and a diferent amount of isotopes so, it is expected that the results for the isotopes from coplex burn up chains may have discrepancies.</dc:description_english>
        <dc:date>2013-06-26</dc:date>
        <dc:type>Tesis</dc:type>
        <dc:type>NonPeerReviewed</dc:type>
        <dc:format>application/pdf</dc:format>
        <dc:identifier>http://ricabib.cab.cnea.gov.ar/435/1/1Furlano.pdf</dc:identifier>
        <dc:language>es</dc:language>
        <dc:identifier>Furlano, Lucas (2013) Validación de código de cálculo CONDOR para redes de plantas de potencia en función quemado. / Validation of CONDOR code for power plants against burnup. Proyecto Integrador Ingeniería Nuclear, Universidad Nacional de Cuyo, Instituto Balseiro.</dc:identifier>
        <dc:relation>http://ricabib.cab.cnea.gov.ar/435/</dc:relation></oai_dc:dc>

Datos convertidos

{
    "id": "I25-R131-435",
    "record_format": "dspace",
    "spelling": [
        "I25-R131-4352014-04-10T13:24:28Z Validaci\u00f3n de c\u00f3digo de c\u00e1lculo CONDOR para redes de plantas de potencia en funci\u00f3n quemado. Validation of CONDOR code for power plants against burnup. Furlano, Lucas Sistemas de informaci\u00f3n Ingenier\u00eda nuclear Water cooled reactors Reactores refrigerados por agua Burnout Quemado Benchmarks Patrones [CONDOR code calculation C\u00f3digo de c\u00e1lculo CONDOR] En el presente trabajo se estudi\u00f3 la capacidad del c\u00f3digo de c\u00e1lculo CONDOR para resolver distintas redes en plantas de potencia LWR en funci\u00f3n del quemado. Para esto, se realiz\u00f3 una validaci\u00f3n del c\u00f3digo ante Benchmarks de tipo num\u00e9rico y experimental. Los par\u00e1metros estudiados fueron, concentraciones isot\u00f3picas en funci\u00f3n del quemado, distribuci\u00f3n radial de ciertos is\u00f3topos a final de vida del EECC y cambios de reactividad para distintos estados de planta en distintas etapas de la vida del EECC. Los modelos empleados se resolvieron con el m\u00e9todo HRM evaluando las distintas posibilidades que ofrece el programa a la hora de definir las celdas y macroceldas. Se evalu\u00f3, adem\u00e1s, la capacidad del c\u00f3digo para simular la operaci\u00f3n de las plantas de potencia. Se contrast\u00f3 los resultados obtenidos a partir de las bibliotecas de secciones eficaces Helios-190 y ESIN-2001. Las mismas poseen cadenas de quemado y un n\u00famero de is\u00f3topos diferentes, lo que presume cierta discrepancia en el resultado para is\u00f3topos provenientes de cadenas de quemado complejas. In this work, it has been studied the capability of the neutronic calculatinoal code CONDOR to solve diferent burnup clusters in LWR power plants systems. For this achivement, it has been contrasted the results of the code with numerical and experimental Benchmarks. The parameters studied were, isotopic composition versus burnup, radial distribution of certain isotopes at the end of life of the fuel element and reactivity changes for different states of plant and different burnup states. Furthermore, it has been evaluated the capability of the code to simulate the operation of the power plants. For the validation it has been used the HRM resolution scheme, evaluating the dieferent posibilities that the program offers to define the cells and macrocells. Allthough, it has been compared the results from libraries Helios-190 and ESIN-2001. Both have diferent burnup chains and a diferent amount of isotopes so, it is expected that the results for the isotopes from coplex burn up chains may have discrepancies. 2013-06-26 Tesis NonPeerReviewed application\/pdf http:\/\/ricabib.cab.cnea.gov.ar\/435\/1\/1Furlano.pdf es Furlano, Lucas (2013) Validaci\u00f3n de c\u00f3digo de c\u00e1lculo CONDOR para redes de plantas de potencia en funci\u00f3n quemado. \/ Validation of CONDOR code for power plants against burnup. Proyecto Integrador Ingenier\u00eda Nuclear, Universidad Nacional de Cuyo, Instituto Balseiro. http:\/\/ricabib.cab.cnea.gov.ar\/435\/"
    ],
    "institution": [
        "Instituto Balseiro"
    ],
    "institution_str": "I-25",
    "repository_str": "R-131",
    "collection": [
        "Repositorio Institucional Centro At\u00f3mico Bariloche e Instituto Balseiro (RICABIB)"
    ],
    "language": [
        "Espa\u00f1ol"
    ],
    "orig_language_str_mv": [
        "es"
    ],
    "topic": [
        "Sistemas de informaci\u00f3n",
        "Ingenier\u00eda nuclear",
        "Water cooled reactors",
        "Reactores refrigerados por agua",
        "Burnout",
        "Quemado",
        "Benchmarks",
        "Patrones",
        "[CONDOR code calculation",
        "C\u00f3digo de c\u00e1lculo CONDOR]"
    ],
    "spellingShingle": [
        "Sistemas de informaci\u00f3n",
        "Ingenier\u00eda nuclear",
        "Water cooled reactors",
        "Reactores refrigerados por agua",
        "Burnout",
        "Quemado",
        "Benchmarks",
        "Patrones",
        "[CONDOR code calculation",
        "C\u00f3digo de c\u00e1lculo CONDOR]",
        "Furlano, Lucas",
        "Validaci\u00f3n de c\u00f3digo de c\u00e1lculo CONDOR para redes de plantas de potencia en funci\u00f3n quemado."
    ],
    "topic_facet": [
        "Sistemas de informaci\u00f3n",
        "Ingenier\u00eda nuclear",
        "Water cooled reactors",
        "Reactores refrigerados por agua",
        "Burnout",
        "Quemado",
        "Benchmarks",
        "Patrones",
        "[CONDOR code calculation",
        "C\u00f3digo de c\u00e1lculo CONDOR]"
    ],
    "description": "En el presente trabajo se estudi\u00f3 la capacidad del c\u00f3digo de c\u00e1lculo CONDOR para resolver distintas redes en plantas de potencia LWR en funci\u00f3n del quemado. Para esto, se realiz\u00f3 una validaci\u00f3n del c\u00f3digo ante Benchmarks de tipo num\u00e9rico y experimental.\r\nLos par\u00e1metros estudiados fueron, concentraciones isot\u00f3picas en funci\u00f3n del quemado, distribuci\u00f3n radial de ciertos is\u00f3topos a final de vida del EECC y cambios de reactividad para distintos estados de planta en distintas etapas de la vida del EECC.\r\nLos modelos empleados se resolvieron con el m\u00e9todo HRM evaluando las distintas posibilidades que ofrece el programa a la hora de definir las celdas y macroceldas. Se evalu\u00f3, adem\u00e1s, la capacidad del c\u00f3digo para simular la operaci\u00f3n de las plantas de potencia.\r\nSe contrast\u00f3 los resultados obtenidos a partir de las bibliotecas de secciones eficaces Helios-190 y ESIN-2001. Las mismas poseen cadenas de quemado y un n\u00famero de is\u00f3topos diferentes, lo que presume cierta discrepancia en el resultado para is\u00f3topos provenientes de cadenas de quemado complejas.",
    "format": [
        "Tesis",
        "NonPeerReviewed"
    ],
    "author": [
        "Furlano, Lucas"
    ],
    "author_facet": [
        "Furlano, Lucas"
    ],
    "author_sort": "Furlano, Lucas",
    "title": "Validaci\u00f3n de c\u00f3digo de c\u00e1lculo CONDOR para redes de plantas de potencia en funci\u00f3n quemado.",
    "title_short": "Validaci\u00f3n de c\u00f3digo de c\u00e1lculo CONDOR para redes de plantas de potencia en funci\u00f3n quemado.",
    "title_full": "Validaci\u00f3n de c\u00f3digo de c\u00e1lculo CONDOR para redes de plantas de potencia en funci\u00f3n quemado.",
    "title_fullStr": "Validaci\u00f3n de c\u00f3digo de c\u00e1lculo CONDOR para redes de plantas de potencia en funci\u00f3n quemado.",
    "title_full_unstemmed": "Validaci\u00f3n de c\u00f3digo de c\u00e1lculo CONDOR para redes de plantas de potencia en funci\u00f3n quemado.",
    "title_sort": "validaci\u00f3n de c\u00f3digo de c\u00e1lculo condor para redes de plantas de potencia en funci\u00f3n quemado.",
    "publishDate": [
        "2013"
    ],
    "url": [
        "http:\/\/ricabib.cab.cnea.gov.ar\/435\/1\/1Furlano.pdf"
    ],
    "work_keys_str_mv": [
        "AT furlanolucas validaciondecodigodecalculocondorpararedesdeplantasdepotenciaenfuncionquemado"
    ],
    "_version_": 1794277777101291520
}