Herramienta de chequeo de registro xml obtenido desde Repositorio Institucional Centro Atómico Bariloche e Instituto Balseiro (RICABIB)

XML

<oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><identifier>I25-R131-386</identifier><datestamp>2013-02-07T14:19:01Z</datestamp>
        <dc:title>Metrología de Radiaciones en Reactores&#13;
EPR/L-Alanina&#13;
</dc:title>
        <dc:title_english>EPR/Alanine in RA6 Nuclear Reactor</dc:title_english>
        <dc:creator>Fainstein, Carlos</dc:creator>
        <dc:subject>Biología</dc:subject>
        <dc:subject>Física</dc:subject>
        <dc:subject>Diagnóstico por imagen y medicina nuclear</dc:subject>
        <dc:subject>EPR spectrometers</dc:subject>
        <dc:subject>Espectrómetros RPE</dc:subject>
        <dc:subject>Spectroscopy</dc:subject>
        <dc:subject>Espectroscopia</dc:subject>
        <dc:subject>Paramagnetism</dc:subject>
        <dc:subject>Paramagnetismo</dc:subject>
        <dc:subject>Ionizing radiations</dc:subject>
        <dc:subject>RA-6 reactor</dc:subject>
        <dc:subject>Reactor RA-6</dc:subject>
        <dc:subject>Argentine CNEA</dc:subject>
        <dc:subject>CNEA argentina</dc:subject>
        <dc:subject>Alanine-l</dc:subject>
        <dc:subject>Alanina-l</dc:subject>
        <dc:subject>Monte Carlo Method</dc:subject>
        <dc:subject>Método Monte Carlo</dc:subject>
        <dc:description>Mediante Espectrometría EPR medimos el paramagnetismo inducido, por radiación ionizante, en polvo cristalino de L-Alanina, irradiado en diferentes celdas del núcleo del Reactor de Investigación RA6 (Centro Atómico Bariloche/CNEA, Argentina). &#13;
Los espectros EPR son comparados con los obtenidos para L-Alanina irradiada con fotones de una fuente radiactiva calibrada (Co60), según las Normas ISO/ASTM51607-04 e ISO/ASTM51939-05.&#13;
Mostramos que este método dosimétrico es preciso, reproducible y confiable, como registro de operación de Reactores para Investigación; y que las dosis estimadas en RA6, mediante el Código Monte Carlo MCNP5 (Los Alamos National Laboratory, USA), resultan sobreestimadas, en todos los casos considerados.&#13;
</dc:description>
        <dc:description_english>EPR Spectroscopy is used to measure the radiation induced paramagnetism in L-Alanine crystalline powder, irradiated in different cells of the RA6 Nuclear Research Reactor, at the Centro Atomico Bariloche/CNEA, Bariloche, RN, Argentina. The EPR spectra are compared against those obtained by irradiating L-Alanine with a Calibrated Co60 Source (ISO/ASTM51607-04).&#13;
We show that L-Alanine/EPR Metrology is, accurate and reliable, and that can be used with advantage as a permanent record of the overall performance of Nuclear Research Reactors within the limitations of the Standard Practice ISO/ASTM51607-04 and ISO/ASTM51939-05. &#13;
Within those limits, our data suggest that the values of Dose for the different cells, estimated using the Code MCNP5 (Los Alamos National Laboratory, USA) are, in all cases, overestimated.&#13;
</dc:description_english>
        <dc:publisher>-</dc:publisher>
        <dc:date>2013-01</dc:date>
        <dc:type>Documento de trabajo</dc:type>
        <dc:type>NonPeerReviewed</dc:type>
        <dc:format>application/msword</dc:format>
        <dc:identifier>http://ricabib.cab.cnea.gov.ar/386/1/2013.0108.RA6.Trabajo.Metrologia.doc</dc:identifier>
        <dc:language>es</dc:language>
        <dc:identifier>Fainstein, Carlos (2013) Metrología de Radiaciones en Reactores EPR/L-Alanina / EPR/Alanine in RA6 Nuclear Reactor. Informe Técnico. -. (No publicado)</dc:identifier>
        <dc:relation>http://ricabib.cab.cnea.gov.ar/386/</dc:relation></oai_dc:dc>

Datos convertidos

{
    "id": "I25-R131-386",
    "record_format": "dspace",
    "spelling": [
        "I25-R131-3862013-02-07T14:19:01Z Metrolog\u00eda de Radiaciones en Reactores EPR\/L-Alanina EPR\/Alanine in RA6 Nuclear Reactor Fainstein, Carlos Biolog\u00eda F\u00edsica Diagn\u00f3stico por imagen y medicina nuclear EPR spectrometers Espectr\u00f3metros RPE Spectroscopy Espectroscopia Paramagnetism Paramagnetismo Ionizing radiations RA-6 reactor Reactor RA-6 Argentine CNEA CNEA argentina Alanine-l Alanina-l Monte Carlo Method M\u00e9todo Monte Carlo Mediante Espectrometr\u00eda EPR medimos el paramagnetismo inducido, por radiaci\u00f3n ionizante, en polvo cristalino de L-Alanina, irradiado en diferentes celdas del n\u00facleo del Reactor de Investigaci\u00f3n RA6 (Centro At\u00f3mico Bariloche\/CNEA, Argentina). Los espectros EPR son comparados con los obtenidos para L-Alanina irradiada con fotones de una fuente radiactiva calibrada (Co60), seg\u00fan las Normas ISO\/ASTM51607-04 e ISO\/ASTM51939-05. Mostramos que este m\u00e9todo dosim\u00e9trico es preciso, reproducible y confiable, como registro de operaci\u00f3n de Reactores para Investigaci\u00f3n; y que las dosis estimadas en RA6, mediante el C\u00f3digo Monte Carlo MCNP5 (Los Alamos National Laboratory, USA), resultan sobreestimadas, en todos los casos considerados. EPR Spectroscopy is used to measure the radiation induced paramagnetism in L-Alanine crystalline powder, irradiated in different cells of the RA6 Nuclear Research Reactor, at the Centro Atomico Bariloche\/CNEA, Bariloche, RN, Argentina. The EPR spectra are compared against those obtained by irradiating L-Alanine with a Calibrated Co60 Source (ISO\/ASTM51607-04). We show that L-Alanine\/EPR Metrology is, accurate and reliable, and that can be used with advantage as a permanent record of the overall performance of Nuclear Research Reactors within the limitations of the Standard Practice ISO\/ASTM51607-04 and ISO\/ASTM51939-05. Within those limits, our data suggest that the values of Dose for the different cells, estimated using the Code MCNP5 (Los Alamos National Laboratory, USA) are, in all cases, overestimated. - 2013-01 Documento de trabajo NonPeerReviewed application\/msword http:\/\/ricabib.cab.cnea.gov.ar\/386\/1\/2013.0108.RA6.Trabajo.Metrologia.doc es Fainstein, Carlos (2013) Metrolog\u00eda de Radiaciones en Reactores EPR\/L-Alanina \/ EPR\/Alanine in RA6 Nuclear Reactor. Informe T\u00e9cnico. -. (No publicado) http:\/\/ricabib.cab.cnea.gov.ar\/386\/"
    ],
    "institution": [
        "Instituto Balseiro"
    ],
    "institution_str": "I-25",
    "repository_str": "R-131",
    "collection": [
        "Repositorio Institucional Centro At\u00f3mico Bariloche e Instituto Balseiro (RICABIB)"
    ],
    "language": [
        "Espa\u00f1ol"
    ],
    "orig_language_str_mv": [
        "es"
    ],
    "topic": [
        "Biolog\u00eda",
        "F\u00edsica",
        "Diagn\u00f3stico por imagen y medicina nuclear",
        "EPR spectrometers",
        "Espectr\u00f3metros RPE",
        "Spectroscopy",
        "Espectroscopia",
        "Paramagnetism",
        "Paramagnetismo",
        "Ionizing radiations",
        "RA-6 reactor",
        "Reactor RA-6",
        "Argentine CNEA",
        "CNEA argentina",
        "Alanine-l",
        "Alanina-l",
        "Monte Carlo Method",
        "M\u00e9todo Monte Carlo"
    ],
    "spellingShingle": [
        "Biolog\u00eda",
        "F\u00edsica",
        "Diagn\u00f3stico por imagen y medicina nuclear",
        "EPR spectrometers",
        "Espectr\u00f3metros RPE",
        "Spectroscopy",
        "Espectroscopia",
        "Paramagnetism",
        "Paramagnetismo",
        "Ionizing radiations",
        "RA-6 reactor",
        "Reactor RA-6",
        "Argentine CNEA",
        "CNEA argentina",
        "Alanine-l",
        "Alanina-l",
        "Monte Carlo Method",
        "M\u00e9todo Monte Carlo",
        "Fainstein, Carlos",
        "Metrolog\u00eda de Radiaciones en Reactores\r\nEPR\/L-Alanina\r\n"
    ],
    "topic_facet": [
        "Biolog\u00eda",
        "F\u00edsica",
        "Diagn\u00f3stico por imagen y medicina nuclear",
        "EPR spectrometers",
        "Espectr\u00f3metros RPE",
        "Spectroscopy",
        "Espectroscopia",
        "Paramagnetism",
        "Paramagnetismo",
        "Ionizing radiations",
        "RA-6 reactor",
        "Reactor RA-6",
        "Argentine CNEA",
        "CNEA argentina",
        "Alanine-l",
        "Alanina-l",
        "Monte Carlo Method",
        "M\u00e9todo Monte Carlo"
    ],
    "description": "Mediante Espectrometr\u00eda EPR medimos el paramagnetismo inducido, por radiaci\u00f3n ionizante, en polvo cristalino de L-Alanina, irradiado en diferentes celdas del n\u00facleo del Reactor de Investigaci\u00f3n RA6 (Centro At\u00f3mico Bariloche\/CNEA, Argentina). \r\nLos espectros EPR son comparados con los obtenidos para L-Alanina irradiada con fotones de una fuente radiactiva calibrada (Co60), seg\u00fan las Normas ISO\/ASTM51607-04 e ISO\/ASTM51939-05.\r\nMostramos que este m\u00e9todo dosim\u00e9trico es preciso, reproducible y confiable, como registro de operaci\u00f3n de Reactores para Investigaci\u00f3n; y que las dosis estimadas en RA6, mediante el C\u00f3digo Monte Carlo MCNP5 (Los Alamos National Laboratory, USA), resultan sobreestimadas, en todos los casos considerados.\r\n",
    "format": [
        "Documento de trabajo",
        "NonPeerReviewed"
    ],
    "author": [
        "Fainstein, Carlos"
    ],
    "author_facet": [
        "Fainstein, Carlos"
    ],
    "author_sort": "Fainstein, Carlos",
    "title": "Metrolog\u00eda de Radiaciones en Reactores\r\nEPR\/L-Alanina\r\n",
    "title_short": "Metrolog\u00eda de Radiaciones en Reactores\r\nEPR\/L-Alanina\r\n",
    "title_full": "Metrolog\u00eda de Radiaciones en Reactores\r\nEPR\/L-Alanina\r\n",
    "title_fullStr": "Metrolog\u00eda de Radiaciones en Reactores\r\nEPR\/L-Alanina\r\n",
    "title_full_unstemmed": "Metrolog\u00eda de Radiaciones en Reactores\r\nEPR\/L-Alanina\r\n",
    "title_sort": "metrolog\u00eda de radiaciones en reactores\r\nepr\/l-alanina",
    "publisher": [
        "-"
    ],
    "publishDate": [
        "2013"
    ],
    "url": [
        "http:\/\/ricabib.cab.cnea.gov.ar\/386\/1\/2013.0108.RA6.Trabajo.Metrologia.doc"
    ],
    "work_keys_str_mv": [
        "AT fainsteincarlos metrologiaderadiacionesenreactoreseprlalanina"
    ],
    "_version_": 1794277770331684864
}